Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Intensity correlations in optical nonlinear processes by photon counting techniques

F. Davidson, J. Klebba, Frank K. Tittel

Published Jan 1, 1970• 0 citations
OpenAlex

Abstract

Intensity correlations in optical parametric noise and second harmonic generation measured by two photon delayed coincidence counting

Related papers

Noise in Classical and Quantum Photon-Correlation Imaging

Bahaa E. A. Saleh, Malvin Carl Teich

Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.

SPIE eBooks•Mar 16, 2010•3 citations

QUANTUM CORRELATIONS IN NONLINEAR OPTICAL SIGNALS

Rupamanjari Ghosh

•Jan 1, 1994•2 citations

Photon correlation effects in second harmonic generation

Yujiang Qu, Surendra Singh

Optics Communications•Jun 1, 1992•32 citations

Generation of polarization entangled photon pairs at telecommunication wavelength using cascaded χ^(2) processes in a periodically poled LiNbO_3 ridge waveguide

Shin Arahira, Naoto Namekata, Tadashi Kishimoto +2 more

We report the generation of high-purity correlated photon-pairs and polarization entanglement in a 1.5 μm telecommunication wavelength-band using cascaded χ((2)):χ((2)) processes, second-harmonic generation (SHG) and the following spontaneous parametric down conversion (SPDC), in a periodically poled LiNbO(3) (PPLN) ridge-waveguide device. By using a PPLN module with 600%/W of the SHG efficiency, we have achieved a coincidence-to-accidental ratio (CAR) higher than 4000 at 7.45×10(-5) of the mean number of the photon-pair per pulse. We also demonstrated that the maximum reach of the CAR was truly dark-count-limited by the single-photon detectors used here. This indicates that the fake (noise) photons were negligibly small in this system, even though the photon-pairs, the Raman noise photons, and the pump photons were in the same wavelength band. Polarization entangled photon pairs were also generated by constructing a Sagnac-loop-type interferometer which included the PPLN module and an optical phase-difference compensator to observe maximum entanglement. We achieved two-photon interference visibilities of 99.6% in the H/V basis and 98.7% in the diagonal basis. The peak coincidence count rate was approximately 50 counts per second at 10(-3) of the mean number of the photon-pair per pulse.

Optics Express•Aug 8, 2011•75 citations

Selected papers on photon statistics and coherence in nonlinear optics

Jan Peřina, Brian J. Thompson

SPIE Optical Engineering Press eBooks•Jan 1, 1991•0 citations

Optical harmonic generation enhanced due to ultrafast intensity fluctuations (Conference Presentation)

Denis A. Kopylov, Kirill Yu. Spasibko, Victor L. Krutyanskiy +3 more

The effect of the quantum properties of light on nonlinear processes has been well studied theoretically. It has been shown that the efficiency of n-photon nonlinear processes in many cases scales as the normalized n-th order correlation function. For light with high intensity correlation function, the efficiency of the n-th harmonic generation will be considerably higher than for coherent light. The experimental observation of this effect remained difficult until recently, because of the absence of bright sources with strong and fast intensity fluctuations. For the experimental demonstration of statistical effects in optical harmonic generation we use as a pump the radiation of high-gain parametric down conversion. Such light shows quantum properties (e.g. quadrature or two-mode squeezing) and has large number of photons in one mode. The normalized n-th order correlation function for this light is (2n - 1)!!, which makes it more attractive for nonlinear processes than both coherent and thermal light. For the generation of optical harmonics we used broadband parametric down conversion around frequency-degeneracy (1600 nm) produced in 1cm BBO crystal from Ti:Sapphire laser (800 nm, 1.6ps, 5kHz, 3W mean intensity). Due to spectral filtering and post-selection technique we could vary the statistics of light from coherent to super-bunched, which allowed us to demonstrate the efficiency enhancement for second-, third-, and fourth-harmonic generation. The obtained experimental results show a good agreement with the theory.

•Jun 8, 2017•0 citations
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
We report the generation of high-purity correlated photon-pairs and polarization entanglement in a 1.5 μm telecommunication wavelength-band using cascaded χ((2)):χ((2)) processes, second-harmonic generation (SHG) and the following spontaneous parametric down conversion (SPDC), in a periodically poled LiNbO(3) (PPLN) ridge-waveguide device. By using a PPLN module with 600%/W of the SHG efficiency, we have achieved a coincidence-to-accidental ratio (CAR) higher than 4000 at 7.45×10(-5) of the mean number of the photon-pair per pulse. We also demonstrated that the maximum reach of the CAR was truly dark-count-limited by the single-photon detectors used here. This indicates that the fake (noise) photons were negligibly small in this system, even though the photon-pairs, the Raman noise photons, and the pump photons were in the same wavelength band. Polarization entangled photon pairs were also generated by constructing a Sagnac-loop-type interferometer which included the PPLN module and an optical phase-difference compensator to observe maximum entanglement. We achieved two-photon interference visibilities of 99.6% in the H/V basis and 98.7% in the diagonal basis. The peak coincidence count rate was approximately 50 counts per second at 10(-3) of the mean number of the photon-pair per pulse.
The effect of the quantum properties of light on nonlinear processes has been well studied theoretically. It has been shown that the efficiency of n-photon nonlinear processes in many cases scales as the normalized n-th order correlation function. For light with high intensity correlation function, the efficiency of the n-th harmonic generation will be considerably higher than for coherent light. The experimental observation of this effect remained difficult until recently, because of the absence of bright sources with strong and fast intensity fluctuations. For the experimental demonstration of statistical effects in optical harmonic generation we use as a pump the radiation of high-gain parametric down conversion. Such light shows quantum properties (e.g. quadrature or two-mode squeezing) and has large number of photons in one mode. The normalized n-th order correlation function for this light is (2n - 1)!!, which makes it more attractive for nonlinear processes than both coherent and thermal light. For the generation of optical harmonics we used broadband parametric down conversion around frequency-degeneracy (1600 nm) produced in 1cm BBO crystal from Ti:Sapphire laser (800 nm, 1.6ps, 5kHz, 3W mean intensity). Due to spectral filtering and post-selection technique we could vary the statistics of light from coherent to super-bunched, which allowed us to demonstrate the efficiency enhancement for second-, third-, and fourth-harmonic generation. The obtained experimental results show a good agreement with the theory.