Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0702139 · Optics Express

Observation of -9 dB quadrature squeezing with improvement of phase stability in homodyne measurement

Yuishi Takeno, Mitsuyoshi Yukawa, Hidehiro Yonezawa, Akira Furusawa

Published Jan 1, 2007• 259 citations
arXivHTMLPDF

Abstract

We observe -9.01+/-0.14 dB of squeezing and +15.12+/-0.14 dB of antisqueezing with a local oscillator phase locked in homodyne measurement. Suzuki et al. have pointed out two main factors in [Appl. Phys. Lett. 89, 061116 (2006)], which degrade the observed squeezing level:phase fluctuation in homodyne measurement and intracavity losses of an optical parametric oscillator for squeezing. We have improved the phase stability of homodyne measurement and have reduced the intracavity losses. We measure pump power dependences of the squeezing and antisqueezing levels, which show good agreement with theoretical calculations taking account of the phase fluctuation.

DOI
10.1364/oe.15.004321

Related papers

Observation of -9 dB quadrature squeezing with improvement of phase stability in homodyne measurement

Takeno, Y, Furusawa, A, Hidehiro Yonezawa +1 more

We observe -9.01$\\pm$0.14 dB of squeezing and +15.12$\\pm$0.14 dB of antisqueezing with a local oscillator phase locked in homodyne measurement. In reference [1], two main factors are pointed out which degrade the observed squeezing level: phase fluctuation in homodyne measurement and intracavity losses of an optical parametric oscillator for squeezing. We have improved the phase stability of homodyne measurement and have reduced the intracavity losses. We measure pump power dependences of the squeezing and antisqueezing levels, which show good agreement with theoretical calculations taking account of the phase fluctuation.

•Feb 14, 2007•157 citations

7 dB quadrature squeezing at 860 nm with periodically-poled KTiOPO4

Shigenari Suzuki, Hidehiro Yonezawa, Fumihiko Kannari +2 more

We observed -7.2 dB quadrature squeezing at 860 nm by using a sub-threshold continuous-wave pumped optical parametric oscillator with a periodically-poled KTiOPO4 crystal as a nonlinear optical medium. The squeezing level was measured with the phase of homodyne detection locked at the quadrature. The blue light induced infrared absorption (BLIIRA) was not observed in the experiment. Also, we showed that the squeezing beyond -10 dB could be achieved with feasible experimental parameters.

•Jan 1, 2006•105 citations

7 dB quadrature squeezing at 860nm with periodically poled KTiOPO4

Shigenari Suzuki, Hidehiro Yonezawa, Fumihiko Kannari +2 more

The authors observed −7.2±0.2dB quadrature squeezing at 860nm by using a subthreshold continuous-wave pumped optical parametric oscillator with a periodically poled KTiOPO4 crystal as a nonlinear optical medium. The squeezing level was measured with the phase of homodyne detection locked at the quadrature. The blue light induced infrared absorption was not observed in the experiment.

arXiv:quant-ph/0602036•Applied Physics Letters•Aug 7, 2006•101 citations

Squeezing and antisqueezing in homodyne measurements

M. S. Kim, Barry C. Sanders

Squeezing the signal field or the local oscillator can improve the accuracy of homodyne detection. We show that an equivalence exists between antisqueezing the signal field and squeezing the local oscillator state. The importance of this result is illustrated in two contexts: a homodyne measurement of squeezing and the reconstruction of the wave function. \textcopyright{} 1996 The American Physical Society.

Physical Review A•May 1, 1996•24 citations

Effect of imperfect homodyne visibility on multi-spatial-mode two-mode squeezing measurements

Prasoon Gupta, Rory W. Speirs, K. M. Jones +1 more

We study the effect of homodyne detector visibility on the measurement of quadrature squeezing for a spatially multi-mode source of two-mode squeezed light. Sources like optical parametric oscillators (OPO) typically produce squeezing in a single spatial mode because the nonlinear medium is within a mode-selective optical cavity. For such a source, imperfect interference visibility in the homodyne detector couples in additional vacuum noise, which can be accounted for by introducing an equivalent loss term. In a free-space multi-spatial-mode system imperfect homodyne detector visibility can couple in uncorrelated squeezed modes, and hence can cause faster degradation of the measured squeezing. We show experimentally the dependence of the measured squeezing level on the visibility of homodyne detectors used to probe two-mode squeezed states produced by a free space four-wave mixing process in 85 Rb vapor, and also demonstrate that a simple theoretical model agrees closely with the experimental data.

arXiv:2001.06031•Optics Express•Dec 12, 2019•16 citations

Lifting the bandwidth limit of optical homodyne measurement with broadband parametric amplification

Yaakov Shaked, Yoad Michael, Rafi Z. Vered +3 more

Homodyne measurement is a corner-stone method of quantum optics that measures the quadratures of light-the quantum optical analog of the canonical position and momentum. Standard homodyne, however, suffers from a severe bandwidth limitation: while the bandwidth of optical states can span many THz, standard homodyne is inherently limited to the electronically accessible MHz-to-GHz range, leaving a dramatic gap between relevant optical phenomena and the measurement capability. We demonstrate a fully parallel optical homodyne measurement across an arbitrary optical bandwidth, effectively lifting this bandwidth limitation completely. Using optical parametric amplification, which amplifies one quadrature while attenuating the other, we measure quadrature squeezing of 1.7 dB simultaneously across 55 THz, using the pump as the only local oscillator. As opposed to standard homodyne, our measurement is robust to detection inefficiency, and was obtained with >50% detection loss. Broadband parametric homodyne opens a wide window for parallel processing of quantum information.

Nature Communications•Feb 5, 2018•122 citations
We observe -9.01+/-0.14 dB of squeezing and +15.12+/-0.14 dB of antisqueezing with a local oscillator phase locked in homodyne measurement. Suzuki et al. have pointed out two main factors in [Appl. Phys. Lett. 89, 061116 (2006)], which degrade the observed squeezing level:phase fluctuation in homodyne measurement and intracavity losses of an optical parametric oscillator for squeezing. We have improved the phase stability of homodyne measurement and have reduced the intracavity losses. We measure pump power dependences of the squeezing and antisqueezing levels, which show good agreement with theoretical calculations taking account of the phase fluctuation.
We observe -9.01$\\pm0.14dBofsqueezingand+15.120.14 dB of squeezing and +15.120.14dBofsqueezingand+15.12\\pm$0.14 dB of antisqueezing with a local oscillator phase locked in homodyne measurement. In reference [1], two main factors are pointed out which degrade the observed squeezing level: phase fluctuation in homodyne measurement and intracavity losses of an optical parametric oscillator for squeezing. We have improved the phase stability of homodyne measurement and have reduced the intracavity losses. We measure pump power dependences of the squeezing and antisqueezing levels, which show good agreement with theoretical calculations taking account of the phase fluctuation.
We study the effect of homodyne detector visibility on the measurement of quadrature squeezing for a spatially multi-mode source of two-mode squeezed light. Sources like optical parametric oscillators (OPO) typically produce squeezing in a single spatial mode because the nonlinear medium is within a mode-selective optical cavity. For such a source, imperfect interference visibility in the homodyne detector couples in additional vacuum noise, which can be accounted for by introducing an equivalent loss term. In a free-space multi-spatial-mode system imperfect homodyne detector visibility can couple in uncorrelated squeezed modes, and hence can cause faster degradation of the measured squeezing. We show experimentally the dependence of the measured squeezing level on the visibility of homodyne detectors used to probe two-mode squeezed states produced by a free space four-wave mixing process in 85 Rb vapor, and also demonstrate that a simple theoretical model agrees closely with the experimental data.
Homodyne measurement is a corner-stone method of quantum optics that measures the quadratures of light-the quantum optical analog of the canonical position and momentum. Standard homodyne, however, suffers from a severe bandwidth limitation: while the bandwidth of optical states can span many THz, standard homodyne is inherently limited to the electronically accessible MHz-to-GHz range, leaving a dramatic gap between relevant optical phenomena and the measurement capability. We demonstrate a fully parallel optical homodyne measurement across an arbitrary optical bandwidth, effectively lifting this bandwidth limitation completely. Using optical parametric amplification, which amplifies one quadrature while attenuating the other, we measure quadrature squeezing of 1.7 dB simultaneously across 55 THz, using the pump as the only local oscillator. As opposed to standard homodyne, our measurement is robust to detection inefficiency, and was obtained with >50% detection loss. Broadband parametric homodyne opens a wide window for parallel processing of quantum information.