arXiv:quant-ph/9909019 · Journal of Modern Optics

Comparisons of spectra determined using detector atoms and spatial correlation functions

M. Havukainen

Published Jun 1, 2000• 0 citations
arXivHTMLPDF

Abstract

We show how two level atoms can be used to determine the local time dependent spectrum. The method is used in a one-dimensional cavity. The spectrum obtained is compared with the mode spectrum determined using spatially filtered second-order correlation functions. The spectra obtained using two level atoms give identical results with the mode spectrum. One benefit of the method is that only one time averages are needed. It is closely related to a realistic spectrum measurement.

DOI
10.1080/09500340008232165

Related papers

Comparisons of spectra determined using detector atoms and spatial correlation functions

Martti Havukainen

We show how two level atoms can be used to determine the local time dependent spectrum. The method is used in a one-dimensional cavity. The spectrum obtained is compared with the mode spectrum determined using spatially filtered second-order correlation functions. The spectra obtained using two level atoms give identical results with the mode spectrum. One benefit of the method is that only one time averages are needed. It is closely related to a realistic spectrum measurement.

Journal of Modern Optics•Jun 15, 2000•0 citations

Comparisons of spectra determined using detector atoms and spatial correlation functions

Havukainen, M

We show how two level atoms can be used to determine the local time dependent spectrum. The method is applied to a one dimensional cavity. The spectrum obtained is compared with the mode spectrum determined using spatially filtered second order correlation functions. The spectra obtained using two level atoms give identical results with the mode spectrum. One benefit of the method is that only one time averages are needed. It is also more closely related to a realistic measurement scheme than any other definition of a time dependent spectrum.

•Sep 7, 1999•0 citations

Exact results for the emission from one and two atoms in an ideal cavity at multiphoton resonance

Fam Le Kien, A.S. Shumovsky, T Quang

The authors examine the emission from the systems of one or two two-level atoms in an ideal cavity with one mode at multiphoton resonance. Exact results for the two-time dipole correlation function and the time-dependent spectra of multiphoton-induced fluorescence are presented.

Journal of Physics A Mathematical and General•Jan 7, 1988•14 citations

An open systems approach to calculating time dependent spectra

Havukainen, M, Stig Stenholm

A new method to calculate the spectrum using cascaded open systems and master equations is presented. The method uses two state analyzer atoms which are coupled to the system of interest, whose spectrum of radiation is read from the excitation of these analyzer atoms. The ordinary definitions of a spectrum uses two-time averages and Fourier-transforms. The present method uses only one-time averages. The method can be used to calculate time dependent as well as stationary spectra.

•Sep 30, 1997•4 citations

An open-systems approach to calculating time-dependent spectra

Martti Havukainen, Stig Stenholm

A new method to calculate the spectrum using cascaded open systems and a master equation is presented. The method uses two-state analyser atoms which are coupled to the system of interest, whose spectrum of radiation is read from the excitation of these analyser atoms. The ordinary definitions of a spectrum uses two-time averages and Fourier transforms. The present method uses only one-time averages. The method can be used to calculate time-dependent as well as stationary spectra.

Journal of Modern Optics•Aug 1, 1998•0 citations

An open-systems approach to calculating time-dependent spectra

Martti Havukainen, Stig Stenholm

A new method to calculate the spectrum using cascaded open systems and a master equation is presented. The method uses two-state analyser atoms which are coupled to the system of interest, whose spectrum of radiation is read from the excitation of these analyser atoms. The ordinary definitions of a spectrum uses two-time averages and Fourier transforms. The present method uses only one-time averages. The method can be used to calculate time-dependent as well as stationary spectra.

arXiv:quant-ph/9709054•Journal of Modern Optics•Aug 1, 1998•5 citations
We show how two level atoms can be used to determine the local time dependent spectrum. The method is used in a one-dimensional cavity. The spectrum obtained is compared with the mode spectrum determined using spatially filtered second-order correlation functions. The spectra obtained using two level atoms give identical results with the mode spectrum. One benefit of the method is that only one time averages are needed. It is closely related to a realistic spectrum measurement.
We show how two level atoms can be used to determine the local time dependent spectrum. The method is applied to a one dimensional cavity. The spectrum obtained is compared with the mode spectrum determined using spatially filtered second order correlation functions. The spectra obtained using two level atoms give identical results with the mode spectrum. One benefit of the method is that only one time averages are needed. It is also more closely related to a realistic measurement scheme than any other definition of a time dependent spectrum.