Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:physics/0608212 · Journal of the Physical Society of Japan

Improved Frequency Measurement of a One-Dimensional Optical Lattice Clock with a Spin-Polarized Fermionic87Sr Isotope

Masao Takamoto, Feng-Lei Hong, Ryoichi Higashi, Yasuhisa Fujii, Michito Imae, Hidetoshi Katori

Published Oct 10, 2006• 125 citations
arXivHTMLPDF

Abstract

We demonstrate a one-dimensional optical lattice clock with a spin-polarized fermionic isotope designed to realize a collision-shift-free atomic clock with neutral atom ensembles. To reduce systematic uncertainties, we developed both Zeeman shift and vector light-shift cancellation techniques. By introducing both an H-maser and a Global Positioning System (GPS) carrier phase link, the absolute frequency of the $^1S_0(F=9/2) - {}^3P_0(F=9/2)$ clock transition of the $^{87}$Sr optical lattice clock is determined as 429,228,004,229,875(4) Hz, where the uncertainty is mainly limited by that of the frequency link. The result indicates that the Sr lattice clock will play an important role in the scope of the redefinition of the ``second'' by optical frequency standards.

DOI
10.1143/jpsj.75.104302

Related papers

Three-dimensional optical lattice clock with bosonic Sr 88 atoms

Tomoya Akatsuka, Masao Takamoto, Hidetoshi Katori

We present detailed analyses of our recent experiment on the three-dimensional (3D) optical lattice clock with bosonic $^{88}\mathrm{Sr}$ atoms in which the collisional frequency shift was suppressed by applying a single-occupancy lattice. Frequency shifts in magnetically induced spectroscopy on the ${}^{1}{S}_{0}--{}^{3}{P}_{0}$ clock transition ($\ensuremath{\lambda}=698$ nm) of $^{88}\mathrm{Sr}$ were experimentally investigated by referencing a one-dimensional (1D) lattice clock based on spin-polarized $^{87}\mathrm{Sr}$ atoms. We discuss that the clock stability is limited by the current laser stability as well as the experimental sequence of the clock operation, which may be improved to ${\ensuremath{\sigma}}_{y}(\ensuremath{\tau})=2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}/\sqrt{\ensuremath{\tau}}$ by optimizing the cycle time of the clock operation.

Physical Review A•Feb 4, 2010•79 citations

One-Dimensional Optical Lattice Clock with a Fermionic171Yb Isotope

Takuya Kohno, Masami Yasuda, Kazumoto Hosaka +3 more

We demonstrate a one-dimensional optical lattice clock with ultracold 171 Yb atoms, which is free from the linear Zeeman effect. The absolute frequency of the 1 S 0 ( F = 1/2)– 3 P 0 ( F = 1/2) clock transition in 171 Yb is determined to be 518 295 836 590 864(28) Hz with respect to the SI second.

arXiv:0906.3664•Applied Physics Express•Jun 19, 2009•109 citations

Development of an Yb optical lattice clock using a fermionic isotope

Masami Yasuda, Takuya Kohno, Kazumoto Hosaka +5 more

We have developed a one-dimensional optical lattice clock with ultracold 171Yb atoms. The absolute frequency of the 1S0(F = 1/2) - 3P0(F = 1/2) clock transition in 171Yb is determined to be 518 295 836 590 864(28) Hz with respect to the SI second. Details of the experimental setups and atom trapping results are also described.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 20, 2009•0 citations

Clock with 8 × 10 − 19 Systematic Uncertainty

Alexander Aeppli, Kyungtae Kim, William Warfield +2 more

We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.

arXiv:2403.10664•Physical Review Letters•Jul 10, 2024•211 citations

Optical Lattice Clock with Spin-1/2 Ytterbium Atoms

N. Lemke

An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.

•Jan 1, 2012•7 citations

Operating a 87 Sr optical lattice clock with high precision and at high density

Matthew D. Swallows, Michael J. Martin, Michael Bishof +5 more

We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-(16) fractional frequency level. An upgraded laser system has recently been constructed in our lab which may allow the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. To take full advantage of these improvements, it will be necessary to operate a lattice clock with a large number of atoms, and systematic frequency shifts resulting from atomic interactions will become increasingly important. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms and describe a novel method by which such systematic effects can be suppressed.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2012•46 citations
We demonstrate a one-dimensional optical lattice clock with a spin-polarized fermionic isotope designed to realize a collision-shift-free atomic clock with neutral atom ensembles. To reduce systematic uncertainties, we developed both Zeeman shift and vector light-shift cancellation techniques. By introducing both an H-maser and a Global Positioning System (GPS) carrier phase link, the absolute frequency of the 1S0(F=9/2)−3P0(F=9/2)^1S_0(F=9/2) - {}^3P_0(F=9/2)1S0​(F=9/2)−3P0​(F=9/2) clock transition of the 87^{87}87Sr optical lattice clock is determined as 429,228,004,229,875(4) Hz, where the uncertainty is mainly limited by that of the frequency link. The result indicates that the Sr lattice clock will play an important role in the scope of the redefinition of the ``second'' by optical frequency standards.
We present detailed analyses of our recent experiment on the three-dimensional (3D) optical lattice clock with bosonic 88Sr^{88}\mathrm{Sr}88Sr atoms in which the collisional frequency shift was suppressed by applying a single-occupancy lattice. Frequency shifts in magnetically induced spectroscopy on the 1S0−−3P0{}^{1}{S}_{0}--{}^{3}{P}_{0}1S0​−−3P0​ clock transition ($\ensuremath{\lambda}=698$ nm) of 88Sr^{88}\mathrm{Sr}88Sr were experimentally investigated by referencing a one-dimensional (1D) lattice clock based on spin-polarized 87Sr^{87}\mathrm{Sr}87Sr atoms. We discuss that the clock stability is limited by the current laser stability as well as the experimental sequence of the clock operation, which may be improved to ${\ensuremath{\sigma}}_{y}(\ensuremath{\tau})=2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}/\sqrt{\ensuremath{\tau}}$ by optimizing the cycle time of the clock operation.
We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.
An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.
We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-(16) fractional frequency level. An upgraded laser system has recently been constructed in our lab which may allow the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. To take full advantage of these improvements, it will be necessary to operate a lattice clock with a large number of atoms, and systematic frequency shifts resulting from atomic interactions will become increasingly important. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms and describe a novel method by which such systematic effects can be suppressed.