Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0707.0164 · Physical Review Letters

Coherent Control of Vacuum Squeezing in the Gravitational-Wave Detection Band

H. Vahlbruch, S. Chelkowski, Boris Hage, Alexander Franzen, K. Danzmann, Roman Schnabel

Published Jul 6, 2006• 225 citations
arXivHTMLPDF

Abstract

We propose and demonstrate a coherent control scheme for stable phase locking of squeezed vacuum fields. We focus on sideband fields at frequencies from 10 Hz to 10 kHz, which is a frequency regime of particular interest in gravitational-wave detection and for which conventional control schemes have failed so far. A vacuum field with broadband squeezing covering this entire band was produced using optical parametric oscillation and characterized with balanced homodyne detection. The system was stably controlled over long periods utilizing two coherent but frequency shifted control fields. In order to demonstrate the performance of our setup the squeezed field was used for a nonclassical sensitivity improvement of a Michelson interferometer at audio frequencies.

DOI
10.1103/physrevlett.97.011101

Related papers

Coherent control of broadband vacuum squeezing

S. Chelkowski, H. Vahlbruch, K. Danzmann +1 more

We present the observation of optical fields carrying squeezed vacuum states at sideband frequencies from $10\phantom{\rule{0.3em}{0ex}}\mathrm{Hz}$ to above $35\phantom{\rule{0.3em}{0ex}}\mathrm{MHz}$. The field was generated with type-I optical parametric oscillation below threshold at $1064\phantom{\rule{0.3em}{0ex}}\mathrm{nm}$. A coherent, unbalanced classical modulation field at $40\phantom{\rule{0.3em}{0ex}}\mathrm{MHz}$ enabled the generation of error signals for stable phase control of the squeezed vacuum field with respect to a strong local oscillator. Broadband squeezing of approximately $\ensuremath{-}4\phantom{\rule{0.3em}{0ex}}\mathrm{dB}$ was measured with balanced homodyne detection. The spectrum of the squeezed field allows a quantum noise reduction of ground-based gravitational wave detectors over their full detection band, regardless of whether homodyne readout or radio-frequency heterodyne readout is used.

arXiv:0704.3796•Physical Review A•Apr 23, 2007•71 citations

Squeezed light for gravitational wave astronomy

H. Vahlbruch

During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.

•Jan 1, 2008•12 citations

Squeezing in the Audio Gravitational-Wave Detection Band

Kirk McKenzie, Nicolai B. Grosse, Warwick P. Bowen +4 more

We demonstrate the generation of broadband continuous-wave optical squeezing from 280 Hz-100 kHz using a below-threshold optical parametric oscillator (OPO). The squeezed state phase was controlled using a noise locking technique. We show that low frequency noise sources, such as seed noise, pump noise, and detuning fluctuations, present in optical parametric amplifiers, have negligible effect on squeezing produced by a below-threshold OPO. This low frequency squeezing is ideal for improving the sensitivity of audio frequency measuring devices such as gravitational-wave detectors.

arXiv:quant-ph/0405137•Physical Review Letters•Oct 15, 2004•215 citations

Long-term stable squeezed vacuum state of light for gravitational wave detectors

A. Khalaidovski, H. Vahlbruch, N. Lastzka +4 more

Currently, the German/British gravitational wave detector GEO600 is being upgraded in course of the GEO-HF program. One part of this upgrade consists of the integration of a squeezed light laser to nonclassically improve the detection sensitivity at frequencies where the instrument is limited by shot noise. This has been achieved recently [1]. The permanent employment of squeezed light in gravitational wave observatories requires a long-term stability of the generated squeezed state. In this paper, we discuss an unwanted mechanism that can lead to a varying squeezing factor along with a changing phase of the squeezed field. We present an extension of the implemented coherent control scheme [2] that allowed an increase in the long-term stability of the GEO600 squeezed light laser. With it, a quantum noise reduction by more than 9 dB in the frequency band of 10 Hz - 10 kHz was observed over up to 20 hours with a duty cycle of more than 99%.

arXiv:1109.3731•Classical and Quantum Gravity•Mar 6, 2012•46 citations

Advanced techniques for squeezed-light-enhanced gravitational-wave detection

J. Gniesmer

Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.

•Jan 1, 2019•0 citations

Balanced homodyne detection of optical quantum states at audio-band frequencies and below

M S Stefszky, C M Mow-Lowry, S. Chua +7 more

The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.

arXiv:1205.3229•Classical and Quantum Gravity•Jun 25, 2012•127 citations
We propose and demonstrate a coherent control scheme for stable phase locking of squeezed vacuum fields. We focus on sideband fields at frequencies from 10 Hz to 10 kHz, which is a frequency regime of particular interest in gravitational-wave detection and for which conventional control schemes have failed so far. A vacuum field with broadband squeezing covering this entire band was produced using optical parametric oscillation and characterized with balanced homodyne detection. The system was stably controlled over long periods utilizing two coherent but frequency shifted control fields. In order to demonstrate the performance of our setup the squeezed field was used for a nonclassical sensitivity improvement of a Michelson interferometer at audio frequencies.
We present the observation of optical fields carrying squeezed vacuum states at sideband frequencies from 10Hz10\phantom{\rule{0.3em}{0ex}}\mathrm{Hz}10Hz to above 35MHz35\phantom{\rule{0.3em}{0ex}}\mathrm{MHz}35MHz. The field was generated with type-I optical parametric oscillation below threshold at 1064nm1064\phantom{\rule{0.3em}{0ex}}\mathrm{nm}1064nm. A coherent, unbalanced classical modulation field at 40MHz40\phantom{\rule{0.3em}{0ex}}\mathrm{MHz}40MHz enabled the generation of error signals for stable phase control of the squeezed vacuum field with respect to a strong local oscillator. Broadband squeezing of approximately $\ensuremath{-}4\phantom{\rule{0.3em}{0ex}}\mathrm{dB}$ was measured with balanced homodyne detection. The spectrum of the squeezed field allows a quantum noise reduction of ground-based gravitational wave detectors over their full detection band, regardless of whether homodyne readout or radio-frequency heterodyne readout is used.
During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.
We demonstrate the generation of broadband continuous-wave optical squeezing from 280 Hz-100 kHz using a below-threshold optical parametric oscillator (OPO). The squeezed state phase was controlled using a noise locking technique. We show that low frequency noise sources, such as seed noise, pump noise, and detuning fluctuations, present in optical parametric amplifiers, have negligible effect on squeezing produced by a below-threshold OPO. This low frequency squeezing is ideal for improving the sensitivity of audio frequency measuring devices such as gravitational-wave detectors.
Currently, the German/British gravitational wave detector GEO600 is being upgraded in course of the GEO-HF program. One part of this upgrade consists of the integration of a squeezed light laser to nonclassically improve the detection sensitivity at frequencies where the instrument is limited by shot noise. This has been achieved recently [1]. The permanent employment of squeezed light in gravitational wave observatories requires a long-term stability of the generated squeezed state. In this paper, we discuss an unwanted mechanism that can lead to a varying squeezing factor along with a changing phase of the squeezed field. We present an extension of the implemented coherent control scheme [2] that allowed an increase in the long-term stability of the GEO600 squeezed light laser. With it, a quantum noise reduction by more than 9 dB in the frequency band of 10 Hz - 10 kHz was observed over up to 20 hours with a duty cycle of more than 99%.
Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.
The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.