Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0405137 · Physical Review Letters

Squeezing in the Audio Gravitational-Wave Detection Band

Kirk McKenzie, Nicolai B. Grosse, Warwick P. Bowen, Stanley E. Whitcomb, Malcolm B. Gray, David E. McClelland, Ping Koy Lam

Published Oct 15, 2004• 215 citations
arXivHTMLPDF

Abstract

We demonstrate the generation of broadband continuous-wave optical squeezing from 280 Hz-100 kHz using a below-threshold optical parametric oscillator (OPO). The squeezed state phase was controlled using a noise locking technique. We show that low frequency noise sources, such as seed noise, pump noise, and detuning fluctuations, present in optical parametric amplifiers, have negligible effect on squeezing produced by a below-threshold OPO. This low frequency squeezing is ideal for improving the sensitivity of audio frequency measuring devices such as gravitational-wave detectors.

DOI
10.1103/physrevlett.93.161105

Related papers

Generation of low-frequency squeezed states

Liu Zeng-Jun, Zhai Ze-Hui, Sun Heng-Xin +1 more

Squeezed state of light is an important resource of optical measuerments below the shot noise limit and has been used to improve measurement sensitivity in many areas such as gravitational wave detection, especially in audio frequency region. Compared with the high-frequency squeezed states, the generation of the low-frequency squeezed states is more difficult, because it is limited by several technical noise sources. In this paper we report the observation of more than 2 dB of vacuum squeezing at 1064 nm in the gravitational-wave detection band down to 3 kHz with a double-resonant optical parametric oscillator (OPO). The OPO has a configuration of linear cavity consisting of an input coupling mirror with a transmission of 11% at 532 nm and an output coupling mirror with the transmission of 12% at 1064 nm. The nonlinear materials in the OPO is type-I periodically poled potassium titanyl phosphate (PPKTP) crystal which is chosen for this experiment due to its higher nonlinearity, broader phase matching temperature, and smaller photo-thermal effect. The OPO is pumped by the light of 532 nm from Nd: YVO4/KTP solid-state laser of maximum optical power 3 W. To avoid various noise coupled from the seed beam, the OPO is seeded by vacuum fluctuations instead of coherent field at the fundamental wavelength (1064 nm). A Pound-Drever-Hall (PDH) locking scheme is used to lock the OPO cavity length with the signal derived from the reflected pump beam, so as to lock the pump field and also lock the fundamental field. To make both the pump and seed beams resonant simultaneously, the temperature of the PPKTP is carefully adjusted. The squeezed state can be detected on a homodyne detection by interfering it with the local oscillator (LO) and detected by a balanced detector with two photodiodes (EXT500 T) but having the same quantum efficiency of 86% at 1064 nm. The subsequent electronic noise is analyzed with a low-frequency spectrum analyzer, which shows that the audio noise sources from lab enviroment, locking quality, escape efficiency, propagation loss, homodyne efficiency and detection efficiency have effect on the squeezing pruced by an OPO.

Acta Physica Sinica•Jan 1, 2016•2 citations

Squeezed state generation for interferometric gravitational-wave detection

Kirk McKenzie, Malcolm B. Gray, S. Goßler +2 more

In this paper we present results demonstrating the development of a squeezed state at sideband frequencies as low as 100 Hz. The squeezed source was generated in a doubly resonant optical parametric oscillator (OPO) operated below threshold. The OPO resonance condition is achieved using the pump field, allowing the OPO to produce a squeezed vacuum state stably. We describe limitations to the experiment and discuss future work.

Classical and Quantum Gravity•Mar 29, 2006•22 citations

Coherent Control of Vacuum Squeezing in the Gravitational-Wave Detection Band

H. Vahlbruch, S. Chelkowski, Boris Hage +3 more

We propose and demonstrate a coherent control scheme for stable phase locking of squeezed vacuum fields. We focus on sideband fields at frequencies from 10 Hz to 10 kHz, which is a frequency regime of particular interest in gravitational-wave detection and for which conventional control schemes have failed so far. A vacuum field with broadband squeezing covering this entire band was produced using optical parametric oscillation and characterized with balanced homodyne detection. The system was stably controlled over long periods utilizing two coherent but frequency shifted control fields. In order to demonstrate the performance of our setup the squeezed field was used for a nonclassical sensitivity improvement of a Michelson interferometer at audio frequencies.

arXiv:0707.0164•Physical Review Letters•Jul 6, 2006•225 citations

Generation of squeezed states at low analysis frequencies

Xin Wen, Yashuai Han, Liu Jin-Yu +3 more

Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.

Acta Physica Sinica•Jan 1, 2018•4 citations

Generation of audio-band frequency squeezed light at 1.34 μm

Feng Jin-Xia, 杜京师 DU Jing-shi, Jin Xiao-Li +2 more

Continuous variable (CV) audio-band frequency squeezed states at the fiber telecommunication wavelength is an important quantum resource for the practical applications based on optical fiber. As is well known, the optical power attenuation and phase diffusion effect of light at 1.3 μm in standard telecommunication fibres are low and small, respectively. The audio-band frequency squeezed light at 1.34 μm can be utilized to realize quantum precision measurement, such as quantum-enhanced sensing in the low-frequency range, laser interferometer for gravitational wave detection. In this paper, CV audio-band frequency vacuum squeezed states at 1.3 μm are experimentally generated by using a type-I degenerate optical parametric oscillator (DOPO) below the threshold. A home-made continuous-wave single-frequency dual-wavelength (671 nm and 1.34 μm) Nd:YVO4/LBO laser is used as a pump source for DOPO based on a type-I quasi-phase-matched periodically poled KTiOPO4 (PPKTP) crystal. Mode cleaners with a finesse of 400 and linewidth of 0.75 MHz are used to filter the noise of lasers at 671 nm and 1.34 μm, respectively. The intensity noises of the two lasers reach a shot noise level for analysis frequencies higher than 1.0 MHz and their phase noises reach shot noise level for analysis frequencies higher than 1.3 MHz, respectively. The low noise single-frequency 671 nm laser is utilized as a pump of the DOPO. The threshold power of the DOPO is 450 mW. In order to detect the audio-band frequency vacuum squeezed states, the power of local oscillator of a homodyne detector system is optimized to 60 μupW. Furthermore, the effect of common mode rejection ratio (CMRR) of detectors is discussed in detecting the audio-band frequency vacuum squeezed states. Improvement of CMRR of detectors is a good way to detect the audio-band frequency vacuum squeezed states effectively. When the phase matching temperature of PPKTP crystal is controlled at 53℃ by using a home-made temperature controller and the pump power is 95 mW, the vacuum squeezed states are generated at analysis frequency ranging from 8-100 kHz. A maximum measured squeeze of 5.0 dB is obtained at analysis frequency of 36 kHz. A 3.0 dB squeezed light is obtained at an audio-band frequency of 8 kHz.

Acta Physica Sinica•Jan 1, 2018•2 citations

Audio-Band Frequency-Dependent Squeezing for Gravitational-Wave Detectors

Eric Glenn Oelker, Tomoki Isogai, John Miller +4 more

Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. However, optomechanical interactions dictate that the vacuum's squeezed quadrature must rotate by 90° around 50 Hz. Here we use a 2-m-long, high-finesse optical resonator to produce frequency-dependent rotation around 1.2 kHz. This demonstration of audio-band frequency-dependent squeezing uses technology and methods that are scalable to the required rotation frequency and validates previously developed theoretical models, heralding application of the technique in future gravitational-wave detectors.

arXiv:1508.04700•Physical Review Letters•Jan 29, 2016•94 citations
We demonstrate the generation of broadband continuous-wave optical squeezing from 280 Hz-100 kHz using a below-threshold optical parametric oscillator (OPO). The squeezed state phase was controlled using a noise locking technique. We show that low frequency noise sources, such as seed noise, pump noise, and detuning fluctuations, present in optical parametric amplifiers, have negligible effect on squeezing produced by a below-threshold OPO. This low frequency squeezing is ideal for improving the sensitivity of audio frequency measuring devices such as gravitational-wave detectors.
Squeezed state of light is an important resource of optical measuerments below the shot noise limit and has been used to improve measurement sensitivity in many areas such as gravitational wave detection, especially in audio frequency region. Compared with the high-frequency squeezed states, the generation of the low-frequency squeezed states is more difficult, because it is limited by several technical noise sources. In this paper we report the observation of more than 2 dB of vacuum squeezing at 1064 nm in the gravitational-wave detection band down to 3 kHz with a double-resonant optical parametric oscillator (OPO). The OPO has a configuration of linear cavity consisting of an input coupling mirror with a transmission of 11% at 532 nm and an output coupling mirror with the transmission of 12% at 1064 nm. The nonlinear materials in the OPO is type-I periodically poled potassium titanyl phosphate (PPKTP) crystal which is chosen for this experiment due to its higher nonlinearity, broader phase matching temperature, and smaller photo-thermal effect. The OPO is pumped by the light of 532 nm from Nd: YVO4/KTP solid-state laser of maximum optical power 3 W. To avoid various noise coupled from the seed beam, the OPO is seeded by vacuum fluctuations instead of coherent field at the fundamental wavelength (1064 nm). A Pound-Drever-Hall (PDH) locking scheme is used to lock the OPO cavity length with the signal derived from the reflected pump beam, so as to lock the pump field and also lock the fundamental field. To make both the pump and seed beams resonant simultaneously, the temperature of the PPKTP is carefully adjusted. The squeezed state can be detected on a homodyne detection by interfering it with the local oscillator (LO) and detected by a balanced detector with two photodiodes (EXT500 T) but having the same quantum efficiency of 86% at 1064 nm. The subsequent electronic noise is analyzed with a low-frequency spectrum analyzer, which shows that the audio noise sources from lab enviroment, locking quality, escape efficiency, propagation loss, homodyne efficiency and detection efficiency have effect on the squeezing pruced by an OPO.
We propose and demonstrate a coherent control scheme for stable phase locking of squeezed vacuum fields. We focus on sideband fields at frequencies from 10 Hz to 10 kHz, which is a frequency regime of particular interest in gravitational-wave detection and for which conventional control schemes have failed so far. A vacuum field with broadband squeezing covering this entire band was produced using optical parametric oscillation and characterized with balanced homodyne detection. The system was stably controlled over long periods utilizing two coherent but frequency shifted control fields. In order to demonstrate the performance of our setup the squeezed field was used for a nonclassical sensitivity improvement of a Michelson interferometer at audio frequencies.
Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.
Continuous variable (CV) audio-band frequency squeezed states at the fiber telecommunication wavelength is an important quantum resource for the practical applications based on optical fiber. As is well known, the optical power attenuation and phase diffusion effect of light at 1.3 μm in standard telecommunication fibres are low and small, respectively. The audio-band frequency squeezed light at 1.34 μm can be utilized to realize quantum precision measurement, such as quantum-enhanced sensing in the low-frequency range, laser interferometer for gravitational wave detection. In this paper, CV audio-band frequency vacuum squeezed states at 1.3 μm are experimentally generated by using a type-I degenerate optical parametric oscillator (DOPO) below the threshold. A home-made continuous-wave single-frequency dual-wavelength (671 nm and 1.34 μm) Nd:YVO4/LBO laser is used as a pump source for DOPO based on a type-I quasi-phase-matched periodically poled KTiOPO4 (PPKTP) crystal. Mode cleaners with a finesse of 400 and linewidth of 0.75 MHz are used to filter the noise of lasers at 671 nm and 1.34 μm, respectively. The intensity noises of the two lasers reach a shot noise level for analysis frequencies higher than 1.0 MHz and their phase noises reach shot noise level for analysis frequencies higher than 1.3 MHz, respectively. The low noise single-frequency 671 nm laser is utilized as a pump of the DOPO. The threshold power of the DOPO is 450 mW. In order to detect the audio-band frequency vacuum squeezed states, the power of local oscillator of a homodyne detector system is optimized to 60 μupW. Furthermore, the effect of common mode rejection ratio (CMRR) of detectors is discussed in detecting the audio-band frequency vacuum squeezed states. Improvement of CMRR of detectors is a good way to detect the audio-band frequency vacuum squeezed states effectively. When the phase matching temperature of PPKTP crystal is controlled at 53℃ by using a home-made temperature controller and the pump power is 95 mW, the vacuum squeezed states are generated at analysis frequency ranging from 8-100 kHz. A maximum measured squeeze of 5.0 dB is obtained at analysis frequency of 36 kHz. A 3.0 dB squeezed light is obtained at an audio-band frequency of 8 kHz.
Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. However, optomechanical interactions dictate that the vacuum's squeezed quadrature must rotate by 90° around 50 Hz. Here we use a 2-m-long, high-finesse optical resonator to produce frequency-dependent rotation around 1.2 kHz. This demonstration of audio-band frequency-dependent squeezing uses technology and methods that are scalable to the required rotation frequency and validates previously developed theoretical models, heralding application of the technique in future gravitational-wave detectors.