Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/9705025

The Quantum Tomographic Roulette Wheel

Giacomo Mauro D’Ariano, Matteo G. A. Paris

Published May 13, 1997• 0 citations
arXivHTMLPDF

Abstract

Random-phase homodyne tomography of the field intensity is a concrete example of the Quantum Roulette of Helstrom. In this paper we give the explicit POM of such measurement and compare it with direct photodetection and heterodyne detection. Effects of nonunit quantum efficiency are also considered. Naimark extensions for the roulette POM are analyzed and its experimental realization is discussed.

DOI
10.48550/arxiv.quant-ph/9705025

Related papers

Homodyning as Universal Detection

Giacomo Mauro D’Ariano

Homodyne tomography - i. e. homodyning while scanning the local oscillator phase - is now a well assessed method for ``measuring'' the quantum state. In this paper I will show how it can be used as a kind of universal detection, for measuring generic field operators, however at expense of some additional noise. The general class of field operators that can be measured in this way is presented, and includes also operators that are inaccessible to heterodyne detection. The noise from tomographical homodyning is compared to that from heterodyning, for those operators that can be measured in both ways. It turns out that for some operators homodyning is better than heterodyning when the mean photon number is sufficiently small. Finally, the robustness of the method to additive phase-insensitive noise is analyzed. It is shown that just half photon of thermal noise would spoil the measurement completely.

arXiv:quant-ph/9701011•WORLD SCIENTIFIC eBooks•Feb 1, 2005•0 citations

Homodyning and heterodyning the quantum phase

Giacomo Mauro D’Ariano, Chiara Macchiavello, Matteo G. A. Paris

The double-homodyne and the heterodyne detection schemes for phase shifts between two synchronous modes of the electromagnetic field are analyzed in the framework of quantum estimation theory. The probability operator-valued measures (POM's) of the detectors are evaluated and compared with the ideal one in the limit of strong local reference oscillator. The present operational approach leads to a reasonable definition of phase measurement, whose sensitivity is actually related to the output r.m.s. noise of the photodetector. We emphasize that the simple-homodyne scheme does not correspond to a proper phase-shift measurements as it is just a zero-point detector. The sensitivity of all detection schemes are optimized at fixed energy with respect to the input state of radiation. It is shown that the optimal sensitivity can be actually achieved using suited squeezed states.

•May 1, 1994•0 citations

Realistic Measurement of Phase

Henryk Paul, Ulf Leonhardt

The experimental schemes for measuring quantum-mechanical phase properties of light suggested and partly also realized thus far, namely (i) amplification, with the help of a quantum amplifier, of the microscopic field before phase measurement, (ii) heterodyning the field with a strong local oscillator, and (iii) performing two separate homodyne measurements on the field after beam splitting, are compared from a theoretical point of view.They share the common feature that undesired noise enters the experimental setup, which makes the measurement fuzzy.It will be pointed out that all three schemes amount to measuring the Q function of the original field, and hence are fully equivalent.Since the Q function can be interpreted as a smoothed Wigner function, one may associate with the introduced noise a smoothing process in which intrinsically quantum-mechanical features displayed by finer details of the Wigner function -especially by the occurrence of negative values -are lost.As a consequence, the measured phase distribution will be broader than the "true" one based on the concept of a quantum-mechanical phase operator.In realistic experiments, the nonunit detection efficiency further deteriorates the measuring results.It will be shown that also this echect can be properly described by an (additional) smoothing process leading to a certain s-parametrized quasiprobability distribution, with a parameter s that is connected with the detection efficiency in a simple way, as the distribution that is actually measurable.

Acta Physica Polonica A•Jul 1, 1994•3 citations

Overcoming Vacuum Noise: The Unforeseen Benefits of Quantum Heterodyne Detection

C. R. Müller, Christian Peuntinger, Thomas Dirmeier +8 more

Homodyne tomography and heterodyne detection are principal measurement schemes in continuous-variable quantum information and provide different accuracies in determining the quantum state of a system. The former allows for a tomographic reconstruction of the Wigner function of the state, whereas the latter directly samples its Husimi Q-function. We experimentally demonstrate that contrary to a common belief, heterodyne detection outperforms homodyne tomography for almost all Gaussian states.

Frontiers in Optics•Jan 1, 2016•0 citations

Direct Probing of Quantum Phase Space by Photon Counting

Konrad Banaszek, K. Wódkiewicz

We propose a very simple experimental setup to measure, via photon counting, the overlap of the Wigner functions characterizing two single mode light beams. We show that this scheme can be applied to determine directly the phase space quasiprobability distribution of the single mode field and in a certain limit the Wigner function can be measured without use of tomographic reconstruction algorithms. The deleterious effects of nonunit photodetector efficiency are analyzed.

arXiv:atom-ph/9603003•Physical Review Letters•Jun 3, 1996•340 citations

Pulsed homodyne Gaussian quantum tomography with low detection efficiency

Martina Esposito, Fabio Benatti, Roberto Floreanini B +8 more

Pulsed homodyne quantum tomography usually requires a high detection efficiency, limiting its applicability in quantum optics. Here, it is shown that the presence of low detection efficiency (<50%) does not prevent the tomographic reconstruction of quantum states of light, specifically, of Gaussian states. This result is obtained by applying the so-called minimax adaptive reconstruction of the Wigner function to pulsed homodyne detection. In particular, we prove, by both numerical and real experiments, that an effective discrimination of different Gaussian quantum states can be achieved. Our finding paves the way to a more extensive use of quantum tomographic methods, even in physical situations in which high detection efficiency is unattainable.

•Jan 1, 2024•20 citations
Random-phase homodyne tomography of the field intensity is a concrete example of the Quantum Roulette of Helstrom. In this paper we give the explicit POM of such measurement and compare it with direct photodetection and heterodyne detection. Effects of nonunit quantum efficiency are also considered. Naimark extensions for the roulette POM are analyzed and its experimental realization is discussed.
Homodyne tomography - i. e. homodyning while scanning the local oscillator phase - is now a well assessed method for ``measuring'' the quantum state. In this paper I will show how it can be used as a kind of universal detection, for measuring generic field operators, however at expense of some additional noise. The general class of field operators that can be measured in this way is presented, and includes also operators that are inaccessible to heterodyne detection. The noise from tomographical homodyning is compared to that from heterodyning, for those operators that can be measured in both ways. It turns out that for some operators homodyning is better than heterodyning when the mean photon number is sufficiently small. Finally, the robustness of the method to additive phase-insensitive noise is analyzed. It is shown that just half photon of thermal noise would spoil the measurement completely.
The double-homodyne and the heterodyne detection schemes for phase shifts between two synchronous modes of the electromagnetic field are analyzed in the framework of quantum estimation theory. The probability operator-valued measures (POM's) of the detectors are evaluated and compared with the ideal one in the limit of strong local reference oscillator. The present operational approach leads to a reasonable definition of phase measurement, whose sensitivity is actually related to the output r.m.s. noise of the photodetector. We emphasize that the simple-homodyne scheme does not correspond to a proper phase-shift measurements as it is just a zero-point detector. The sensitivity of all detection schemes are optimized at fixed energy with respect to the input state of radiation. It is shown that the optimal sensitivity can be actually achieved using suited squeezed states.
The experimental schemes for measuring quantum-mechanical phase properties of light suggested and partly also realized thus far, namely (i) amplification, with the help of a quantum amplifier, of the microscopic field before phase measurement, (ii) heterodyning the field with a strong local oscillator, and (iii) performing two separate homodyne measurements on the field after beam splitting, are compared from a theoretical point of view.They share the common feature that undesired noise enters the experimental setup, which makes the measurement fuzzy.It will be pointed out that all three schemes amount to measuring the Q function of the original field, and hence are fully equivalent.Since the Q function can be interpreted as a smoothed Wigner function, one may associate with the introduced noise a smoothing process in which intrinsically quantum-mechanical features displayed by finer details of the Wigner function -especially by the occurrence of negative values -are lost.As a consequence, the measured phase distribution will be broader than the "true" one based on the concept of a quantum-mechanical phase operator.In realistic experiments, the nonunit detection efficiency further deteriorates the measuring results.It will be shown that also this echect can be properly described by an (additional) smoothing process leading to a certain s-parametrized quasiprobability distribution, with a parameter s that is connected with the detection efficiency in a simple way, as the distribution that is actually measurable.
Pulsed homodyne quantum tomography usually requires a high detection efficiency, limiting its applicability in quantum optics. Here, it is shown that the presence of low detection efficiency (<50%) does not prevent the tomographic reconstruction of quantum states of light, specifically, of Gaussian states. This result is obtained by applying the so-called minimax adaptive reconstruction of the Wigner function to pulsed homodyne detection. In particular, we prove, by both numerical and real experiments, that an effective discrimination of different Gaussian quantum states can be achieved. Our finding paves the way to a more extensive use of quantum tomographic methods, even in physical situations in which high detection efficiency is unattainable.