Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:physics/0611014 · Physical Review A

Synchronous optical pumping of quantum revival beats for atomic magnetometry

Scott J. Seltzer, Parker Meares, Michael V. Romalis

Published May 30, 2007• 72 citations
arXivHTMLPDF

Abstract

We observe quantum beats with periodic revivals due to nonlinear spacing of Zeeman levels in the ground state of potassium atoms, and demonstrate their synchronous optical pumping by double modulation of the pumping light at the Larmor frequency and the revival frequency. We show that synchronous pumping increases the degree of spin polarization by a factor of 4. As a practical example, we explore the application of this double-modulation technique to atomic magnetometers operating in the geomagnetic field range, and find that it can increase the sensitivity and reduce magnetic-field-orientation-dependent measurement errors endemic to alkali-metal magnetometers.

DOI
10.1103/physreva.75.051407

Related papers

Optical magnetometry with modulated light

Derek F. Jackson Kimball, Szymon Pustelny, Valeriy V. Yashchuk +1 more

Introduction Soon after the development of optical magnetometers based on the radio-optical double resonance method (see Chapter 4), it was realized by Bell and Bloom [1] that an alternative method for optical magnetometry was to modulate the light used for optical pumping at a frequency resonant with the Larmor precession of atomic spins. In a Bell-Bloom optical magnetometer, circularly polarized light resonant with an atomic transition propagates through an atomic vapor along a direction transverse to a magnetic field B . Atomic spins immersed in B precess at the Larmor frequency Ω L , and when the light intensity is modulated at Ω m = Ω L , a resonance in the transmitted light intensity is observed. The essential ideas of the Bell–Bloom optical magnetometer are reviewed in Chapter 1 (Section 1.2), and can be summarized in terms of what Bell and Bloom termed optically driven spin precession: in analogy with a driven harmonic oscillator, in a magnetic field B atomic spins precess at a natural frequency equal to Ω L and the light acts as a driving force oscillating at the modulation frequency Ω m . From another point of view, the Bell-Bloom optical magnetometer can be described in terms of synchronous optical pumping: when Ω m = Ω L , there is a “stroboscopic” resonance in which atoms are optically pumped into a spin state stationary in the frame rotating with Ω L . Depending on the details of the atomic structure, the spin state stationary in the rotating frame can be either a dark state that does not interact with the modulated light or a bright state for which the strength of the light–atom interaction is increased.

Cambridge University Press eBooks•Mar 7, 2013•6 citations

Remote detection magnetometry

Simon Rochester, James Higbie, Bob J. Patton +3 more

Introduction Shortly after the inception of atomic magnetometry, alkali-vapor magnetometers were being used to measure the Earth's magnetic field to unprecedented precision. During the same era, Bell and Bloom first demonstrated all-optical atomic magnetometry through synchronous optical pumping [1] (see Chapters 1 and 6). In this approach, optical-pumping light is frequency- or amplitude-modulated at harmonics of the Larmor frequency ω L to generate a precessing spin polarization within an alkali vapor at finite magnetic field [2, 3]. Although this technique received considerable attention from the atomic physics community for its applicability to optical pumping experiments, Earth's-field alkali-vapor atomic magnetometers continued to rely on radiofrequency (RF) field excitation for several decades (see Chapter 4). Upon the advent of diode lasers addressing alkali and metastable helium transitions, synchronously pumped magnetometers experienced a revival beginning in the late 1980s. In recent years, such magnetometers have found applications in nuclear magnetic resonance detection [4] (see also Chapter 14), quantum control experiments [5], and chip-scale devices intended for spacecraft use [6] (see also Chapters 7 and 15). All-optical magnetometers possess several advantages over devices that employ RF coils. RF-driven magnetometers can suffer from cross-talk if two sensors are placed in close proximity, since the AC magnetic field driving resonance in one vapor cell can adversely affect the other. All-optical magnetometers are free from such interference. When operated in self-oscillating mode [7], RF-driven magnetometers require an added ±90° electronic phase shift in the feedback loop to counter the intrinsic phase shift between the RF field and the probe-beam modulation.

Cambridge University Press eBooks•Mar 7, 2013•0 citations

Magneto-optic spectroscopy with linearly polarized modulated light: Theory and experiment

G. Bevilacqua, Evelina Breschi

We investigate the polarization modulation between two linear orthogonal states of the laser beam that synchronously pumps time-dependent atomic alignment in caesium atoms exposed to a static magnetic field. Because of the atomic alignment symmetry two independent groups of resonances can be distinguished in the transmitted light: when modulation frequency matches either the Larmor frequency or its second harmonics, ${\ensuremath{\omega}}_{L}$ and $2{\ensuremath{\omega}}_{L}$, respectively. We report on our experiments, and discuss a model that perfectly reproduces the observed spectra. We have observed that the amplitudes and linewidths of resonances at ${\ensuremath{\omega}}_{L}$ and $2{\ensuremath{\omega}}_{L}$ show magnetic-field direction dependence. This peculiar behavior makes our approach interesting for future application to atomic magnetometry, in view of a dead-zone free high-sensitivity magnetometer.

Physical Review A•Jun 18, 2014•15 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•6 citations

Simultaneous Observation of Nonlinear Magneto-Optical Rotation in the Temporal and Spectral Domains with an Electro-Optic Frequency Comb

Nathanial Wilson, Nicolas Bourbeau Hébert, Christopher Perrella +4 more

Highly sensitive magnetic field measurements are desirable for medical diagnoses and imaging, as well as research in geomagnetism and fundamental physics. Atomic magnetometers measure the Larmor frequency of an alkali vapor, and their sensitivity depends on generating a high degree of ground-state coherence in the atomic population via optical pumping. This study uses an electro-optic frequency comb to probe a broad spectral region, yielding measurements of the Larmor frequency that are both temporally and spectrally resolved. The techniques developed here allow real-time analysis of the degree of polarization of the atomic ensemble, and the avenues by which this polarization is probed.

Physical Review Applied•Sep 7, 2018•17 citations

Suppression of heading errors in Bell-Bloom optically pumped free-induction-decay alkali-metal atomic magnetometers

S.-Q. Liu, X.-K. Wang, Xiangdong Zhang +2 more

Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.

arXiv:2502.13414•Physical Review A•Feb 26, 2025•6 citations
We observe quantum beats with periodic revivals due to nonlinear spacing of Zeeman levels in the ground state of potassium atoms, and demonstrate their synchronous optical pumping by double modulation of the pumping light at the Larmor frequency and the revival frequency. We show that synchronous pumping increases the degree of spin polarization by a factor of 4. As a practical example, we explore the application of this double-modulation technique to atomic magnetometers operating in the geomagnetic field range, and find that it can increase the sensitivity and reduce magnetic-field-orientation-dependent measurement errors endemic to alkali-metal magnetometers.
Introduction Soon after the development of optical magnetometers based on the radio-optical double resonance method (see Chapter 4), it was realized by Bell and Bloom [1] that an alternative method for optical magnetometry was to modulate the light used for optical pumping at a frequency resonant with the Larmor precession of atomic spins. In a Bell-Bloom optical magnetometer, circularly polarized light resonant with an atomic transition propagates through an atomic vapor along a direction transverse to a magnetic field B . Atomic spins immersed in B precess at the Larmor frequency Ω L , and when the light intensity is modulated at Ω m = Ω L , a resonance in the transmitted light intensity is observed. The essential ideas of the Bell–Bloom optical magnetometer are reviewed in Chapter 1 (Section 1.2), and can be summarized in terms of what Bell and Bloom termed optically driven spin precession: in analogy with a driven harmonic oscillator, in a magnetic field B atomic spins precess at a natural frequency equal to Ω L and the light acts as a driving force oscillating at the modulation frequency Ω m . From another point of view, the Bell-Bloom optical magnetometer can be described in terms of synchronous optical pumping: when Ω m = Ω L , there is a “stroboscopic” resonance in which atoms are optically pumped into a spin state stationary in the frame rotating with Ω L . Depending on the details of the atomic structure, the spin state stationary in the rotating frame can be either a dark state that does not interact with the modulated light or a bright state for which the strength of the light–atom interaction is increased.
Introduction Shortly after the inception of atomic magnetometry, alkali-vapor magnetometers were being used to measure the Earth's magnetic field to unprecedented precision. During the same era, Bell and Bloom first demonstrated all-optical atomic magnetometry through synchronous optical pumping [1] (see Chapters 1 and 6). In this approach, optical-pumping light is frequency- or amplitude-modulated at harmonics of the Larmor frequency ω L to generate a precessing spin polarization within an alkali vapor at finite magnetic field [2, 3]. Although this technique received considerable attention from the atomic physics community for its applicability to optical pumping experiments, Earth's-field alkali-vapor atomic magnetometers continued to rely on radiofrequency (RF) field excitation for several decades (see Chapter 4). Upon the advent of diode lasers addressing alkali and metastable helium transitions, synchronously pumped magnetometers experienced a revival beginning in the late 1980s. In recent years, such magnetometers have found applications in nuclear magnetic resonance detection [4] (see also Chapter 14), quantum control experiments [5], and chip-scale devices intended for spacecraft use [6] (see also Chapters 7 and 15). All-optical magnetometers possess several advantages over devices that employ RF coils. RF-driven magnetometers can suffer from cross-talk if two sensors are placed in close proximity, since the AC magnetic field driving resonance in one vapor cell can adversely affect the other. All-optical magnetometers are free from such interference. When operated in self-oscillating mode [7], RF-driven magnetometers require an added ±90° electronic phase shift in the feedback loop to counter the intrinsic phase shift between the RF field and the probe-beam modulation.
We investigate the polarization modulation between two linear orthogonal states of the laser beam that synchronously pumps time-dependent atomic alignment in caesium atoms exposed to a static magnetic field. Because of the atomic alignment symmetry two independent groups of resonances can be distinguished in the transmitted light: when modulation frequency matches either the Larmor frequency or its second harmonics, ${\ensuremath{\omega}}_{L}$ and $2{\ensuremath{\omega}}_{L}$, respectively. We report on our experiments, and discuss a model that perfectly reproduces the observed spectra. We have observed that the amplitudes and linewidths of resonances at ${\ensuremath{\omega}}_{L}$ and $2{\ensuremath{\omega}}_{L}$ show magnetic-field direction dependence. This peculiar behavior makes our approach interesting for future application to atomic magnetometry, in view of a dead-zone free high-sensitivity magnetometer.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
Highly sensitive magnetic field measurements are desirable for medical diagnoses and imaging, as well as research in geomagnetism and fundamental physics. Atomic magnetometers measure the Larmor frequency of an alkali vapor, and their sensitivity depends on generating a high degree of ground-state coherence in the atomic population via optical pumping. This study uses an electro-optic frequency comb to probe a broad spectral region, yielding measurements of the Larmor frequency that are both temporally and spectrally resolved. The techniques developed here allow real-time analysis of the degree of polarization of the atomic ensemble, and the avenues by which this polarization is probed.
Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.