Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0102116 · Physical Review A

Minimal absorption measurements

Serge Massar, Graeme Mitchison, Stefano Pironio

Published Nov 9, 2001• 12 citations
arXivHTMLPDF

Abstract

In this paper, we consider the problem of trying to make an image of an object while minimizing the number of photons absorbed by the object. We call protocols that achieve this goal ``minimal absorption measurements.'' Such imaging techniques are particularly relevant in situations where the object may be damaged by the radiation used to make the image. Our main result is a bound that relates the minimum number of absorbed photons to the sensitivity of the measurement. This bound holds where $\ensuremath{\epsilon},$ half the difference between the transparencies, is sufficently small. In the case where the object consists of a single pixel, we show that the dependency of our bound on $\ensuremath{\epsilon}$ may be reproduced by simply counting the number of photons absorbed by the object or by a simple interferometric setup, depending on the details of the problem. In the case where the object consists of many pixels, we give an example where our bound may be approached when all the pixels are addressed collectively, whereas addressing each pixel individually implies an increase in the number of absorbed photons by a factor logarithmic in the number of pixels. Finally, we consider some special situations where our bound does not apply, and where interferometric methods may make large gains.

DOI
10.1103/physreva.64.062303

Related papers

Quantum Enhanced Optical Measurements: From Ultra-High Sensitivity in Absorption Measurements to Ghost Microscopy

Elena Losero, Ivano Ruo Berchera, Alessio Avella +2 more

Quantum enhanced optical measurement protocols aim at reducing the uncertainty in the estimation of some physical quantities of a system below the shot-noise limit, classically unavoidable. In particular when small number of photons is used the shot noise can be the main source of uncertainty, in these cases the use of quantum light is of great interest. Note that there are several situations where the number of photons in the probe can not be increased arbitrarily, as when fragile biological samples are under investigation. Two different imaging protocols are discussed in the following.

Italian Quantum Information Science Conference (IQIS)•Jul 25, 2019•0 citations

Quantum Interrogation and the Safer X-ray

Adrian Kent, David Wallace

We investigate quantum interrogation techniques which allow imaging information about semi-transparent objects to be obtained with lower absorption rates than standard classical methods. We show that a gain proportional to log N can be obtained when searching for defects in an array of N pixels, if it is known that at most M of the pixels can have transparencies different from a predetermined theoretical value. A logarithmic gain can also be obtained when searching for infrequently occurring large structures in arrays.

arXiv:quant-ph/0102118•Feb 22, 2001•7 citations

A universal loss-limited optimum for fixed multi-pass quantum sensing per absorbed photon

Christoph F. Wildfeuer

Multi-pass schemes send a photon through a sample several times to learn more about it. When the sample rather than the light is scarce, the natural figure of merit is the information gained per photon the object absorbs. We show that one constant fixes the loss-limited optimum of every fixed scheme in which a single photon passes repeatedly through the sample and is detected once at the end. Three properties suffice: information that grows as the square of the pass number, a fixed survival probability per pass, and no dose from a photon already lost. They force a single trade-off function $h(x)=x^2/(e^x-1)$, where $x$ is the number of passes times the loss per pass. Its maximum, 0.648, sits at $x_{\mathrm{opt}}=1.594$. The loss-limited ceiling of interaction-free interrogation and the multi-pass phase optimum of Yu et al. are two instances. Phase sensing of a weakly absorbing object is a third, optimal at $m_{\mathrm{opt}}=x_{\mathrm{opt}}/(ε+α)$ passes; the absorption $α$ and the parasitic loss $ε$ enter the optimum only through their sum, but the damage counts only $α$. N00N states and their loss-robust generalisations do worse per absorbed photon, and optimising over photon number and pass number together returns a single recycled photon. Two further problems are priced in the same measure. Absorption estimation gains nothing, for any scheme. Detecting a faint companion below the Rayleigh limit costs the companion a dose that does not depend on its faintness, while under direct imaging the dose grows without bound. For a fragile sample the gentlest measurement is also the simplest one: a single photon, recycled.

quant-pharXiv:2608.25534•Mathematics•Aug 27, 2026•1 citation

Counterfactual Ghost Imaging

Jonte R. Hance, Rarity J

We give a protocol for ghost imaging in a way that is always counterfactual—while imaging an object, no light interacts with that object. This extends the idea of counterfactuality beyond communication, showing how this interesting phenomenon can be leveraged for metrology. Given, in the infinite limit, no photons ever go to the imaged object, it presents a method of imaging even the most light-sensitive of objects without damaging them. Even when not in the infinite limit, it still provides a many-fold improvement in visibility and signal-to-noise ratio over previous protocols, with over an order of magnitude reduction in absorbed intensity.

•Jun 2, 2021•0 citations

Quantum-optimized phase closure for robust interferometric imaging

Zhenning Liu, Emil T. Khabiboulline, Lorcan O. Conlon +7 more

Closure phase enables imaging with ground-based interferometric arrays by canceling telescope-dependent phase errors due to atmospheric fluctuations. It can be obtained by measuring fringe phases on individual baselines forming a triangle and summing them. We show that closure phases can be measured more accurately with fewer photons by performing joint measurements on multiple photons. We first establish that at least three photons from the same atmospheric temporal phase-stability window are required for closure-phase information to survive the unknown telescope-dependent phase noise, and show that joint three-photon measurements already provide an advantage over single-photon measurements in the minimal three-telescope setting. We then turn to large arrays and consider estimating all bispectra---complex quantities whose phases are the closure phases---under a global mean-square error criterion. Although an $m$-telescope array contains $Θ(m^2)$ independent triangle bispectra, we show that physical constraints on the visibilities make the total information content grow only nearly linearly with $m$ at fixed accuracy. Exploiting this structure, we construct an efficient protocol using at most three-photon joint measurements with photon cost $\tilde{O}(m)$, whereas any sequential single-photon protocol requires $Ω(m^2)$ photons. When the number of detected photons per temporal stability window scales linearly with the array size, this allows the required exposure time to remain independent of $m$ up to logarithmic factors. We further analyze the complementary high-precision regime using multiparameter quantum metrology and find a similar advantage for collective measurements. Overall, our results show that quantum information processing techniques can substantially improve the sensitivity and robustness of optical interferometry.

quant-pharXiv:2610.06786•Oct 6, 2026•1 citation

Counterfactual ghost imaging

Jonte R. Hance, John Rarity

Abstract We give a protocol for ghost imaging in a way that is always counterfactual—while imaging an object, no light interacts with that object. This extends the idea of counterfactuality beyond communication, showing how this interesting phenomenon can be leveraged for metrology. Given, in the infinite limit, no photons ever go to the imaged object, it presents a method of imaging even the most light-sensitive of objects without damaging them. Even when not in the infinite limit, it still provides a many-fold improvement in visibility and signal-to-noise ratio over previous protocols, with over an order of magnitude reduction in absorbed intensity.

arXiv:2010.14292•npj Quantum Information•Jun 2, 2021•39 citations
In this paper, we consider the problem of trying to make an image of an object while minimizing the number of photons absorbed by the object. We call protocols that achieve this goal ``minimal absorption measurements.'' Such imaging techniques are particularly relevant in situations where the object may be damaged by the radiation used to make the image. Our main result is a bound that relates the minimum number of absorbed photons to the sensitivity of the measurement. This bound holds where \ensuremathϵ,\ensuremath{\epsilon},\ensuremathϵ, half the difference between the transparencies, is sufficently small. In the case where the object consists of a single pixel, we show that the dependency of our bound on \ensuremathϵ\ensuremath{\epsilon}\ensuremathϵ may be reproduced by simply counting the number of photons absorbed by the object or by a simple interferometric setup, depending on the details of the problem. In the case where the object consists of many pixels, we give an example where our bound may be approached when all the pixels are addressed collectively, whereas addressing each pixel individually implies an increase in the number of absorbed photons by a factor logarithmic in the number of pixels. Finally, we consider some special situations where our bound does not apply, and where interferometric methods may make large gains.
Quantum enhanced optical measurement protocols aim at reducing the uncertainty in the estimation of some physical quantities of a system below the shot-noise limit, classically unavoidable. In particular when small number of photons is used the shot noise can be the main source of uncertainty, in these cases the use of quantum light is of great interest. Note that there are several situations where the number of photons in the probe can not be increased arbitrarily, as when fragile biological samples are under investigation. Two different imaging protocols are discussed in the following.
We investigate quantum interrogation techniques which allow imaging information about semi-transparent objects to be obtained with lower absorption rates than standard classical methods. We show that a gain proportional to log N can be obtained when searching for defects in an array of N pixels, if it is known that at most M of the pixels can have transparencies different from a predetermined theoretical value. A logarithmic gain can also be obtained when searching for infrequently occurring large structures in arrays.
Multi-pass schemes send a photon through a sample several times to learn more about it. When the sample rather than the light is scarce, the natural figure of merit is the information gained per photon the object absorbs. We show that one constant fixes the loss-limited optimum of every fixed scheme in which a single photon passes repeatedly through the sample and is detected once at the end. Three properties suffice: information that grows as the square of the pass number, a fixed survival probability per pass, and no dose from a photon already lost. They force a single trade-off function h(x)=x2/(ex−1)h(x)=x^2/(e^x-1)h(x)=x2/(ex−1), where xxx is the number of passes times the loss per pass. Its maximum, 0.648, sits at xopt=1.594x_{\mathrm{opt}}=1.594xopt​=1.594. The loss-limited ceiling of interaction-free interrogation and the multi-pass phase optimum of Yu et al. are two instances. Phase sensing of a weakly absorbing object is a third, optimal at mopt=xopt/(ε+α)m_{\mathrm{opt}}=x_{\mathrm{opt}}/(ε+α)mopt​=xopt​/(ε+α) passes; the absorption ααα and the parasitic loss εεε enter the optimum only through their sum, but the damage counts only ααα. N00N states and their loss-robust generalisations do worse per absorbed photon, and optimising over photon number and pass number together returns a single recycled photon. Two further problems are priced in the same measure. Absorption estimation gains nothing, for any scheme. Detecting a faint companion below the Rayleigh limit costs the companion a dose that does not depend on its faintness, while under direct imaging the dose grows without bound. For a fragile sample the gentlest measurement is also the simplest one: a single photon, recycled.
We give a protocol for ghost imaging in a way that is always counterfactual—while imaging an object, no light interacts with that object. This extends the idea of counterfactuality beyond communication, showing how this interesting phenomenon can be leveraged for metrology. Given, in the infinite limit, no photons ever go to the imaged object, it presents a method of imaging even the most light-sensitive of objects without damaging them. Even when not in the infinite limit, it still provides a many-fold improvement in visibility and signal-to-noise ratio over previous protocols, with over an order of magnitude reduction in absorbed intensity.
Closure phase enables imaging with ground-based interferometric arrays by canceling telescope-dependent phase errors due to atmospheric fluctuations. It can be obtained by measuring fringe phases on individual baselines forming a triangle and summing them. We show that closure phases can be measured more accurately with fewer photons by performing joint measurements on multiple photons. We first establish that at least three photons from the same atmospheric temporal phase-stability window are required for closure-phase information to survive the unknown telescope-dependent phase noise, and show that joint three-photon measurements already provide an advantage over single-photon measurements in the minimal three-telescope setting. We then turn to large arrays and consider estimating all bispectra---complex quantities whose phases are the closure phases---under a global mean-square error criterion. Although an mmm-telescope array contains Θ(m2)Θ(m^2)Θ(m2) independent triangle bispectra, we show that physical constraints on the visibilities make the total information content grow only nearly linearly with mmm at fixed accuracy. Exploiting this structure, we construct an efficient protocol using at most three-photon joint measurements with photon cost O~(m)\tilde{O}(m)O~(m), whereas any sequential single-photon protocol requires Ω(m2)Ω(m^2)Ω(m2) photons. When the number of detected photons per temporal stability window scales linearly with the array size, this allows the required exposure time to remain independent of mmm up to logarithmic factors. We further analyze the complementary high-precision regime using multiparameter quantum metrology and find a similar advantage for collective measurements. Overall, our results show that quantum information processing techniques can substantially improve the sensitivity and robustness of optical interferometry.
Abstract We give a protocol for ghost imaging in a way that is always counterfactual—while imaging an object, no light interacts with that object. This extends the idea of counterfactuality beyond communication, showing how this interesting phenomenon can be leveraged for metrology. Given, in the infinite limit, no photons ever go to the imaged object, it presents a method of imaging even the most light-sensitive of objects without damaging them. Even when not in the infinite limit, it still provides a many-fold improvement in visibility and signal-to-noise ratio over previous protocols, with over an order of magnitude reduction in absorbed intensity.