Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1112.0875 · Journal of Modern Optics

High-stability time-domain balanced homodyne detector for ultrafast optical pulse applications

Merlin Cooper, Christoph Söller, Brian J. Smith

Published May 1, 2013• 29 citations
arXivHTMLPDF

Abstract

Low-noise, efficient, phase-sensitive time-domain optical detection is essential for foundational tests of quantum physics based on optical quantum states and the realization of numerous applications ranging from quantum key distribution to coherent classical telecommunications. Stability, bandwidth, efficiency, and signal-to-noise ratio are crucial performance parameters for effective detector operation. Here we present a high-bandwidth, low-noise, ultra-stable time-domain coherent measurement scheme based on balanced homodyne detection ideally suited to characterization of quantum and classical light fields in well-defined ultrashort optical pulse modes.

DOI
10.1080/09500340.2013.797612

Related papers

Fast time-domain balanced homodyne detection of light

Ondřej Haderka, Václav Michálek, Vladimir Urbasek +1 more

A balanced homodyne detection scheme with nanosecond time resolution and sub-shot-noise sensitivity has been developed and successfully tested yielding an efficient detection scheme for high-speed quantum-optical measurements and communication protocols, for example, quantum cryptography. The parameters of the detector and its precise balancing allow complete characterization of quantum states created by femtosecond light pulses that include the measurement of photon number, optical phase, and statistical properties with a high signal-to-noise ratio for the whole bandwidth from DC to several tens of megahertz. The electronic part of the detector is based on a commercially available amplifier that provides ease of construction and use while yielding good performance.

Applied Optics•May 13, 2009•33 citations

High-speed time-domain balanced homodyne detector for nanosecond optical field applications

Shanna Du, Zongyang Li, Wenyuan Liu +2 more

We present a high-speed time-domain shot-noise-limited balanced homodyne detector that is suitable for the detection of the quantum states of nanosecond pulsed optical fields. The detector can detect the quantum noise of individual nanosecond optical pulses at a repetition rate of 40 MHz and achieve a signal-to-noise ratio of above 14.5 dB at a local oscillator power of 9.9×107 photons per pulse. The stability of the detector is characterized via an Allan variance measurement, and superior stability is observed. The detector is especially applicable in the fields of quantum optics and quantum information, where high-speed time-domain detection of nanosecond pulsed optical field quadratures is required.

Journal of the Optical Society of America B•Feb 1, 2018•19 citations

Design and characterization of wideband balanced homodyne detectors for quantum homodyne tomography

Erick Barrios Barocio

This thesis reports the realization and applications of a versatile wideband balanced homodyne detector operating in the time domain and intended for Quantum Optical Tomography. The detector can work with high repetition rate lasers used for the production and measurement of the electric field quadratures of quantum states of light. Full characterization of the detector by shot-noise measurements and by verifying its capability to reconstruct the density matrix and Wigner function of various states of interest is given. By overcoming photodiodes response mismatch, high frequency electronics issues and by choosing an appropriate optical set-up, a high level of common mode suppression (52.4dB) and a low electronic noise gave a shot-to-electronic noise ratio of I3dB for a Local Oscillator with 6.2 x 108 photons-per-pulse on a ~ 100MHz bandwidth. Results for the characterization of a single-photon Fock state are presented. An average efficiency of 56% was obtained for the generation/detection of the state.

•Jan 1, 2012•0 citations

High-stability Time-domain Balanced Homodyne Detector for Ultrafast Optical Pulse Applications

Merlin Cooper, Christoph Soeller, Brian J. Smith

We present a broadband high-efficiency balanced homodyne detector exhibiting unparalleled stability and signal-to-noise characteristics. Quantum state tomography of a weak coherent state demonstrates the detector capability in the quantum regime.

Conference on Lasers and Electro-Optics•Jan 1, 2012•8 citations

Quantum tomography for time domain Balanced Homodyne Detection with high electronic noise

Martina Esposito, Daniele Fausti, Stefano Olivares +6 more

Here we report on the design, construction and characterization of a time domain Balanced Homodyne Detection apparatus operating in the regime of high electronic noise. The experimental setup has been commissioned by studying coherent ultrashort ( ∼ 80 fs) light pulses using Pattern-function Quantum Tomography. Furthermore, we proved that the electronic noise can be treated as a detector inefficiency showing the effectiveness of this approach by measuring light coherent states with different energies. In Quantum Mechanics the measurement of the state of a physical system implies to estimate the expectation value of any observable of the system. For a generic operator the expectation value is obtained starting from the measurement of an ensemble of observables defined “quorum ” 1. In particular, for the electromagnetic field the quorum is a continuum set of the field quadra-tures2,3. Balanced Homodyne Detection (BHD) is an experimen-tal method for measuring a discrete set of the field

•Jan 11, 2013•1 citation

A Simple and Robust Balanced Homodyne Detector for High-Repetition-Rate Pulsed Sources

Samuele Altilia, Edoardo Suerra, Pietro Puppi +3 more

We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.

physics.opticsCross-listedarXiv:2604.06994•Apr 9, 2026•0 citations
Low-noise, efficient, phase-sensitive time-domain optical detection is essential for foundational tests of quantum physics based on optical quantum states and the realization of numerous applications ranging from quantum key distribution to coherent classical telecommunications. Stability, bandwidth, efficiency, and signal-to-noise ratio are crucial performance parameters for effective detector operation. Here we present a high-bandwidth, low-noise, ultra-stable time-domain coherent measurement scheme based on balanced homodyne detection ideally suited to characterization of quantum and classical light fields in well-defined ultrashort optical pulse modes.
A balanced homodyne detection scheme with nanosecond time resolution and sub-shot-noise sensitivity has been developed and successfully tested yielding an efficient detection scheme for high-speed quantum-optical measurements and communication protocols, for example, quantum cryptography. The parameters of the detector and its precise balancing allow complete characterization of quantum states created by femtosecond light pulses that include the measurement of photon number, optical phase, and statistical properties with a high signal-to-noise ratio for the whole bandwidth from DC to several tens of megahertz. The electronic part of the detector is based on a commercially available amplifier that provides ease of construction and use while yielding good performance.
We present a high-speed time-domain shot-noise-limited balanced homodyne detector that is suitable for the detection of the quantum states of nanosecond pulsed optical fields. The detector can detect the quantum noise of individual nanosecond optical pulses at a repetition rate of 40 MHz and achieve a signal-to-noise ratio of above 14.5 dB at a local oscillator power of 9.9×107 photons per pulse. The stability of the detector is characterized via an Allan variance measurement, and superior stability is observed. The detector is especially applicable in the fields of quantum optics and quantum information, where high-speed time-domain detection of nanosecond pulsed optical field quadratures is required.
This thesis reports the realization and applications of a versatile wideband balanced homodyne detector operating in the time domain and intended for Quantum Optical Tomography. The detector can work with high repetition rate lasers used for the production and measurement of the electric field quadratures of quantum states of light. Full characterization of the detector by shot-noise measurements and by verifying its capability to reconstruct the density matrix and Wigner function of various states of interest is given. By overcoming photodiodes response mismatch, high frequency electronics issues and by choosing an appropriate optical set-up, a high level of common mode suppression (52.4dB) and a low electronic noise gave a shot-to-electronic noise ratio of I3dB for a Local Oscillator with 6.2 x 108 photons-per-pulse on a ~ 100MHz bandwidth. Results for the characterization of a single-photon Fock state are presented. An average efficiency of 56% was obtained for the generation/detection of the state.
Here we report on the design, construction and characterization of a time domain Balanced Homodyne Detection apparatus operating in the regime of high electronic noise. The experimental setup has been commissioned by studying coherent ultrashort ( ∼ 80 fs) light pulses using Pattern-function Quantum Tomography. Furthermore, we proved that the electronic noise can be treated as a detector inefficiency showing the effectiveness of this approach by measuring light coherent states with different energies. In Quantum Mechanics the measurement of the state of a physical system implies to estimate the expectation value of any observable of the system. For a generic operator the expectation value is obtained starting from the measurement of an ensemble of observables defined “quorum ” 1. In particular, for the electromagnetic field the quorum is a continuum set of the field quadra-tures2,3. Balanced Homodyne Detection (BHD) is an experimen-tal method for measuring a discrete set of the field
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.