Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0512033 · Applied Optics

Application of an all-solid-state, frequency-doubled Nd:YAP laser to the generation of twin beams at 1080 nm

Ruixiang Guo, Julien Laurat, Jiangrui Gao, Changde Xie, Kunchi Peng

Published Apr 20, 2002• 8 citations
arXivHTMLPDF

Abstract

A laser-diode-pumped intracavity frequency-doubled Nd:YAP/KTP laser is presented. Over 110 mw of TEM00 single-frequency output power at 540-nm wavelength was obtained. The output green laser was employed to pump a semimonolithic nondegenerate optical parametric oscillator to produce intensity quantum correlated twin beams at 1080 nm, and the maximum quantum noise squeezing of 74% (5.9dB) on the intensity difference fluctuation between the twin beams is observed. The threshold was reduced and the stability was increased significantly when compared with similar lamp-pumped systems.

DOI
10.1364/ao.41.002304

Related papers

Generation of twin beams from an optical parametric oscillator pumped by a frequency-doubled diode laser

Hayasaka, K, Zhang, Y, Kasai, K

Quantum-correlated twin beams were generated from a triply resonant optical parametric oscillator with an a-cut KTP crystal pumped by a frequency-doubled diode laser. A total output of 5.1 mW was obtained in the classical-to-nonclassical-light conversion system driven by a 50-mW diode laser at 1080 nm. Quantum noise reduction of 4.3 dB (63%) in the intensity difference between the twin beams was successfully observed at the detection frequency of 3 MHz.

•Jan 1, 2004•29 citations

Experimental investigation of intensity difference squeezing using Nd:YAP laser as pump source

Qing Pan, Yun Zhang, Tiancai Zhang +2 more

A strong quantum correlation between twin-beams at wavelength was observed. The intensity difference noise of twin-beams, which is generated by a semimonolithic OPO cavity pumped by a frequency-doubled and stabilized Nd:YAP laser, is about 80% (7 dB) below the short noise limit at the measurement frequency of 1.5 MHz. The threshold of the optical parametric oscillator is about 20 mW. The parametric dependence of the quantum correlation is experimentally investigated. The experimental results agree with the theory well.

Journal of Physics D Applied Physics•Jun 7, 1997•12 citations

Generation of twin beams from an optical parametric oscillator pumped by a frequency-doubled diode laser

Kazuhiro Hayasaka, Yun Zhang, Katsuyuki Kasai

Quantum-correlated twin beams were generated from a triply resonant optical parametric oscillator with an a-cut KTP crystal pumped by a frequency-doubled diode laser. A total output of 5.1 mW was obtained in the classical-nonclassical light-conversion system driven by a 50-mW diode laser at 1080 nm. A quantum-noise reduction of 4.3 dB (63%) in the intensity difference between the twin beams was successfully observed at the detection frequency of 3 MHz.

arXiv:quant-ph/0406113•Optics Letters•Jul 15, 2004•28 citations

Nonclassical light generation from an optical parametric oscillator pumped by a frequency-doubled diode laser

Kazuhiro Hayasaka, Yun Zhang, Katsuyuki Kasai

Quantum-correlated twin beams were successfully generated from an optical parametric oscillator (OPO) pumped by a frequency-doubled diode laser. The 50-mW diode laser output at 1080 nm was first converted to 22.5-mW green light, and then was used to pump an OPO to yield signal and idler beams with a total power of 5 mW. Noise reduction of 4.3 dB below the shot-noise level was observed in the intensity-difference spectrum. The setup opens a simple way to a compact and low-cost source of diverse nonclassical states of light.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 11, 2005•0 citations

Generation and application of twin beams from an optical parametric oscillator including an ?-cut KTP crystal

Jiangrui Gao, Fuyun Cui, Chenyang Xue +2 more

Measurement slight amounts of absorption of light with accuracy beyond the standard quantum limit has been experimentally demonstrated. The quantum-correlated twin beams used in the measurement were generated from a nondegenerate optical parametric oscillator including an alpha-cut KTiOPO(4) crystal pumped by an intracavity frequency-doubled Nd:YAG laser. The noise in the intensity difference between the twin beams was reduced by 88% below the standard quantum limit (SQL). The signal-to-noise ratio was improved by 7 dB with respect to the SQL of the total light employed in the experiment and by 4 dB with respect to that of the signal light.

Optics Letters•Jun 1, 1998•85 citations

Single-beam noise characteristics of quantum correlated twin beams

Yun Zhangx, Katsuyuki Kasai, Kazuhiro Hayasaka

We investigated the intensity noise spectra of the single beam of a pump-enhanced continuous-wave (cw) optical parametric oscillator (OPO), which was used to generate quantum correlated twin beams, as a function of the pump power. With a triply (pump-, signal-, and idler-) resonant cavity, the oscillation threshold of our OPO was about 8.5+/-1.3 mW and the measured slope conversion efficiency was 0.72+/-0.02. A twin beams with power of 240 mW were generated at pump power of 350 mW. The relaxation oscillation frequencies, which depend on the pump power, were observed when the pump power of OPO was from 12.5 mW to 28 mW. The experimental results confirm the predicted increase in OPO relaxation frequency with pump power. Squeezing of the single beam intensity was for the first time inferred experimentally by exploiting nature of quantum noise dependent on loss.

arXiv:quant-ph/0402119•Feb 18, 2004•0 citations
A laser-diode-pumped intracavity frequency-doubled Nd:YAP/KTP laser is presented. Over 110 mw of TEM00 single-frequency output power at 540-nm wavelength was obtained. The output green laser was employed to pump a semimonolithic nondegenerate optical parametric oscillator to produce intensity quantum correlated twin beams at 1080 nm, and the maximum quantum noise squeezing of 74% (5.9dB) on the intensity difference fluctuation between the twin beams is observed. The threshold was reduced and the stability was increased significantly when compared with similar lamp-pumped systems.
A strong quantum correlation between twin-beams at wavelength was observed. The intensity difference noise of twin-beams, which is generated by a semimonolithic OPO cavity pumped by a frequency-doubled and stabilized Nd:YAP laser, is about 80% (7 dB) below the short noise limit at the measurement frequency of 1.5 MHz. The threshold of the optical parametric oscillator is about 20 mW. The parametric dependence of the quantum correlation is experimentally investigated. The experimental results agree with the theory well.
Quantum-correlated twin beams were successfully generated from an optical parametric oscillator (OPO) pumped by a frequency-doubled diode laser. The 50-mW diode laser output at 1080 nm was first converted to 22.5-mW green light, and then was used to pump an OPO to yield signal and idler beams with a total power of 5 mW. Noise reduction of 4.3 dB below the shot-noise level was observed in the intensity-difference spectrum. The setup opens a simple way to a compact and low-cost source of diverse nonclassical states of light.
Measurement slight amounts of absorption of light with accuracy beyond the standard quantum limit has been experimentally demonstrated. The quantum-correlated twin beams used in the measurement were generated from a nondegenerate optical parametric oscillator including an alpha-cut KTiOPO(4) crystal pumped by an intracavity frequency-doubled Nd:YAG laser. The noise in the intensity difference between the twin beams was reduced by 88% below the standard quantum limit (SQL). The signal-to-noise ratio was improved by 7 dB with respect to the SQL of the total light employed in the experiment and by 4 dB with respect to that of the signal light.
We investigated the intensity noise spectra of the single beam of a pump-enhanced continuous-wave (cw) optical parametric oscillator (OPO), which was used to generate quantum correlated twin beams, as a function of the pump power. With a triply (pump-, signal-, and idler-) resonant cavity, the oscillation threshold of our OPO was about 8.5+/-1.3 mW and the measured slope conversion efficiency was 0.72+/-0.02. A twin beams with power of 240 mW were generated at pump power of 350 mW. The relaxation oscillation frequencies, which depend on the pump power, were observed when the pump power of OPO was from 12.5 mW to 28 mW. The experimental results confirm the predicted increase in OPO relaxation frequency with pump power. Squeezing of the single beam intensity was for the first time inferred experimentally by exploiting nature of quantum noise dependent on loss.