arXiv:cond-mat/0702453 · Physical Review B

Nanosecond quantum state detection in a current-biased dc SQUID

Julien Claudon, Aurélien Fay, Emile Hoskinson, O. Buisson

Published Jul 13, 2007• 16 citations
arXivHTMLPDF

Abstract

This paper presents our procedure to measure the quantum state of a dc superconducting quantum interference device (SQUID) within a few nanoseconds, using an adiabatic dc flux pulse. Detection of the ground state is governed by standard macroscopic quantum tunneling (MQT) theory, with a small correction due to residual noise in the bias current. In the two-level limit, where the SQUID constitutes a phase qubit, an observed contrast of 0.54 indicates a significant loss in contrast compared to the MQT prediction. It is attributed to spurious depolarization (loss of excited state occupancy) during the leading edge of the adiabatic flux measurement pulse. We give a simple phenomenological relaxation model which is able to predict the observed contrast of multilevel Rabi oscillations for various microwave amplitudes.

DOI
10.1103/physrevb.76.024508

Related papers

Coherent Oscillations in a Superconducting Multilevel Quantum System

Julien Claudon, Franck Balestro, F. W. J. Hekking +1 more

We have observed coherent oscillations in a multilevel quantum system, formed by a current-biased dc SQUID. These oscillations have been induced by applying resonant microwave pulses of flux. Quantum measurement is performed by a nanosecond flux pulse that projects the final state onto one of two different voltage states of the dc SQUID, which can be read out. The number of quantum states involved in the coherent oscillations increases with increasing microwave power. The dependence of the oscillation frequency on microwave power deviates strongly from the linear regime expected for a two-level system and can be very well explained by a theoretical model taking into account the anharmonicity of the multilevel system.

arXiv:cond-mat/0405430•Physical Review Letters•Oct 26, 2004•108 citations

Decoherence processes in a current biased dc SQUID

Julien Claudon, Aurélien Fay, Laurent-Patrick Lévy +1 more

A current biased dc superconducting quantum interference device behaves as an anharmonic quantum oscillator controlled by a bias current and an applied magnetic flux. We consider here its two level limit consisting of the two lower energy states \ensuremath{\mid}0⟩ and \ensuremath{\mid}1⟩. We have measured energy relaxation times and microwave absorption for different bias currents and fluxes in the low microwave power limit. Decoherence times are extracted. The low frequency flux and current noise have been measured independently by analyzing the probability of current switching from the superconducting to the finite voltage state, as a function of applied flux. The high frequency part of the current noise is derived from the electromagnetic environment of the circuit. The decoherence of this quantum circuit can be fully accounted for by these current and flux noise sources.

arXiv:cond-mat/0601522•Physical Review B•May 5, 2006•19 citations

Evidence of Two-Dimensional Macroscopic Quantum Tunneling of a Current-Biased dc SQUID

Franck Balestro, Julien Claudon, Jukka P Pekola +1 more

The escape probability out of the superconducting state of a hysteretic dc SQUID has been measured at different values of the applied magnetic flux. At low temperatures, the escape current and the width of the probability distribution are temperature independent but they depend on flux. Experimental results do not fit the usual one-dimensional macroscopic quantum tunneling (MQT) law but are perfectly accounted for by the two-dimensional MQT behavior as we propose here. Near zero flux, our data confirms the recent MQT observation in a dc SQUID [Phys. Rev. Lett. 89, 98301 (2002)]].

arXiv:cond-mat/0308559•Physical Review Letters•Oct 6, 2003•40 citations

Phase coherent dynamics of a superconducting flux qubit with capacitive bias readout

Frank Deppe, M. Mariantoni, E. P. Menzel +7 more

We present a systematic study of the phase coherent dynamics of a superconducting three-Josephson-junction flux qubit. The qubit state is detected with the integrated-pulse method, which is a variant of the pulsed switching-dc-superconducting quantum interference device (SQUID) method. In this scheme, the dc SQUID bias current pulse is applied via a capacitor instead of a resistor, giving rise to a narrow bandpass instead of a pure low-pass filter configuration of the electromagnetic environment. Measuring one and the same qubit with both setups allows a direct comparison. With the capacitive method about four times faster switching pulses and an increased visibility are achieved. Furthermore, the deliberate engineering of the electromagnetic environment, which minimizes the noise due to the bias circuit, is facilitated. Right at the degeneracy point, the qubit coherence is limited by energy relaxation. We find two main noise contributions. White noise limits the energy relaxation and contributes to the dephasing far from the degeneracy point. $1∕f$ noise is the dominant source of dephasing in the direct vicinity of the optimal point. The influence of $1∕f$ noise is also supported by nonrandom beatings in the Ramsey and spin echo decay traces. Numeric simulations of a coupled qubit-oscillator system indicate that these beatings are due to the resonant interaction of the qubit with at least one pointlike fluctuator, coupled especially strongly to the qubit.

arXiv:0710.4455•Physical Review B•Dec 4, 2007•38 citations

Quantum state detection of a superconducting flux qubit using a dc-SQUID in the inductive mode

Adrian Lupaşcu, C. J. P. M. Harmans, Johan E. Mooij

We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.

arXiv:cond-mat/0410730•Physical Review B•May 13, 2005•25 citations

Thermal activation and macroscopic quantum tunneling in a DC SQUID

Fred Sharifi, J. L. Gavilano, Dale J. Van Harlingen

The authors report measurements of the transition rate from zero-voltage metastable minima in the two-dimensional potential of a DC SQUID (superconducting quantum interference device) as a function of applied flux and temperature. A crossover is observed from thermally activated escape to macroscopic quantum tunneling at a critical temperature that is a strong function of the bias flux. The macroscopic quantum tunneling rate is substantially reduced by damping, which also broadens the crossover region. The authors unexpectedly observed thermal rates that are significantly suppressed from those predicted by the classical two-dimensional thermal activation model, as if the potential barrier for activation were effectively enhanced. They discuss possible explanations for this result, based on the interaction of the macroscopic degrees of freedom in the device and energy level quantization effects.>

IEEE Transactions on Magnetics•Mar 1, 1989•3 citations
This paper presents our procedure to measure the quantum state of a dc superconducting quantum interference device (SQUID) within a few nanoseconds, using an adiabatic dc flux pulse. Detection of the ground state is governed by standard macroscopic quantum tunneling (MQT) theory, with a small correction due to residual noise in the bias current. In the two-level limit, where the SQUID constitutes a phase qubit, an observed contrast of 0.54 indicates a significant loss in contrast compared to the MQT prediction. It is attributed to spurious depolarization (loss of excited state occupancy) during the leading edge of the adiabatic flux measurement pulse. We give a simple phenomenological relaxation model which is able to predict the observed contrast of multilevel Rabi oscillations for various microwave amplitudes.
We have observed coherent oscillations in a multilevel quantum system, formed by a current-biased dc SQUID. These oscillations have been induced by applying resonant microwave pulses of flux. Quantum measurement is performed by a nanosecond flux pulse that projects the final state onto one of two different voltage states of the dc SQUID, which can be read out. The number of quantum states involved in the coherent oscillations increases with increasing microwave power. The dependence of the oscillation frequency on microwave power deviates strongly from the linear regime expected for a two-level system and can be very well explained by a theoretical model taking into account the anharmonicity of the multilevel system.
A current biased dc superconducting quantum interference device behaves as an anharmonic quantum oscillator controlled by a bias current and an applied magnetic flux. We consider here its two level limit consisting of the two lower energy states \ensuremath{\mid}0⟩ and \ensuremath{\mid}1⟩. We have measured energy relaxation times and microwave absorption for different bias currents and fluxes in the low microwave power limit. Decoherence times are extracted. The low frequency flux and current noise have been measured independently by analyzing the probability of current switching from the superconducting to the finite voltage state, as a function of applied flux. The high frequency part of the current noise is derived from the electromagnetic environment of the circuit. The decoherence of this quantum circuit can be fully accounted for by these current and flux noise sources.
The escape probability out of the superconducting state of a hysteretic dc SQUID has been measured at different values of the applied magnetic flux. At low temperatures, the escape current and the width of the probability distribution are temperature independent but they depend on flux. Experimental results do not fit the usual one-dimensional macroscopic quantum tunneling (MQT) law but are perfectly accounted for by the two-dimensional MQT behavior as we propose here. Near zero flux, our data confirms the recent MQT observation in a dc SQUID [Phys. Rev. Lett. 89, 98301 (2002)]].
We present a systematic study of the phase coherent dynamics of a superconducting three-Josephson-junction flux qubit. The qubit state is detected with the integrated-pulse method, which is a variant of the pulsed switching-dc-superconducting quantum interference device (SQUID) method. In this scheme, the dc SQUID bias current pulse is applied via a capacitor instead of a resistor, giving rise to a narrow bandpass instead of a pure low-pass filter configuration of the electromagnetic environment. Measuring one and the same qubit with both setups allows a direct comparison. With the capacitive method about four times faster switching pulses and an increased visibility are achieved. Furthermore, the deliberate engineering of the electromagnetic environment, which minimizes the noise due to the bias circuit, is facilitated. Right at the degeneracy point, the qubit coherence is limited by energy relaxation. We find two main noise contributions. White noise limits the energy relaxation and contributes to the dephasing far from the degeneracy point. 1∕f1∕f1∕f noise is the dominant source of dephasing in the direct vicinity of the optimal point. The influence of 1∕f1∕f1∕f noise is also supported by nonrandom beatings in the Ramsey and spin echo decay traces. Numeric simulations of a coupled qubit-oscillator system indicate that these beatings are due to the resonant interaction of the qubit with at least one pointlike fluctuator, coupled especially strongly to the qubit.
We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.
The authors report measurements of the transition rate from zero-voltage metastable minima in the two-dimensional potential of a DC SQUID (superconducting quantum interference device) as a function of applied flux and temperature. A crossover is observed from thermally activated escape to macroscopic quantum tunneling at a critical temperature that is a strong function of the bias flux. The macroscopic quantum tunneling rate is substantially reduced by damping, which also broadens the crossover region. The authors unexpectedly observed thermal rates that are significantly suppressed from those predicted by the classical two-dimensional thermal activation model, as if the potential barrier for activation were effectively enhanced. They discuss possible explanations for this result, based on the interaction of the macroscopic degrees of freedom in the device and energy level quantization effects.>