arXiv:physics/0205049 · Physical Review Letters

Optical Clock with Ultracold Neutral Atoms

G. Wilpers, T. Binnewies, C. Degenhardt, Uwe Sterr, J. Helmcke, F. Riehle

Published Nov 15, 2002• 145 citations
arXivHTMLPDF

Abstract

We demonstrate how to realize an optical clock with neutral atoms that is competitive to the currently best single ion optical clocks in accuracy and superior in stability. Using ultracold atoms in a Ca optical frequency standard, we show how to reduce the relative uncertainty to below 10(-15). We observed atom interferences for stabilization of the laser to the clock transition with a visibility of 0.36, which is 70% of the ultimate limit achievable with atoms at rest. A novel scheme was applied to detect these atom interferences with the prospect to reach the quantum projection noise limit at an exceptional low instability of 4 x 10(-17) in 1 s.

DOI
10.1103/physrevlett.89.230801

Related papers

Single-ion, transportable optical atomic clocks

Marion Delehaye, Clément Lacroûte

For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.

arXiv:1804.02168•Journal of Modern Optics•Mar 7, 2018•42 citations

Ultracold atoms and precise time standards

Gretchen K. Campbell, William D. Phillips

Experimental techniques of laser cooling and trapping, along with other cooling techniques, have produced gaseous samples of atoms so cold that they are, for many practical purposes, in the quantum ground state of their centre-of-mass motion. Such low velocities have virtually eliminated effects such as Doppler shifts, relativistic time dilation and observation-time broadening that previously limited the performance of atomic frequency standards. Today, the best laser-cooled, caesium atomic fountain, microwave frequency standards realize the International System of Units (SI) definition of the second to a relative accuracy of ≈3×10(-16). Optical frequency standards, which do not realize the SI second, have even better performance: cold neutral atoms trapped in optical lattices now yield relative systematic uncertainties of ≈1×10(-16), whereas cold-trapped ions have systematic uncertainties of 9×10(-18). We will discuss the current limitations in the performance of neutral atom atomic frequency standards and prospects for the future.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Sep 19, 2011•29 citations

Extending the fundamental limit of atomic clock stability

Ravid Shaniv, Ayush Agrawal, David B. Hume

Optical atomic clocks have been rapidly developing in recent decades, resulting in major improvements in both precision and accuracy. As a result, they have become instrumental in multiple areas of applied and fundamental research. Despite all atomic frequency references having more than two energy-levels, the commonly used model for evaluating their ultimate limits assumes a two-level atom. This leads to frequency interrogation protocols and theoretical stability bounds that are suboptimal for a true multi-level atom. The most fundamental stability bound assumes two noise sources - quantum projection noise and spontaneous decay from the excited state. In this work, we analyze a model that includes these noise types and is generalized beyond the two-level assumption, where spontaneous decay can branch to more than a single ground state. This model allows for detection and exclusion of atomic frequency interrogations in which the atom decayed, leading to a frequency stability improvement of up to $\approx 4.5 \text{ dB}$ compared with the two-level model. Furthermore, we identify an even greater stability enhancement of $\approx 5.4 \text{ dB}$ for frequency comparisons between atoms in an odd parity Bell state. These enhancements are particularly relevant for the numerous trapped-ion optical clock species that operate close to lifetime-limited stability. We calculate new stability limits for those cases and provide a detailed experimental protocol for frequency interrogation with an $^{27}\text{Al}^{+}$ optical ion clock.

physics.atom-phCross-listedarXiv:2604.01099•Apr 2, 2026•0 citations

Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty

Moustafa Abdel Hafiz, Piotr Ablewski, Ali Al-Masoudi +42 more

There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the 10−18 range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with 1×10−18 uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.

arXiv:1906.11495•Jan 1, 2019•14 citations

An Atomic-Array Optical Clock with Single-Atom Readout

Ivaylo S. Madjarov, Alexandre Cooper, Adam L. Shaw +5 more

Currently, the most accurate and stable clocks use optical interrogation of either a single ion or an ensemble of neutral atoms confined in an optical lattice.Here, we demonstrate a new optical clock system based on an array of individually trapped neutral atoms with single-atom readout, merging many of the benefits of ion and lattice clocks as well as creating a bridge to recently developed techniques in quantum simulation and computing with neutral atoms.We evaluate single-site-resolved frequency shifts and shortterm stability via self-comparison.Atom-by-atom feedback control enables direct experimental estimation of laser noise contributions.Results agree well with an ab initio Monte Carlo simulation that incorporates finite temperature, projective readout, laser noise, and feedback dynamics.Our approach, based on a tweezer array, also suppresses interaction shifts while retaining a short dead time, all in a comparatively simple experimental setup suited for transportable operation.These results establish the foundations for a third optical clock platform and provide a novel starting point for entanglement-enhanced metrology, quantum clock networks, and applications in quantum computing and communication with individual neutral atoms that require optical-clock-state control.

arXiv:1908.05619•Physical Review X•Dec 11, 2019•148 citations

Optical atomic clocks and the quest for ultrastable lasers

F. Riehle

Optical atomic clocks with fractional uncertainties around and below 10−17 [1] and fractional instabilities at one second interrogation time of below 10−15 [2] have outperformed the best microwave clocks like the cesium atomic clock. In optical atomic clocks a highly stable laser is used to interrogate optical transitions in laser-cooled atoms, ions, or molecules. The increase in accuracy and stability of the optical atomic clocks results from the increased line quality factor Q= ν/Δν given by the five orders of magnitude higher frequency of optical transitions as compared to the transition relevant in the microwave domain. To utilize this potential it is furthermore necessary to realize a suitable narrow linewidth of the interrogated line. The linewidth of any optical transition is given by the different broadening mechanisms of the respective quantum transition relevant for particular interrogation process as well as by the coherence properties of the interrogating laser.

Frontiers in Optics•Jan 1, 2013•1 citation
We demonstrate how to realize an optical clock with neutral atoms that is competitive to the currently best single ion optical clocks in accuracy and superior in stability. Using ultracold atoms in a Ca optical frequency standard, we show how to reduce the relative uncertainty to below 10(-15). We observed atom interferences for stabilization of the laser to the clock transition with a visibility of 0.36, which is 70% of the ultimate limit achievable with atoms at rest. A novel scheme was applied to detect these atom interferences with the prospect to reach the quantum projection noise limit at an exceptional low instability of 4 x 10(-17) in 1 s.
For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.
Experimental techniques of laser cooling and trapping, along with other cooling techniques, have produced gaseous samples of atoms so cold that they are, for many practical purposes, in the quantum ground state of their centre-of-mass motion. Such low velocities have virtually eliminated effects such as Doppler shifts, relativistic time dilation and observation-time broadening that previously limited the performance of atomic frequency standards. Today, the best laser-cooled, caesium atomic fountain, microwave frequency standards realize the International System of Units (SI) definition of the second to a relative accuracy of ≈3×10(-16). Optical frequency standards, which do not realize the SI second, have even better performance: cold neutral atoms trapped in optical lattices now yield relative systematic uncertainties of ≈1×10(-16), whereas cold-trapped ions have systematic uncertainties of 9×10(-18). We will discuss the current limitations in the performance of neutral atom atomic frequency standards and prospects for the future.
Optical atomic clocks have been rapidly developing in recent decades, resulting in major improvements in both precision and accuracy. As a result, they have become instrumental in multiple areas of applied and fundamental research. Despite all atomic frequency references having more than two energy-levels, the commonly used model for evaluating their ultimate limits assumes a two-level atom. This leads to frequency interrogation protocols and theoretical stability bounds that are suboptimal for a true multi-level atom. The most fundamental stability bound assumes two noise sources - quantum projection noise and spontaneous decay from the excited state. In this work, we analyze a model that includes these noise types and is generalized beyond the two-level assumption, where spontaneous decay can branch to more than a single ground state. This model allows for detection and exclusion of atomic frequency interrogations in which the atom decayed, leading to a frequency stability improvement of up to ≈4.5 dB\approx 4.5 \text{ dB}≈4.5 dB compared with the two-level model. Furthermore, we identify an even greater stability enhancement of ≈5.4 dB\approx 5.4 \text{ dB}≈5.4 dB for frequency comparisons between atoms in an odd parity Bell state. These enhancements are particularly relevant for the numerous trapped-ion optical clock species that operate close to lifetime-limited stability. We calculate new stability limits for those cases and provide a detailed experimental protocol for frequency interrogation with an 27Al+^{27}\text{Al}^{+}27Al+ optical ion clock.
Guidelines for developing optical clocks with 10−1810^{-18}10−18 fractional frequency uncertainty
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the 10−18 range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with 1×10−18 uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
Currently, the most accurate and stable clocks use optical interrogation of either a single ion or an ensemble of neutral atoms confined in an optical lattice.Here, we demonstrate a new optical clock system based on an array of individually trapped neutral atoms with single-atom readout, merging many of the benefits of ion and lattice clocks as well as creating a bridge to recently developed techniques in quantum simulation and computing with neutral atoms.We evaluate single-site-resolved frequency shifts and shortterm stability via self-comparison.Atom-by-atom feedback control enables direct experimental estimation of laser noise contributions.Results agree well with an ab initio Monte Carlo simulation that incorporates finite temperature, projective readout, laser noise, and feedback dynamics.Our approach, based on a tweezer array, also suppresses interaction shifts while retaining a short dead time, all in a comparatively simple experimental setup suited for transportable operation.These results establish the foundations for a third optical clock platform and provide a novel starting point for entanglement-enhanced metrology, quantum clock networks, and applications in quantum computing and communication with individual neutral atoms that require optical-clock-state control.
Optical atomic clocks with fractional uncertainties around and below 10−17 [1] and fractional instabilities at one second interrogation time of below 10−15 [2] have outperformed the best microwave clocks like the cesium atomic clock. In optical atomic clocks a highly stable laser is used to interrogate optical transitions in laser-cooled atoms, ions, or molecules. The increase in accuracy and stability of the optical atomic clocks results from the increased line quality factor Q= ν/Δν given by the five orders of magnitude higher frequency of optical transitions as compared to the transition relevant in the microwave domain. To utilize this potential it is furthermore necessary to realize a suitable narrow linewidth of the interrogated line. The linewidth of any optical transition is given by the different broadening mechanisms of the respective quantum transition relevant for particular interrogation process as well as by the coherence properties of the interrogating laser.