Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/9603030 · Physical Review A

Homodyne detection for measuring internal quantum correlations of optical pulses

Tomáš Opatrný, D.‐G. Welsch, W. Vogel

Published Feb 1, 1997• 26 citations
arXivHTMLPDF

Abstract

A method is described for determining the quantum correlations at different times in optical pulses by using balanced homodyne detection. The signal pulse and sequences of ultrashort test pulses (local oscillators) are superimposed, where for chosen distances between the test pulses their relative phases and intensities are varied from measurement to measurement. The correlation statistics of the signal pulse is obtained from the time-integrated difference photocurrents measured.

DOI
10.1103/physreva.55.1416

Related papers

Ultrafast measurement of optical-field statistics by dc-balanced homodyne detection

Michael G. Raymer, J. Cooper, H. J. Carmichael +2 more

The technique of dc-balanced, pulsed homodyne detection for the purpose of determining optical-field statistics on short time scales is analyzed theoretically. Such measurements provide photon-number and phase distributions associated with a repetitive signal light field in a short time window. Time- and space-varying signal and local-oscillator pulses are treated, thus generalizing earlier treatments of photoelectron difference statistics in homodyne detection. Experimental issues, such as the effects of imperfect detector balancing on (time-integrated) dc detection and the consequences of background noise caused by non-mode-matched parts of the multimode signal field, are analyzed. The Wigner, or joint, distribution for the two field-quadrature amplitudes during the sampling time window can be directly determined by tomographic inversion of the measured photoelectron distributions. It is pointed out that homodyne detection provides a new method for the simultaneous measurement of temporal and spectral information. Although the theory is generally formulated, with both signal and local-oscillator fields being quantized, emphasis is placed on the limit of a strong, coherent local-oscillator field, making semiclassical interpretation possible.

Journal of the Optical Society of America B•Oct 1, 1995•88 citations

Homodyne-like detection scheme based on photon-number-resolving detectors

Alessia Allevi, Matteo Bina, Stefano Olivares +1 more

Homodyne detection is the most effective detection scheme employed in quantum optics to characterize quantum states. It is based on mixing at a beam splitter the signal to be measured with a coherent state, called the “local oscillator,” and on evaluating the difference of the photocurrents of two photodiodes measuring the outputs of the beam splitter. If the local oscillator is much more intense than the field to be measured, the homodyne signal is proportional to the signal-field quadratures. If the local oscillator is less intense, the photodiodes can be replaced with photon-number-resolving detectors, which have a smaller dynamics but can measure the light statistics. The resulting new homodyne-like detector acquires a hybrid nature, being it capable of yielding information on both the particle-like (statistics) and wave-like (phase) properties of light signals. The scheme has been tested in the measurement of the quadratures of coherent states, bracket states and phase-averaged coherent states at different intensities of the local oscillator.

International Journal of Quantum Information•Dec 1, 2017•13 citations

High-stability time-domain balanced homodyne detector for ultrafast optical pulse applications

Merlin Cooper, Christoph Söller, Brian J. Smith

Low-noise, efficient, phase-sensitive time-domain optical detection is essential for foundational tests of quantum physics based on optical quantum states and the realization of numerous applications ranging from quantum key distribution to coherent classical telecommunications. Stability, bandwidth, efficiency, and signal-to-noise ratio are crucial performance parameters for effective detector operation. Here we present a high-bandwidth, low-noise, ultra-stable time-domain coherent measurement scheme based on balanced homodyne detection ideally suited to characterization of quantum and classical light fields in well-defined ultrashort optical pulse modes.

arXiv:1112.0875•Journal of Modern Optics•May 1, 2013•29 citations

Fast time-domain balanced homodyne detection of light

Ondřej Haderka, Václav Michálek, Vladimir Urbasek +1 more

A balanced homodyne detection scheme with nanosecond time resolution and sub-shot-noise sensitivity has been developed and successfully tested yielding an efficient detection scheme for high-speed quantum-optical measurements and communication protocols, for example, quantum cryptography. The parameters of the detector and its precise balancing allow complete characterization of quantum states created by femtosecond light pulses that include the measurement of photon number, optical phase, and statistical properties with a high signal-to-noise ratio for the whole bandwidth from DC to several tens of megahertz. The electronic part of the detector is based on a commercially available amplifier that provides ease of construction and use while yielding good performance.

Applied Optics•May 13, 2009•33 citations

Correlation and joint density matrix of two spatial-temporal modes from balanced-homodyne sampling

D. F. McAlister, Michael G. Raymer

A theoretical treatment is given which establishes dual-mode balanced-homodyne detection as a practical and well characterized technique for measuring optical field correlations, photon-number correlations, or the full quantum state of a pair of optical modes. The definition of modes used includes temporal wave packets, Gaussian or other beam profiles, or two-frequency fields. The proposed method allows the measurement of two-time correlations on sub-picosecond scales, the disentangling of the statistics of signal light in two spatially overlapping modes, and the measurement of field correlations, such as squeezing, over 100 THz bandwidths. We show how to estimate from the data the statistical errors on the measured correlations and the density matrix arising from finite data sets, and the errors introduced by using finite numbers of phases and relative amplitudes of the two local oscillator fields.

Journal of Modern Optics•Nov 1, 1997•13 citations

Ultrafast photon-number correlations from dual-pulse, phase-averaged homodyne detection

D. F. McAlister, Michael G. Raymer

We propose and demonstrate a method for determining the two-time photon-number correlations of an optical field on ultrafast time scales. The method, which uses dual-pulse, phase-averaged, balanced-homodyne detection, is sensitive at the single-photon level and can have a quantum efficiency approaching 100%. Using this method we have determined the two-time, photon-number correlations on subpicosecond time scales of emission from a semiconductor optical amplifier.

Physical Review A•Mar 1, 1997•70 citations
A method is described for determining the quantum correlations at different times in optical pulses by using balanced homodyne detection. The signal pulse and sequences of ultrashort test pulses (local oscillators) are superimposed, where for chosen distances between the test pulses their relative phases and intensities are varied from measurement to measurement. The correlation statistics of the signal pulse is obtained from the time-integrated difference photocurrents measured.
The technique of dc-balanced, pulsed homodyne detection for the purpose of determining optical-field statistics on short time scales is analyzed theoretically. Such measurements provide photon-number and phase distributions associated with a repetitive signal light field in a short time window. Time- and space-varying signal and local-oscillator pulses are treated, thus generalizing earlier treatments of photoelectron difference statistics in homodyne detection. Experimental issues, such as the effects of imperfect detector balancing on (time-integrated) dc detection and the consequences of background noise caused by non-mode-matched parts of the multimode signal field, are analyzed. The Wigner, or joint, distribution for the two field-quadrature amplitudes during the sampling time window can be directly determined by tomographic inversion of the measured photoelectron distributions. It is pointed out that homodyne detection provides a new method for the simultaneous measurement of temporal and spectral information. Although the theory is generally formulated, with both signal and local-oscillator fields being quantized, emphasis is placed on the limit of a strong, coherent local-oscillator field, making semiclassical interpretation possible.
Homodyne detection is the most effective detection scheme employed in quantum optics to characterize quantum states. It is based on mixing at a beam splitter the signal to be measured with a coherent state, called the “local oscillator,” and on evaluating the difference of the photocurrents of two photodiodes measuring the outputs of the beam splitter. If the local oscillator is much more intense than the field to be measured, the homodyne signal is proportional to the signal-field quadratures. If the local oscillator is less intense, the photodiodes can be replaced with photon-number-resolving detectors, which have a smaller dynamics but can measure the light statistics. The resulting new homodyne-like detector acquires a hybrid nature, being it capable of yielding information on both the particle-like (statistics) and wave-like (phase) properties of light signals. The scheme has been tested in the measurement of the quadratures of coherent states, bracket states and phase-averaged coherent states at different intensities of the local oscillator.
Low-noise, efficient, phase-sensitive time-domain optical detection is essential for foundational tests of quantum physics based on optical quantum states and the realization of numerous applications ranging from quantum key distribution to coherent classical telecommunications. Stability, bandwidth, efficiency, and signal-to-noise ratio are crucial performance parameters for effective detector operation. Here we present a high-bandwidth, low-noise, ultra-stable time-domain coherent measurement scheme based on balanced homodyne detection ideally suited to characterization of quantum and classical light fields in well-defined ultrashort optical pulse modes.
A balanced homodyne detection scheme with nanosecond time resolution and sub-shot-noise sensitivity has been developed and successfully tested yielding an efficient detection scheme for high-speed quantum-optical measurements and communication protocols, for example, quantum cryptography. The parameters of the detector and its precise balancing allow complete characterization of quantum states created by femtosecond light pulses that include the measurement of photon number, optical phase, and statistical properties with a high signal-to-noise ratio for the whole bandwidth from DC to several tens of megahertz. The electronic part of the detector is based on a commercially available amplifier that provides ease of construction and use while yielding good performance.
A theoretical treatment is given which establishes dual-mode balanced-homodyne detection as a practical and well characterized technique for measuring optical field correlations, photon-number correlations, or the full quantum state of a pair of optical modes. The definition of modes used includes temporal wave packets, Gaussian or other beam profiles, or two-frequency fields. The proposed method allows the measurement of two-time correlations on sub-picosecond scales, the disentangling of the statistics of signal light in two spatially overlapping modes, and the measurement of field correlations, such as squeezing, over 100 THz bandwidths. We show how to estimate from the data the statistical errors on the measured correlations and the density matrix arising from finite data sets, and the errors introduced by using finite numbers of phases and relative amplitudes of the two local oscillator fields.