Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:physics/0512201 · Physical Review Letters

Hyperpolarizability Effects in a Sr Optical Lattice Clock

Anders Brusch, Rodolphe Le Targat, Xavier Baillard, Mathilde Fouché, P. Lemonde

Published Mar 16, 2006• 120 citations
arXivHTMLPDF

Abstract

We report the observation of a higher-order frequency shift due to the trapping field in a (87)Sr optical lattice clock. We show that, at the magic wavelength of the lattice, where the first-order term cancels, the higher-order shift will not constitute a limitation to the fractional accuracy of the clock at a level of 10(-18). This result is achieved by operating the clock at very high trapping intensity up to 400 kW/cm(2) and by a specific study of the effect of the two two-photon transitions near the magic wavelength.

DOI
10.1103/physrevlett.96.103003

Related papers

Hyperpolarizability effects and accuracy evaluation of a 87Sr optical lattice clock

Rodolphe Le Targat, Anders Brusch, Xavier Baillard +4 more

The authors report the observation of the hyperpolarizability frequency shift due to the trapping field in a87Sr optical lattice clock. The authors show that at the magic wavelength of the lattice, where the first order term cancels, this higher order shift will not constitute a limitation to the fractional accuracy of the clock down to the 10-18level. This result is achieved by operating the clock at very high trapping intensity up to 400 kW/cm2and by a specific study of the effect of the two two-photon transitions near the magic wavelength. The authors also report an accurate frequency measurement of the clock transition. The frequency is determined to be v1S0-3P0= 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical clocks with neutral atoms in free fall

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2006•1 citation

Optical Lattice Polarization Effects on Hyperpolarizability of Atomic Clock Transitions

А. В. Тайченачев, Valeriy I. Yudin, Vitalii D Ovsiannikov +1 more

The light-induced frequency shift due to hyperpolarizability (i.e., terms of second-order in intensity) is studied for a forbidden optical transition, J = 0 --> J = 0. A simple universal dependence on the field ellipticity is obtained. This result allows minimization of the second-order light shift with respect to the field polarization for optical lattices operating at a magic wavelength (at which the first-order shift vanishes). We show the possibility for the existence of a magic elliptical polarization, for which the second-order frequency shift vanishes. The optimal polarization of the lattice field can be either linear, circular, or magic elliptical. The obtained results could improve the accuracy of lattice-based atomic clocks.

arXiv:physics/0606214•Physical Review Letters•Oct 25, 2006•31 citations

Prospects for Optical Clocks with a Blue-Detuned Lattice

Masao Takamoto, Hidetoshi Katori, S. I. Marmo +2 more

We investigated the properties of optical lattice clocks operated with a repulsive light-shift potential. The magic wavelength, where light-shift perturbation for the clock transition cancels, was experimentally determined to be 389.889(9) nm for 87Sr. The hyperpolarizability effects on the clock transition were investigated theoretically. With minimal trapping field perturbation provided by the blue-detuned lattice, the fractional uncertainty due to the hyperpolarizability effects was found to be 2x10;{-19} in the relevant clock transition.

Physical Review Letters•Feb 10, 2009•77 citations

Multipolar and higher-order lattice shifts in the Sr and Mg clocks

Fang-Fei Wu, Yongbo Tang, Ting-Yun Shi +1 more

The progress in optical clock with uncertainty at a level of $10^{-18}$ requires unprecedented precision in estimating the contribution of multipolar and higher-order effects of atom-field interactions. Previous theoretical and experimental results of dynamic multipolar polarizabilities and hyperpolarizabilities at the 813 nm magic wavelength of the Sr clock differ substantially. We employ the sum-over-states method to calculate dynamic multipolar polarizabilities and hyperpolarizabilities for the Sr and Mg clocks. Our differential dynamic hyperpolarizability at the magic wavelength of 813.4280(5) nm for the Sr clock is $-2.09(43)\times10^{7}$ a.u., which agrees well with the recent theoretical and measurement results. Our differential multipolar polarizability of the Sr clock is $2.68(94)\times 10^{-5}$ a.u., which is consistent with the theoretical work of Porsev {\em et al.} [Phys. Rev. Lett. 120, 063204 (2018)], but different from recent measurement of Ushijima {\em et al.} [Phys. Rev. Lett. 121, 263202 (2018)]. In addition, the lattice light shifts as the detuning and trap depth changed are studied in detail by using present multipolar polarizability and hyperpolarizability. It illustrates that for the Mg clock, there exists a distinctive operational lattice depth of $5.3(1)E_R$ that allows the total light shift reduced to less than $1\times 10^{-18}$ over the trap depth variation of $4.1E_R<U<6.4E_R$.

•Jun 5, 2019•0 citations

Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock

Roger C. Brown, Nate Phillips, K. Beloy +11 more

Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.

arXiv:1708.08829•Physical Review Letters•Dec 19, 2017•101 citations

Higher order frequency shifts in a Sr optical lattice clock

Rodolphe Le Targat, X. Brusch, Xavier Baillard +2 more

We experimentally study higher order frequency shifts due to the lattice in a87Sr optical lattice clock. We show that this effect will not limit the fractional accuracy of the clock at the 10–18 level.

Conference on Lasers and Electro-Optics•Jan 1, 2006•1 citation
We report the observation of a higher-order frequency shift due to the trapping field in a (87)Sr optical lattice clock. We show that, at the magic wavelength of the lattice, where the first-order term cancels, the higher-order shift will not constitute a limitation to the fractional accuracy of the clock at a level of 10(-18). This result is achieved by operating the clock at very high trapping intensity up to 400 kW/cm(2) and by a specific study of the effect of the two two-photon transitions near the magic wavelength.
The authors report the observation of the hyperpolarizability frequency shift due to the trapping field in a87Sr optical lattice clock. The authors show that at the magic wavelength of the lattice, where the first order term cancels, this higher order shift will not constitute a limitation to the fractional accuracy of the clock down to the 10-18level. This result is achieved by operating the clock at very high trapping intensity up to 400 kW/cm2and by a specific study of the effect of the two two-photon transitions near the magic wavelength. The authors also report an accurate frequency measurement of the clock transition. The frequency is determined to be v1S0-3P0= 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical clocks with neutral atoms in free fall
The light-induced frequency shift due to hyperpolarizability (i.e., terms of second-order in intensity) is studied for a forbidden optical transition, J = 0 --> J = 0. A simple universal dependence on the field ellipticity is obtained. This result allows minimization of the second-order light shift with respect to the field polarization for optical lattices operating at a magic wavelength (at which the first-order shift vanishes). We show the possibility for the existence of a magic elliptical polarization, for which the second-order frequency shift vanishes. The optimal polarization of the lattice field can be either linear, circular, or magic elliptical. The obtained results could improve the accuracy of lattice-based atomic clocks.
We investigated the properties of optical lattice clocks operated with a repulsive light-shift potential. The magic wavelength, where light-shift perturbation for the clock transition cancels, was experimentally determined to be 389.889(9) nm for 87Sr. The hyperpolarizability effects on the clock transition were investigated theoretically. With minimal trapping field perturbation provided by the blue-detuned lattice, the fractional uncertainty due to the hyperpolarizability effects was found to be 2x10;{-19} in the relevant clock transition.
The progress in optical clock with uncertainty at a level of 10−1810^{-18}10−18 requires unprecedented precision in estimating the contribution of multipolar and higher-order effects of atom-field interactions. Previous theoretical and experimental results of dynamic multipolar polarizabilities and hyperpolarizabilities at the 813 nm magic wavelength of the Sr clock differ substantially. We employ the sum-over-states method to calculate dynamic multipolar polarizabilities and hyperpolarizabilities for the Sr and Mg clocks. Our differential dynamic hyperpolarizability at the magic wavelength of 813.4280(5) nm for the Sr clock is −2.09(43)×107-2.09(43)\times10^{7}−2.09(43)×107 a.u., which agrees well with the recent theoretical and measurement results. Our differential multipolar polarizability of the Sr clock is 2.68(94)×10−52.68(94)\times 10^{-5}2.68(94)×10−5 a.u., which is consistent with the theoretical work of Porsev {\em et al.} [Phys. Rev. Lett. 120, 063204 (2018)], but different from recent measurement of Ushijima {\em et al.} [Phys. Rev. Lett. 121, 263202 (2018)]. In addition, the lattice light shifts as the detuning and trap depth changed are studied in detail by using present multipolar polarizability and hyperpolarizability. It illustrates that for the Mg clock, there exists a distinctive operational lattice depth of 5.3(1)ER5.3(1)E_R5.3(1)ER​ that allows the total light shift reduced to less than 1×10−181\times 10^{-18}1×10−18 over the trap depth variation of 4.1ER<U<6.4ER4.1E_R<U<6.4E_R4.1ER​<U<6.4ER​.
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.