Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:physics/0604054 · Conference on Lasers and Electro-Optics

Enhanced production of coherent pulsed radiation at 125 nm: The route towards a tabletop VUV laser

Sebastien Chénais, Sébastien Forget, M. C. Castex

Published Jan 1, 2006• 0 citations
arXivHTMLPDF

Abstract

A novel approach is used to enhance by nearly two orders of magnitude the conversion efficiency of a 125 nm-coherent source, based on four-wave mixing in room-temperature mercury vapor. Saturation issues are observed and discussed.
DOI
10.1109/cleo.2006.4627721

Related papers

High-efficiency, energy-scalable, coherent 130-nm source by four-wave mixing in Hg vapor

C. H. Muller, Arlee V. Smith, Dennis D. Lowenthal +1 more

Coherent vacuum-ultraviolet (VUV) pulses with energy of 1.1 mJ, 2.2-nsec pulse length (2 MW cm−2 unfocused), and measured bandwidth ≤0.1 cm−1 have been achieved at 130 nm from four-wave mixing in Hg vapor. Conversion efficiencies of 5% have been demonstrated in a collimated beam geometry over 1-m interaction lengths. These high efficiencies are made possible by using two-photon-resonant sum-frequency mixing through the Hg 71S level. The experimental facility assembled to produce this efficient VUV source is described, and a comparison between experimental measurements and theory is provided.

Optics Letters•Aug 1, 1988•44 citations

Enhanced production of coherent vuv radiation by four-wave mixing in Sr vapor

Gary C. Bjorklund, John E. Bjorkholm, Richard R. Freeman +1 more

Significant enhancement of the unsaturated conversion efficiencies of four-wave sum frequency mixing processes involving autoionizing states in Sr vapor is obtained by utilizing the 5s7s 1S0 two-photon channel and phase matching by frequency adjustment. Extrapolation to low power levels indicates that production of cw vuv radiation may be possible. A saturation effect arising from depletion of one of the fundamental beams by two-photon absorption is observed.

Applied Physics Letters•Sep 1, 1977•35 citations

Generation of high-brightness coherent radiation in the vacuum ultraviolet by four-wave parametric oscillation in mercury vapor

Jeffrey Bokor, Richard R. Freeman, R. L. Panock +1 more

Coherent radiation at several wavelengths in the vacuum ultraviolet (VUV) has been generated by four-wave parametric oscillation in mercury vapor. When a powerful ultraviolet pump laser of frequency omega(p) is tuned to a two-photon resonance, VUV signal photons at frequency omega(s), as well as idler photons at frequency omega(i), are generated such that omega(s) + omega(i) = 2omega(p). A frequency-doubled dye laser tuned to two-photon resonance with the 6s6d(1)D(2) level near 280.3 nm produced output at 184.9 and 143.5 nm. A tunable krypton fluoride excimer laser tuned to two-photon resonance with the 6s10s (1)S(0) level near 248.7 nm produced output at 140.1, 130.7, 130.1, 125.9, and 125.0 nm. Approximately 1-microJ, 200-W pulses were observed at 143.5 and 125.9 nm.

Optics Letters•Apr 1, 1981•62 citations

Polarization properties of coherent VUV light at 125 nm generated by sum-frequency four-wave mixing in mercury

L. Museur, C. Olivero, Damien Riedel +1 more

Applied Physics B•Apr 1, 2000•17 citations

Generation of continuously tunable coherent vacuum-ultraviolet radiation in Cd vapor

Kenzo Miyazaki, Hirofumi Sakai, Takuzo Sato

Continuously tunable coherent vacuum-ultraviolet (VUV) radiation has been generated in the 128.7-135.3-nm region by two-photon resonant four-wave mixing in Cd vapor. The generated VUV has no spectral structure over the tuning range and indicates that Cd vapor is an efficient nonlinear medium for frequency conversion.

Optics Letters•Oct 1, 1984•22 citations

Continuous Wave Coherent Lyman- α Radiation

K. S. E. Eikema, J. Walz, Theodor W. Hänsch

We describe the first coherent generation of continuous wave radiation at 121.56 nm. A yield of $3\ifmmode\times\else\texttimes\fi{}{10}^{8}\mathrm{photons}/\mathrm{sec}$ (0.5 nW) has been achieved by four-wave mixing in mercury vapor. This continuous Lyman- $\ensuremath{\alpha}$ source could be used for laser cooling and precision spectroscopy of both hydrogen and antihydrogen.

Physical Review Letters•Nov 8, 1999•94 citations
Coherent vacuum-ultraviolet (VUV) pulses with energy of 1.1 mJ, 2.2-nsec pulse length (2 MW cm−2 unfocused), and measured bandwidth ≤0.1 cm−1 have been achieved at 130 nm from four-wave mixing in Hg vapor. Conversion efficiencies of 5% have been demonstrated in a collimated beam geometry over 1-m interaction lengths. These high efficiencies are made possible by using two-photon-resonant sum-frequency mixing through the Hg 71S level. The experimental facility assembled to produce this efficient VUV source is described, and a comparison between experimental measurements and theory is provided.
Coherent radiation at several wavelengths in the vacuum ultraviolet (VUV) has been generated by four-wave parametric oscillation in mercury vapor. When a powerful ultraviolet pump laser of frequency omega(p) is tuned to a two-photon resonance, VUV signal photons at frequency omega(s), as well as idler photons at frequency omega(i), are generated such that omega(s) + omega(i) = 2omega(p). A frequency-doubled dye laser tuned to two-photon resonance with the 6s6d(1)D(2) level near 280.3 nm produced output at 184.9 and 143.5 nm. A tunable krypton fluoride excimer laser tuned to two-photon resonance with the 6s10s (1)S(0) level near 248.7 nm produced output at 140.1, 130.7, 130.1, 125.9, and 125.0 nm. Approximately 1-microJ, 200-W pulses were observed at 143.5 and 125.9 nm.