Towards Optimization of Emission Tomography System Design using Quantum and Classical Computations

Merlin Arthur Nau

Published Jan 1, 2026• 0 citations
Publisher

Abstract

This thesis investigates inverse problems in emission tomography from three complementary perspectives: the application of quantum computing to emission tomography reconstruction, the system-level analysis of Single Photon Emission Computed Tomography (SPECT) imaging operators through null space characterization, and the use of Quantum Annealing (QA) for feature selection in medical imaging. Emission tomography enables the visualization of biological processes by detecting radiation emitted from a radiopharmaceutical administered to a patient. Reconstructing the spatial distribution of radiotracer activity from the acquired projection data constitutes a high-dimensional, ill-posed inverse problem that is further complicated by photon noise, attenuation, and incomplete angular sampling. Traditional iterative reconstruction methods, while effective, face challenges related to convergence, noise amplification, and sensitivity to system modeling assumptions. The first contribution of this thesis explores the feasibility of QA for emission tomography image reconstruction. The least-squares reconstruction problem is formulated as a Quadratic Unconstrained Binary Optimization (QUBO) model and solved using a hybrid quantum-classical solver. The method is evaluated on synthetic binary and integer-valued images of varying size, bit depth, and noise. Experiments on the D-Wave quantum annealer demonstrate that binary reconstructions are feasible for small image sizes directly on the quantum processing unit, while a hybrid solver extends the tractable image size to 32 × 32 pixels. However, scaling to higher bit depths introduces heterogeneous high-frequency noise and reveals classical bottlenecks in QUBO construction. To address the artifacts observed at increased bit depth, the second contribution introduces regularization techniques compatible with the QA formulation. Specifically, L2 and Total Variation (TV) regularization terms are incorporated into the optimization objective. These regularization strategies enforce smoothness and edge preservation in the reconstructed images and are shown to substantially improve reconstruction fidelity under the constrained discrete optimization framework, although the results remain below the quality achievable by conventional filtered backprojection. The third contribution shifts the focus from quantum-based reconstruction to a system-level analysis of SPECT imaging operators. The null space of the projection operator, which comprises all image components that are invisible to the measurement process, is computed for realistic three-dimensional (3-D) SPECT systems using an iterative Landweber-type algorithm. The analysis encompasses both conventional parallel-hole and multi-focal collimator geometries, including SMARTZOOM™ configurations used in cardiac and neurological imaging. The influence of acquisition parameters such as the number of projection views, angular sampling density, and depth-dependent point spread function modeling is systematically evaluated. Experiments on quality-control and anthropomorphic phantoms reveal that the null space is minimized by increasing angular coverage and finer sampling, and that point spread function modeling introduces characteristic ring-like structures in the null space corresponding to known reconstruction artifacts. The fourth contribution extends the use of QA to a related inverse problem: feature selection for image reconstruction. Rather than reconstructing the image directly, the objective is to identify a subset of the most informative pixels from medical images using a mutual information-based QUBO formulation. To make the problem compatible with current quantum hardware, the QUBO is spatially subsampled and sparsified to respect the limited qubit connectivity of the D-Wave Pegasus topology, and a soft linear constraint enforces the selection of a fixed number of features. The selected pixels serve as a compressed representation that is used to train a convolutional decoder for image reconstruction. Experiments on the MedMNIST benchmark demonstrate that the QA-based feature selection achieves performance comparable to classical QUBO simulations and outperforms several conventional pixel-level feature selection methods, while deep learning-based feature extractors yield higher reconstruction quality at the expense of interpretability. Overall, this thesis contributes to the understanding of how emerging quantum technologies can be applied to medical image reconstruction and related inverse problems, and provides a framework for evaluating the fundamental limitations of emission tomography systems through null space analysis.

DOI
10.25593/open-fau-3638

Related papers

Exploring the Limitations of Hybrid Adiabatic Quantum Computing for Emission Tomography Reconstruction

Merlin A. Nau, Alexander Hans Vija, W. Gohn +2 more

Our study explores the feasibility of quantum computing in emission tomography reconstruction, addressing a noisy ill-conditioned inverse problem. In current clinical practice, this is typically solved by iterative methods minimizing a L2 norm. After reviewing quantum computing principles, we propose the use of a commercially available quantum annealer and employ corresponding hybrid solvers, which combine quantum and classical computing to handle more significant problems. We demonstrate how to frame image reconstruction as a combinatorial optimization problem suited for these quantum annealers and hybrid systems. Using a toy problem, we analyze reconstructions of binary and integer-valued images with respect to their image size and compare them to conventional methods. Additionally, we test our method's performance under noise and data underdetermination. In summary, our method demonstrates competitive performance with traditional algorithms for binary images up to an image size of 32×32 on the toy problem, even under noisy and underdetermined conditions. However, scalability challenges emerge as image size and pixel bit range increase, restricting hybrid quantum computing as a practical tool for emission tomography reconstruction until significant advancements are made to address this issue.

arXiv:2212.01312•Journal of Imaging•Oct 11, 2023•22 citations

Quantum Compressed Sensing Tomographic Reconstruction Algorithm

Arim Ryou, Kiwoong Kim, Kyungtaek Jun

Computed tomography (CT) is a non-destructive technique for observing internal images and has proven highly valuable in medical diagnostics. Recent advances in quantum computing have begun to influence tomographic reconstruction techniques. The quantum tomographic reconstruction algorithm is less affected by artifacts or noise than classical algorithms by using the square function of the difference between pixels obtained by projecting CT images in quantum superposition states and pixels obtained from experimental data. In particular, by using quantum linear systems, a fast quadratic unconstrained binary optimization (QUBO) model formulation for quantum tomographic reconstruction is possible. In this paper, we formulate the QUBO model for quantum compressed sensing tomographic reconstruction, which is a linear combination of the QUBO model for quantum tomographic reconstruction and the QUBO model for total variation in quantum superposition-state CT images. In our experiments, we used sinograms obtained by using the Radon transform of Shepp-Logan images and body CT images. We evaluate the performance of the new algorithm by reconstructing CT images using a hybrid solver with the QUBO model computed from each sinogram. The new algorithm was able to obtain a solution within 5 projection images for 30 × 30 image samples and within 6 projection images for 60 × 60 image samples, reconstructing error-free CT images. We anticipate that quantum compressed sensing tomographic reconstruction algorithms could significantly reduce the total radiation dose when quantum computing performance advances.

arXiv:2505.11286•IEEE Transactions on Quantum Engineering•Jan 1, 2026•7 citations

Utilizing Quantum Annealing in Computed Tomography Image Reconstruction

Kilian Dremel, Dimitri Prjamkov, Markus Firsching +6 more

One of the primary difficulties in computed tomography (CT) is reconstructing cross-sectional images from measured projections of a physical object. There exist several classical methods for this task of generating a digital representation of the object, including filtered backprojection or simultaneous algebraic reconstruction technique. Our research aims to explore the potential of quantum computing in the field of industrial X-ray transmission tomography. Specifically, this work focuses on the application of a method similar to that proposed by Nau et al. (2023) on real CT data to demonstrate the feasibility of quadratic-unconstrained-binary-optimization-based tomographic reconstruction. Starting with simulated phantoms, results with simulated annealing as well as real annealing hardware are shown, leading to the application on measured cone-beam CT data. The results demonstrate that tomographic reconstruction using quantum annealing is feasible for both simulated and real-world applications. Yet, current limitations—involving the maximum processable size and bit depth of voxel values of the images, both correlated with the number of densely connected qubits within the annealing hardware—imply the need of future research to further improve the results. This approach, despite its early stage, has the potential to enable more sophisticated reconstructions, providing an alternative to traditional classical methods.

IEEE Transactions on Quantum Engineering•Jan 1, 2025•16 citations

Quantum-assisted tomographic image refinement with limited qubits for high-resolution imaging

Hyunju Lee, Kyungtaek Jun

We propose a quantum-assisted reconstruction framework for high-resolution tomographic imaging that reduces qubit/variable requirements by combining sinogram downsampling and region-wise iterative refinement. Previous quantum optimization–based CT reconstruction methods require solving QUBO (Quadratic Unconstrained Binary Optimization) problems over full-resolution image grids, which limits scalability under current hardware constraints. Our method addresses this by combining sinogram downscaling with region-wise iterative refinement, allowing reconstruction to begin from a reduced-resolution sinogram and image, and then to be progressively upscaled and optimized region by region. Each region is independently transformed into a compact QUBO problem and solved via a D-Wave hybrid quantum-classical solver while keeping the surrounding image fixed. The framework supports both full-view and sparse-view sinograms and is compatible with diverse acquisition geometries, including parallel-beam, fan-beam, cone-beam, synchrotron tomography, and electron tomography (ET). Adaptive region selection (including overlapping or boundary-covering subregions) enables targeted refinement of residual-error under a limited qubit/variable budget. Experimental validation on binary and integer-valued Shepp-Logan phantoms, together with an additional chest CT slice experiment, demonstrates accurate reconstructions under both dense-view and sparse-view angular sampling using reduced qubit/variable budgets. We observed that nearest-neighbor interpolation may cause edge artifacts that hinder convergence, which can be mitigated by smoother interpolation and Gaussian filtering. Sparse-view experiments indicate that the refinement pipeline can remain effective under angular undersampling in our discrete setting, suggesting potential relevance to low-dose imaging scenarios, while a dose–quality trade-off analysis is left for future work. These findings highlight the practicality of QUBO-based, quantum-assisted refinement for high-resolution tomographic reconstruction under current hardware constraints and provide a pathway for scaling as hybrid quantum optimization capabilities evolve.

arXiv:2504.20654•EPJ Quantum Technology•Jul 17, 2026•4 citations

Smarter QUBO Formulations for Quantum Annealing in Computed Tomography Image Reconstruction

Mukiri Karunakar, B. Srinivasa S. P. Kumar

Computed Tomography (CT) reconstruction can be reformulated as a Quadratic Unconstrained Binary Optimization (QUBO) problem, making it directly solvable on physical quantum processing units (QPUs). However, traditional QUBO formulations rely on a bare data-fidelity objective, ║Ax−b║2, that neglects structural image regularities and restricts reconstructions to binary variables, producing severely degraded outputs. In this paper, we present an enhanced, multi-bit regularized QUBO formulation that incorporates continuous intensity expansion alongside three image-domain constraints: (1) spatial smoothness to suppress high-frequency quantum thermal noise, (2) sparsity to refine background clarity, and (3) prior structural guidance. The proposed formulation is evaluated across diverse patient datasets (chest and abdominal CT, Shepp-Logan phantoms) at multiple resolutions (8×8 to 64×64) on both physical D-Wave Advantage QPUs and simulated-annealing samplers. Comparisons against classical Filtered Back-Projection (FBP) and Simultaneous Algebraic Reconstruction Technique (SART) demonstrate that our constrained multi-bit formulation improves Peak Signal-to-Noise Ratio (PSNR) by 5.8 dB and reduces Root Mean Square Error (RMSE) by 48.2% over unconstrained baselines. Furthermore, a systematic ablation study, hyperparameter sensitivity analysis, and hardware scalability assessment confirm the stability and resource feasibility of the proposed approach.

International Conference on Communication and Electronics Systems (ICCES)•Oct 1, 2026•0 citations

Quantum-Inspired and Optimization-Based CT Reconstruction Through Spin-Error

Hyunju Lee, Jeonghwa Lee, Yushuang Sam Yang +3 more

Quantum-optimization-based computed tomography (CT) reconstruction has demonstrated quantum supremacy in reconstruction accuracy over conventional classical methods under sparse-view and corrupted-sinogram conditions. However, scaling this approach remains challenging because larger images require increasingly many binary variables and interactions in the underlying quadratic unconstrained binary optimization (QUBO) model. Even with iterative region-of-interest (ROI) refinement, a 60 by 60 ROI with three X-ray mass attenuation coefficients requires 10,800 binary variables under our encoding. As an initial step toward larger quantum CT images, we investigate simulated annealing (SA) followed by spin-error mitigation for optimisation (SEMO), without altering the CT-QUBO objective. We evaluate three 54-view ROI reconstruction instances and nine-view reconstruction with detector-row corruption, comparing SA and SEMO with selected hybrid quantum-classical solver results. For the ROI cases, SEMO reduced the numbers of incorrectly reconstructed pixels in low-budget SA outputs from 13 to 1, 38 to 0, and 54 to 15. With 20 percent detector-row corruption, three of four selected SA and SEMO pairs achieved exact reconstruction. Applying SEMO to one hybrid-solver output reduced its ROI error from 78 to 1 pixel. Improvements were instance-dependent: in one corrupted-sinogram case, QUBO energy decreased while image-domain error increased slightly; in one ROI case, the refined image retained 15 incorrect pixels despite having lower QUBO energy than ground truth. At the evaluated problem sizes, SA and SEMO attained reconstruction accuracy comparable to or better than selected unmitigated hybrid-solver results, providing an initial solution-quality benchmark for future larger-scale, parallelized quantum CT image reconstruction.

quant-pharXiv:2610.35657•Oct 27, 2026•0 citations
This thesis investigates inverse problems in emission tomography from three complementary perspectives: the application of quantum computing to emission tomography reconstruction, the system-level analysis of Single Photon Emission Computed Tomography (SPECT) imaging operators through null space characterization, and the use of Quantum Annealing (QA) for feature selection in medical imaging. Emission tomography enables the visualization of biological processes by detecting radiation emitted from a radiopharmaceutical administered to a patient. Reconstructing the spatial distribution of radiotracer activity from the acquired projection data constitutes a high-dimensional, ill-posed inverse problem that is further complicated by photon noise, attenuation, and incomplete angular sampling. Traditional iterative reconstruction methods, while effective, face challenges related to convergence, noise amplification, and sensitivity to system modeling assumptions. The first contribution of this thesis explores the feasibility of QA for emission tomography image reconstruction. The least-squares reconstruction problem is formulated as a Quadratic Unconstrained Binary Optimization (QUBO) model and solved using a hybrid quantum-classical solver. The method is evaluated on synthetic binary and integer-valued images of varying size, bit depth, and noise. Experiments on the D-Wave quantum annealer demonstrate that binary reconstructions are feasible for small image sizes directly on the quantum processing unit, while a hybrid solver extends the tractable image size to 32 × 32 pixels. However, scaling to higher bit depths introduces heterogeneous high-frequency noise and reveals classical bottlenecks in QUBO construction. To address the artifacts observed at increased bit depth, the second contribution introduces regularization techniques compatible with the QA formulation. Specifically, L2 and Total Variation (TV) regularization terms are incorporated into the optimization objective. These regularization strategies enforce smoothness and edge preservation in the reconstructed images and are shown to substantially improve reconstruction fidelity under the constrained discrete optimization framework, although the results remain below the quality achievable by conventional filtered backprojection. The third contribution shifts the focus from quantum-based reconstruction to a system-level analysis of SPECT imaging operators. The null space of the projection operator, which comprises all image components that are invisible to the measurement process, is computed for realistic three-dimensional (3-D) SPECT systems using an iterative Landweber-type algorithm. The analysis encompasses both conventional parallel-hole and multi-focal collimator geometries, including SMARTZOOM™ configurations used in cardiac and neurological imaging. The influence of acquisition parameters such as the number of projection views, angular sampling density, and depth-dependent point spread function modeling is systematically evaluated. Experiments on quality-control and anthropomorphic phantoms reveal that the null space is minimized by increasing angular coverage and finer sampling, and that point spread function modeling introduces characteristic ring-like structures in the null space corresponding to known reconstruction artifacts. The fourth contribution extends the use of QA to a related inverse problem: feature selection for image reconstruction. Rather than reconstructing the image directly, the objective is to identify a subset of the most informative pixels from medical images using a mutual information-based QUBO formulation. To make the problem compatible with current quantum hardware, the QUBO is spatially subsampled and sparsified to respect the limited qubit connectivity of the D-Wave Pegasus topology, and a soft linear constraint enforces the selection of a fixed number of features. The selected pixels serve as a compressed representation that is used to train a convolutional decoder for image reconstruction. Experiments on the MedMNIST benchmark demonstrate that the QA-based feature selection achieves performance comparable to classical QUBO simulations and outperforms several conventional pixel-level feature selection methods, while deep learning-based feature extractors yield higher reconstruction quality at the expense of interpretability. Overall, this thesis contributes to the understanding of how emerging quantum technologies can be applied to medical image reconstruction and related inverse problems, and provides a framework for evaluating the fundamental limitations of emission tomography systems through null space analysis.
Our study explores the feasibility of quantum computing in emission tomography reconstruction, addressing a noisy ill-conditioned inverse problem. In current clinical practice, this is typically solved by iterative methods minimizing a L2 norm. After reviewing quantum computing principles, we propose the use of a commercially available quantum annealer and employ corresponding hybrid solvers, which combine quantum and classical computing to handle more significant problems. We demonstrate how to frame image reconstruction as a combinatorial optimization problem suited for these quantum annealers and hybrid systems. Using a toy problem, we analyze reconstructions of binary and integer-valued images with respect to their image size and compare them to conventional methods. Additionally, we test our method's performance under noise and data underdetermination. In summary, our method demonstrates competitive performance with traditional algorithms for binary images up to an image size of 32×32 on the toy problem, even under noisy and underdetermined conditions. However, scalability challenges emerge as image size and pixel bit range increase, restricting hybrid quantum computing as a practical tool for emission tomography reconstruction until significant advancements are made to address this issue.
Computed tomography (CT) is a non-destructive technique for observing internal images and has proven highly valuable in medical diagnostics. Recent advances in quantum computing have begun to influence tomographic reconstruction techniques. The quantum tomographic reconstruction algorithm is less affected by artifacts or noise than classical algorithms by using the square function of the difference between pixels obtained by projecting CT images in quantum superposition states and pixels obtained from experimental data. In particular, by using quantum linear systems, a fast quadratic unconstrained binary optimization (QUBO) model formulation for quantum tomographic reconstruction is possible. In this paper, we formulate the QUBO model for quantum compressed sensing tomographic reconstruction, which is a linear combination of the QUBO model for quantum tomographic reconstruction and the QUBO model for total variation in quantum superposition-state CT images. In our experiments, we used sinograms obtained by using the Radon transform of Shepp-Logan images and body CT images. We evaluate the performance of the new algorithm by reconstructing CT images using a hybrid solver with the QUBO model computed from each sinogram. The new algorithm was able to obtain a solution within 5 projection images for 30 × 30 image samples and within 6 projection images for 60 × 60 image samples, reconstructing error-free CT images. We anticipate that quantum compressed sensing tomographic reconstruction algorithms could significantly reduce the total radiation dose when quantum computing performance advances.
One of the primary difficulties in computed tomography (CT) is reconstructing cross-sectional images from measured projections of a physical object. There exist several classical methods for this task of generating a digital representation of the object, including filtered backprojection or simultaneous algebraic reconstruction technique. Our research aims to explore the potential of quantum computing in the field of industrial X-ray transmission tomography. Specifically, this work focuses on the application of a method similar to that proposed by Nau et al. (2023) on real CT data to demonstrate the feasibility of quadratic-unconstrained-binary-optimization-based tomographic reconstruction. Starting with simulated phantoms, results with simulated annealing as well as real annealing hardware are shown, leading to the application on measured cone-beam CT data. The results demonstrate that tomographic reconstruction using quantum annealing is feasible for both simulated and real-world applications. Yet, current limitations—involving the maximum processable size and bit depth of voxel values of the images, both correlated with the number of densely connected qubits within the annealing hardware—imply the need of future research to further improve the results. This approach, despite its early stage, has the potential to enable more sophisticated reconstructions, providing an alternative to traditional classical methods.
We propose a quantum-assisted reconstruction framework for high-resolution tomographic imaging that reduces qubit/variable requirements by combining sinogram downsampling and region-wise iterative refinement. Previous quantum optimization–based CT reconstruction methods require solving QUBO (Quadratic Unconstrained Binary Optimization) problems over full-resolution image grids, which limits scalability under current hardware constraints. Our method addresses this by combining sinogram downscaling with region-wise iterative refinement, allowing reconstruction to begin from a reduced-resolution sinogram and image, and then to be progressively upscaled and optimized region by region. Each region is independently transformed into a compact QUBO problem and solved via a D-Wave hybrid quantum-classical solver while keeping the surrounding image fixed. The framework supports both full-view and sparse-view sinograms and is compatible with diverse acquisition geometries, including parallel-beam, fan-beam, cone-beam, synchrotron tomography, and electron tomography (ET). Adaptive region selection (including overlapping or boundary-covering subregions) enables targeted refinement of residual-error under a limited qubit/variable budget. Experimental validation on binary and integer-valued Shepp-Logan phantoms, together with an additional chest CT slice experiment, demonstrates accurate reconstructions under both dense-view and sparse-view angular sampling using reduced qubit/variable budgets. We observed that nearest-neighbor interpolation may cause edge artifacts that hinder convergence, which can be mitigated by smoother interpolation and Gaussian filtering. Sparse-view experiments indicate that the refinement pipeline can remain effective under angular undersampling in our discrete setting, suggesting potential relevance to low-dose imaging scenarios, while a dose–quality trade-off analysis is left for future work. These findings highlight the practicality of QUBO-based, quantum-assisted refinement for high-resolution tomographic reconstruction under current hardware constraints and provide a pathway for scaling as hybrid quantum optimization capabilities evolve.
Computed Tomography (CT) reconstruction can be reformulated as a Quadratic Unconstrained Binary Optimization (QUBO) problem, making it directly solvable on physical quantum processing units (QPUs). However, traditional QUBO formulations rely on a bare data-fidelity objective, ║Ax−b║2, that neglects structural image regularities and restricts reconstructions to binary variables, producing severely degraded outputs. In this paper, we present an enhanced, multi-bit regularized QUBO formulation that incorporates continuous intensity expansion alongside three image-domain constraints: (1) spatial smoothness to suppress high-frequency quantum thermal noise, (2) sparsity to refine background clarity, and (3) prior structural guidance. The proposed formulation is evaluated across diverse patient datasets (chest and abdominal CT, Shepp-Logan phantoms) at multiple resolutions (8×8 to 64×64) on both physical D-Wave Advantage QPUs and simulated-annealing samplers. Comparisons against classical Filtered Back-Projection (FBP) and Simultaneous Algebraic Reconstruction Technique (SART) demonstrate that our constrained multi-bit formulation improves Peak Signal-to-Noise Ratio (PSNR) by 5.8 dB and reduces Root Mean Square Error (RMSE) by 48.2% over unconstrained baselines. Furthermore, a systematic ablation study, hyperparameter sensitivity analysis, and hardware scalability assessment confirm the stability and resource feasibility of the proposed approach.
Quantum-optimization-based computed tomography (CT) reconstruction has demonstrated quantum supremacy in reconstruction accuracy over conventional classical methods under sparse-view and corrupted-sinogram conditions. However, scaling this approach remains challenging because larger images require increasingly many binary variables and interactions in the underlying quadratic unconstrained binary optimization (QUBO) model. Even with iterative region-of-interest (ROI) refinement, a 60 by 60 ROI with three X-ray mass attenuation coefficients requires 10,800 binary variables under our encoding. As an initial step toward larger quantum CT images, we investigate simulated annealing (SA) followed by spin-error mitigation for optimisation (SEMO), without altering the CT-QUBO objective. We evaluate three 54-view ROI reconstruction instances and nine-view reconstruction with detector-row corruption, comparing SA and SEMO with selected hybrid quantum-classical solver results. For the ROI cases, SEMO reduced the numbers of incorrectly reconstructed pixels in low-budget SA outputs from 13 to 1, 38 to 0, and 54 to 15. With 20 percent detector-row corruption, three of four selected SA and SEMO pairs achieved exact reconstruction. Applying SEMO to one hybrid-solver output reduced its ROI error from 78 to 1 pixel. Improvements were instance-dependent: in one corrupted-sinogram case, QUBO energy decreased while image-domain error increased slightly; in one ROI case, the refined image retained 15 incorrect pixels despite having lower QUBO energy than ground truth. At the evaluated problem sizes, SA and SEMO attained reconstruction accuracy comparable to or better than selected unmitigated hybrid-solver results, providing an initial solution-quality benchmark for future larger-scale, parallelized quantum CT image reconstruction.