Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards

Eric A. Burt, Robert L. Tjoelker, S. Taghavi-Larigani

Published Feb 1, 2011• 0 citations
OpenAlex

Abstract

The use of the mercury ion isotope (201)Hg(+) was examined for an atomic clock. Taking advantage of the faster optical pumping time in (201)Hg(+) reduces both the state preparation and the state readout times, thereby decreasing the overall cycle time of the clock and reducing the impact of medium-term LO noise on the performance of the frequency standard. The spectral overlap between the plasma discharge lamp used for (201)Hg(+) state preparation and readout is much larger than that of the lamp used for the more conventional (199)Hg(+). There has been little study of (201)Hg(+) for clock applications (in fact, all trapped ion clock work in mercury has been with (199)Hg(+); however, recently the optical pumping time in (201)Hg(+) has been measured and found to be 0.45 second, or about three times faster than in (199)Hg(+) due largely to the better spectral overlap. This can be used to reduce the overall clock cycle time by over 2 seconds, or up to a factor of 2 improvement. The use of the (201)Hg(+) for an atomic clock is totally new. Most attempts to reduce the impact of LO noise have focused on reducing the interrogation time. In the trapped ion frequency standards built so far at JPL, the optical pumping time is already at its minimum so that no enhancement can be had by shortening it. However, by using (201)Hg(+), this is no longer the case. Furthermore, integrity monitoring, the mechanism that determines whether the clock is functioning normally, cannot happen faster than the clock cycle time. Therefore, a shorter cycle time will enable quicker detection of failure modes and recovery from them.

Related papers

Performance of Micro Mercury Trapped Ion Clock

Thai M. Hoang, Sang Kun Chung, Thanh Le +4 more

Trapped mercury ion is a promising candidate for portable and operational atomic clocks. It operates at the 40.5GHz ground state hyperfine transition of 199Hg ions. Mercury ions are confined in a linear RF trap, buffer-gas cooled, with a long ion storage lifetime in an ultra-high vacuum enclosure without an active pump. The clock transition is optically-pumped and detected with a Hg discharge lamp without need of a laser light source. This approach has proven to provide simplicity in design and implementation and robustness in operation. In this paper, we report our recently effort on developing a micro and low-power mercury trapped ion clock in the DARPA ACES program. In a 5 mm x 10 mm linear trap (0.25 cc), we have achieved the clock fractional frequency stability of .7 × 10-12τ-1/2and reached down to 7 × 10-14after 1000 seconds of averaging. We will discuss the clock performance under different conditions and implications toward a micro mercury trapped ion clock with low power and high stability.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•10 citations

Optical Frequency Standards Based on the Hg Ion

U. Tanaka, Jonas Bergquist, S. Bize +6 more

We report on work directed toward the system- atic evaluation of an optical frequency standard based on the - transition of a single, laser-cooled, trapped Hg ion, whose resonance frequency is 1.06 10 Hz. For the purpose of the evaluation, a second Hg standard has been con- structed. In the cooling-laser system built for the second standard, an injection-locking scheme has been applied to a CW Ti-sapphire laser. We also report optical frequency measurements of the clock transition performed over the past 21 months with the first standard. During this term, the variation of the clock transition frequency is found to be less than 1 10 . Index Terms—Injection-locked laser, mercury ion, optical fre- quency standard.

•Jan 1, 2003•2 citations

Fluorescence Detection and Buffer Gas Cooling of Trapped Mercury Ions in Paul Trap

Lei She, Wenming Wang, Lei Bai +4 more

Hg ions are confined in a hyperboloid ion trap. With the rf discharge 202 Hg isotope lamp, the fluorescence signal of trapped Hg ions is observed. By means of buffer gas cooling, the ionic temperature is reduced. As a result, the trapping time is increased and the signal-to-noise ratio (SNR) of the fluorescent signal is improved. The temperature of ion cloud is estimated by measuring the space charge shift.

Chinese Physics Letters•May 1, 2008•9 citations

A high-performance Hg(+) trapped ion frequency standard

John D. Prestage, Robert L. Tjoelker, G.J. Dick +1 more

A high-performance frequency standard based on (199)Hg(+) ions confined in a hybrid radio frequency (RF)/dc linear ion trap is demonstrated. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. A 160-mHz-wide atomic resonance line for the 40.5-GHz clock transition is used to steer the output of a 5-mHz crystal oscillator to obtain a stability of 2 x 10(exp -15) for 24,000-second averaging times. Measurements with a 37-mHz line width for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is better than 1 x 10(exp -15) at 10,000-second averaging times.

The Telecommunications and Data Acquisition Report•Feb 15, 1992•1 citation

Hg-201 (+) CO-Magnetometer for HG-199(+) Trapped Ion Space Atomic Clocks

Eric A. Burt, S. Taghavi-Larigani, Robert L. Tjoelker

Local magnetic field strength in a trapped ion atomic clock is measured in real time, with high accuracy and without degrading clock performance, and the measurement is used to compensate for ambient magnetic field perturbations. First and second isotopes of an element are co-located within the linear ion trap. The first isotope has a resonant microwave transition between two hyperfine energy states, and the second isotope has a resonant Zeeman transition. Optical sources emit ultraviolet light that optically pump both isotopes. A microwave radiation source simultaneously emits microwave fields resonant with the first isotope's clock transition and the second isotope's Zeeman transition, and an optical detector measures the fluorescence from optically pumping both isotopes. The second isotope's Zeeman transition provides the measure of magnetic field strength, and the measurement is used to compensate the first isotope's clock transition or to adjust the applied C-field to reduce the effects of ambient magnetic field perturbations.

•Sep 27, 2011•0 citations

DSAC and next generation high stability, long life trapped mercury ion frequency standards

Eric A. Burt, Todd Ely, Robert L. Tjoelker

Abstract The methods of trapping and cooling of atoms and ions have been transformative for atomic clocks due to the reduction, and in some cases elimination, of major systematic frequency shifts. Continuously operating atomic clocks based on trapped mercury ions have existed for decades but until recently have been restricted to terrestrial applications. The recently completed Deep Space Atomic Clock (DSAC) mission demonstrated the first trapped ion clock operation in space. Here we review DSAC as well as follow-on improvements towards the realization of high stability, long life Hg ion atomic clocks for foreseen ground and flight application.

Journal of Physics Conference Series•Nov 1, 2024•3 citations
The use of the mercury ion isotope (201)Hg(+) was examined for an atomic clock. Taking advantage of the faster optical pumping time in (201)Hg(+) reduces both the state preparation and the state readout times, thereby decreasing the overall cycle time of the clock and reducing the impact of medium-term LO noise on the performance of the frequency standard. The spectral overlap between the plasma discharge lamp used for (201)Hg(+) state preparation and readout is much larger than that of the lamp used for the more conventional (199)Hg(+). There has been little study of (201)Hg(+) for clock applications (in fact, all trapped ion clock work in mercury has been with (199)Hg(+); however, recently the optical pumping time in (201)Hg(+) has been measured and found to be 0.45 second, or about three times faster than in (199)Hg(+) due largely to the better spectral overlap. This can be used to reduce the overall clock cycle time by over 2 seconds, or up to a factor of 2 improvement. The use of the (201)Hg(+) for an atomic clock is totally new. Most attempts to reduce the impact of LO noise have focused on reducing the interrogation time. In the trapped ion frequency standards built so far at JPL, the optical pumping time is already at its minimum so that no enhancement can be had by shortening it. However, by using (201)Hg(+), this is no longer the case. Furthermore, integrity monitoring, the mechanism that determines whether the clock is functioning normally, cannot happen faster than the clock cycle time. Therefore, a shorter cycle time will enable quicker detection of failure modes and recovery from them.
Trapped mercury ion is a promising candidate for portable and operational atomic clocks. It operates at the 40.5GHz ground state hyperfine transition of 199Hg ions. Mercury ions are confined in a linear RF trap, buffer-gas cooled, with a long ion storage lifetime in an ultra-high vacuum enclosure without an active pump. The clock transition is optically-pumped and detected with a Hg discharge lamp without need of a laser light source. This approach has proven to provide simplicity in design and implementation and robustness in operation. In this paper, we report our recently effort on developing a micro and low-power mercury trapped ion clock in the DARPA ACES program. In a 5 mm x 10 mm linear trap (0.25 cc), we have achieved the clock fractional frequency stability of .7 × 10-12τ-1/2and reached down to 7 × 10-14after 1000 seconds of averaging. We will discuss the clock performance under different conditions and implications toward a micro mercury trapped ion clock with low power and high stability.
We report on work directed toward the system- atic evaluation of an optical frequency standard based on the - transition of a single, laser-cooled, trapped Hg ion, whose resonance frequency is 1.06 10 Hz. For the purpose of the evaluation, a second Hg standard has been con- structed. In the cooling-laser system built for the second standard, an injection-locking scheme has been applied to a CW Ti-sapphire laser. We also report optical frequency measurements of the clock transition performed over the past 21 months with the first standard. During this term, the variation of the clock transition frequency is found to be less than 1 10 . Index Terms—Injection-locked laser, mercury ion, optical fre- quency standard.
A high-performance frequency standard based on (199)Hg(+) ions confined in a hybrid radio frequency (RF)/dc linear ion trap is demonstrated. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. A 160-mHz-wide atomic resonance line for the 40.5-GHz clock transition is used to steer the output of a 5-mHz crystal oscillator to obtain a stability of 2 x 10(exp -15) for 24,000-second averaging times. Measurements with a 37-mHz line width for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is better than 1 x 10(exp -15) at 10,000-second averaging times.
Local magnetic field strength in a trapped ion atomic clock is measured in real time, with high accuracy and without degrading clock performance, and the measurement is used to compensate for ambient magnetic field perturbations. First and second isotopes of an element are co-located within the linear ion trap. The first isotope has a resonant microwave transition between two hyperfine energy states, and the second isotope has a resonant Zeeman transition. Optical sources emit ultraviolet light that optically pump both isotopes. A microwave radiation source simultaneously emits microwave fields resonant with the first isotope's clock transition and the second isotope's Zeeman transition, and an optical detector measures the fluorescence from optically pumping both isotopes. The second isotope's Zeeman transition provides the measure of magnetic field strength, and the measurement is used to compensate the first isotope's clock transition or to adjust the applied C-field to reduce the effects of ambient magnetic field perturbations.
Abstract The methods of trapping and cooling of atoms and ions have been transformative for atomic clocks due to the reduction, and in some cases elimination, of major systematic frequency shifts. Continuously operating atomic clocks based on trapped mercury ions have existed for decades but until recently have been restricted to terrestrial applications. The recently completed Deep Space Atomic Clock (DSAC) mission demonstrated the first trapped ion clock operation in space. Here we review DSAC as well as follow-on improvements towards the realization of high stability, long life Hg ion atomic clocks for foreseen ground and flight application.