arXiv:quant-ph/0505198

Realisation of a Frequency Standard Using an Atomic Fountain

A. Michaud, Chowdhury, M., K. P. Zetie, C. J. Cooper, G. Hillenbrand, V. Lorent, Andrew M. Steane, Christopher J. Foot

Published May 26, 2005• 1 citation
arXivHTMLPDF

Abstract

We report the realisation and preliminary study of a frequency standard using a fountain of laser cooled caesium atoms. Our apparatus uses a magneto-optical trap as a source of cold atoms and optical pumping to prepare the atoms in the correct state before they enter the microwave cavity.
DOI
10.48550/arxiv.quant-ph/0505198

Related papers

A Laser-cooled Cesium Fountain Frequency Standard and a Measurement of the Frequency Shift due to Ultra-cold Collisions

Kurt Gibble, Steven Kasapi, Steven Chu

In our Cs atomic fountain, we laser cooled and trapped 10(exp 10) Cs atoms in 0.4 s. By shifting the frequencies of the laser beams, the atoms were launched upwards at 2.5 m/s and a fraction of the atoms were optically pumped into the F=3 ground state. The unwanted atoms in the F=4 ground state were removed from the fountain with radiation pressure from a laser beam tuned to excite only those atoms. The Cs atoms in the F=3 state traveled ballistically upwards, were excited by the microwave cavity, and then returned back through the same cavity in the atomic fountain configuration.

•Jun 1, 1993•0 citations

Work towards an atomic fountain clock at Peking University

Yimin Li, Jidong Hou, Junxian Fu +3 more

Cesium atomic fountain clock is the quantum frequency standard with very high accuracy. Research on laser cooling and trapping of cesium atom at Peking University began in 1993. A cesium atomic fountain frequency standard is being developed. A magneto-optical trap with some 108 trapped atoms and an optical molasses with the cold atoms of the temperature of 10/spl mu/K have been achieved previously. The device has been carefully designed and is under construction. It is composed of two main parts: vacuum system and laser system. The article describes the apparatus and presents a brief introduction to some considerations on the atomic clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•0 citations

Ultracold atoms and precise time standards

Gretchen K. Campbell, William D. Phillips

Experimental techniques of laser cooling and trapping, along with other cooling techniques, have produced gaseous samples of atoms so cold that they are, for many practical purposes, in the quantum ground state of their centre-of-mass motion. Such low velocities have virtually eliminated effects such as Doppler shifts, relativistic time dilation and observation-time broadening that previously limited the performance of atomic frequency standards. Today, the best laser-cooled, caesium atomic fountain, microwave frequency standards realize the International System of Units (SI) definition of the second to a relative accuracy of ≈3×10(-16). Optical frequency standards, which do not realize the SI second, have even better performance: cold neutral atoms trapped in optical lattices now yield relative systematic uncertainties of ≈1×10(-16), whereas cold-trapped ions have systematic uncertainties of 9×10(-18). We will discuss the current limitations in the performance of neutral atom atomic frequency standards and prospects for the future.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Sep 19, 2011•29 citations

Laser-cooled cesium atomic fountain experiment for atomic frequency standard

Jun Umezu, Yasusada Ohta, K. Hukuda +2 more

A cesium frequency standard based on the atomic fountain configuration has the potential of improving the accuracy of primary frequency standard. For the first step toward a realization of slow vertical atomic beam (that is an atomic fountain), we have succeeded to decelerate the horizontal cesium atomic beam by laser cooling with the Zeeman tuning method. Then those slowed atoms are confined with a magneto-optical trap by four laser beams in the tetrahedral configuration. By using these trapped atoms, one can launch them upward with the upstream laser pulses.>

Conference proceedings - IEEE Instrumentation/Measurement Technology Conference•Dec 17, 2002•0 citations

Article

Marie-Claude Gagné, J.-S. Boulanger, R J W Douglas

The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P

Canadian Journal of Physics•Aug 1, 1998•0 citations

A frequency standard based on a continuous beam of laser cooled atoms

P. Berthoud, Alain Joyet, P. Thomann +1 more

A frequency standard based on a continuous beam of laser cooled atoms as an alternative to a pulsed scheme of an atomic fountain is currently investigated. A general overview of such a device and its main parts are presented. Two mechanisms of continuous extraction of atoms from an anisotropic magneto-optical trap are experimentally demonstrated. Stability and accuracy issues are discussed.

Conference on Precision Electromagnetic Measurements•Nov 27, 2002•0 citations
In our Cs atomic fountain, we laser cooled and trapped 10(exp 10) Cs atoms in 0.4 s. By shifting the frequencies of the laser beams, the atoms were launched upwards at 2.5 m/s and a fraction of the atoms were optically pumped into the F=3 ground state. The unwanted atoms in the F=4 ground state were removed from the fountain with radiation pressure from a laser beam tuned to excite only those atoms. The Cs atoms in the F=3 state traveled ballistically upwards, were excited by the microwave cavity, and then returned back through the same cavity in the atomic fountain configuration.
Cesium atomic fountain clock is the quantum frequency standard with very high accuracy. Research on laser cooling and trapping of cesium atom at Peking University began in 1993. A cesium atomic fountain frequency standard is being developed. A magneto-optical trap with some 108 trapped atoms and an optical molasses with the cold atoms of the temperature of 10/spl mu/K have been achieved previously. The device has been carefully designed and is under construction. It is composed of two main parts: vacuum system and laser system. The article describes the apparatus and presents a brief introduction to some considerations on the atomic clock.
Experimental techniques of laser cooling and trapping, along with other cooling techniques, have produced gaseous samples of atoms so cold that they are, for many practical purposes, in the quantum ground state of their centre-of-mass motion. Such low velocities have virtually eliminated effects such as Doppler shifts, relativistic time dilation and observation-time broadening that previously limited the performance of atomic frequency standards. Today, the best laser-cooled, caesium atomic fountain, microwave frequency standards realize the International System of Units (SI) definition of the second to a relative accuracy of ≈3×10(-16). Optical frequency standards, which do not realize the SI second, have even better performance: cold neutral atoms trapped in optical lattices now yield relative systematic uncertainties of ≈1×10(-16), whereas cold-trapped ions have systematic uncertainties of 9×10(-18). We will discuss the current limitations in the performance of neutral atom atomic frequency standards and prospects for the future.
A cesium frequency standard based on the atomic fountain configuration has the potential of improving the accuracy of primary frequency standard. For the first step toward a realization of slow vertical atomic beam (that is an atomic fountain), we have succeeded to decelerate the horizontal cesium atomic beam by laser cooling with the Zeeman tuning method. Then those slowed atoms are confined with a magneto-optical trap by four laser beams in the tetrahedral configuration. By using these trapped atoms, one can launch them upward with the upstream laser pulses.>
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P