International Conference on Communication and Electronics Systems (ICCES)

Smarter QUBO Formulations for Quantum Annealing in Computed Tomography Image Reconstruction

Mukiri Karunakar, B. Srinivasa S. P. Kumar

Published Oct 1, 2026• 0 citations
Publisher

Abstract

Computed Tomography (CT) reconstruction can be reformulated as a Quadratic Unconstrained Binary Optimization (QUBO) problem, making it directly solvable on physical quantum processing units (QPUs). However, traditional QUBO formulations rely on a bare data-fidelity objective, ║Ax−b║2, that neglects structural image regularities and restricts reconstructions to binary variables, producing severely degraded outputs. In this paper, we present an enhanced, multi-bit regularized QUBO formulation that incorporates continuous intensity expansion alongside three image-domain constraints: (1) spatial smoothness to suppress high-frequency quantum thermal noise, (2) sparsity to refine background clarity, and (3) prior structural guidance. The proposed formulation is evaluated across diverse patient datasets (chest and abdominal CT, Shepp-Logan phantoms) at multiple resolutions (8×8 to 64×64) on both physical D-Wave Advantage QPUs and simulated-annealing samplers. Comparisons against classical Filtered Back-Projection (FBP) and Simultaneous Algebraic Reconstruction Technique (SART) demonstrate that our constrained multi-bit formulation improves Peak Signal-to-Noise Ratio (PSNR) by 5.8 dB and reduces Root Mean Square Error (RMSE) by 48.2% over unconstrained baselines. Furthermore, a systematic ablation study, hyperparameter sensitivity analysis, and hardware scalability assessment confirm the stability and resource feasibility of the proposed approach.

DOI
10.1109/icces70397.2026.11762694

Related papers

Utilizing Quantum Annealing in Computed Tomography Image Reconstruction

Kilian Dremel, Dimitri Prjamkov, Markus Firsching +6 more

One of the primary difficulties in computed tomography (CT) is reconstructing cross-sectional images from measured projections of a physical object. There exist several classical methods for this task of generating a digital representation of the object, including filtered backprojection or simultaneous algebraic reconstruction technique. Our research aims to explore the potential of quantum computing in the field of industrial X-ray transmission tomography. Specifically, this work focuses on the application of a method similar to that proposed by Nau et al. (2023) on real CT data to demonstrate the feasibility of quadratic-unconstrained-binary-optimization-based tomographic reconstruction. Starting with simulated phantoms, results with simulated annealing as well as real annealing hardware are shown, leading to the application on measured cone-beam CT data. The results demonstrate that tomographic reconstruction using quantum annealing is feasible for both simulated and real-world applications. Yet, current limitations—involving the maximum processable size and bit depth of voxel values of the images, both correlated with the number of densely connected qubits within the annealing hardware—imply the need of future research to further improve the results. This approach, despite its early stage, has the potential to enable more sophisticated reconstructions, providing an alternative to traditional classical methods.

IEEE Transactions on Quantum Engineering•Jan 1, 2025•16 citations

Quantum computing for the optimization of CT image reconstruction

Hyunju Lee, Youngpyo Ryu, Jennifer Kim +1 more

Computed tomography (CT) is an important diagnostic technique used to analyze the inner structure of the human body. Various reconstruction methods of CT images have been proposed and utilized for a long time. The existing optimization methods for CT reconstruction images, however, usually suffer from substantial computational complexities. To circumvent this difficulty, a quadratic unconstrained binary optimization (QUBO) model for fast and accurate reconstruction of CT images was recently developed. In this paper, we apply the QUBO model to the 15-by-15 sized Shepp-Logan phantom image sample of the largest computable image in the D-Wave Advantage System. Herein, we reconstructed the CT image of the QUBO model in the D-Wave system using a QPU solver and a hybrid solver. Here are our results.

International Conference on Information and Communication Technology Convergence (ICTC)•Oct 19, 2022•1 citation

Quantum CT via Dynamic Interval Encoding and Prior-Balanced QUBO Reconstruction

A F Wang, Yikuang Yuluo, Yujie Liu +7 more

Quadratic unconstrained binary optimization (QUBO)-based quantum computed tomography (CT) casts reconstruction as a binary quadratic problem for quantum annealing and hybrid quantum--classical solvers. For grayscale CT, however, image encoding is constrained by the binary-variable budget: fixed global bit-plane encodings increase QUBO size and coupling complexity as gray-level precision improves, whereas low-bit encodings introduce quantization error. We propose a QUBO-based grayscale CT reconstruction framework that combines dynamic interval encoding with prior-balanced optimization. Each refinement round encodes active pixels only within local gray-level intervals around the current estimate, and a boundary-hit-guided update rule adaptively switches between search expansion and local refinement. To improve optimization stability, the method balances projection-domain data consistency and an edge-preserving quadratic prior before forming the final QUBO. Sparse-view and limited-angle fan-beam CT experiments show that the proposed method recovers structures and gray-level distributions more faithfully than the evaluated analytic, iterative, variational, and representation-based baselines. Expressivity analysis and ablation studies further indicate that the improvement mainly arises from effective gray-level representation through dynamic local encoding and more stable data-fidelity--prior coupling. Experiments on the D-Wave hybrid binary quadratic model (BQM) solver further demonstrate that the formulation is executable on a hardware-backed hybrid quantum--classical backend.

arXiv:2606.24561•Jun 23, 2026•0 citations

Quantum Compressed Sensing Tomographic Reconstruction Algorithm

Arim Ryou, Kiwoong Kim, Kyungtaek Jun

Computed tomography (CT) is a non-destructive technique for observing internal images and has proven highly valuable in medical diagnostics. Recent advances in quantum computing have begun to influence tomographic reconstruction techniques. The quantum tomographic reconstruction algorithm is less affected by artifacts or noise than classical algorithms by using the square function of the difference between pixels obtained by projecting CT images in quantum superposition states and pixels obtained from experimental data. In particular, by using quantum linear systems, a fast quadratic unconstrained binary optimization (QUBO) model formulation for quantum tomographic reconstruction is possible. In this paper, we formulate the QUBO model for quantum compressed sensing tomographic reconstruction, which is a linear combination of the QUBO model for quantum tomographic reconstruction and the QUBO model for total variation in quantum superposition-state CT images. In our experiments, we used sinograms obtained by using the Radon transform of Shepp-Logan images and body CT images. We evaluate the performance of the new algorithm by reconstructing CT images using a hybrid solver with the QUBO model computed from each sinogram. The new algorithm was able to obtain a solution within 5 projection images for 30 × 30 image samples and within 6 projection images for 60 × 60 image samples, reconstructing error-free CT images. We anticipate that quantum compressed sensing tomographic reconstruction algorithms could significantly reduce the total radiation dose when quantum computing performance advances.

arXiv:2505.11286•IEEE Transactions on Quantum Engineering•Jan 1, 2026•7 citations

Quantum annealing-based computed tomography using variational approach for a real-number image reconstruction

Akihiro Haga

Objective . Despite recent advancements in quantum computing, the limited number of available qubits has hindered progress in CT reconstruction. This study investigates the feasibility of utilizing quantum annealing-based computed tomography (QACT) with current quantum bit levels. Approach . The QACT algorithm aims to precisely solve quadratic unconstrained binary optimization problems. Furthermore, a novel approach is proposed to reconstruct images by approximating real numbers using the variational method. This approach allows for accurate CT image reconstruction using a small number of qubits. The study examines the impact of projection data quantity and noise on various image sizes ranging from 4 × 4 to 24 × 24 pixels. The reconstructed results are compared against conventional reconstruction algorithms, namely maximum likelihood expectation maximization (MLEM) and filtered back projection (FBP). Main result . By employing the variational approach and utilizing two qubits for each pixel of the image, accurate reconstruction was achieved with an adequate number of projections. Under conditions of abundant projections and lower noise levels, the image quality in QACT algorithm outperformed that of MLEM and FBP algorithms. However, in situations with limited projection data and in the presence of noise, the image quality in QACT was inferior to that in MLEM. Significance . This study developed the QACT reconstruction algorithm using the variational approach for real-number reconstruction. Remarkably, only 2 qubits were required for each pixel representation, demonstrating their sufficiency for accurate reconstruction.

arXiv:2306.02214•Physics in Medicine and Biology•Feb 8, 2024•12 citations

Quantum-Inspired and Optimization-Based CT Reconstruction Through Spin-Error

Hyunju Lee, Jeonghwa Lee, Yushuang Sam Yang +3 more

Quantum-optimization-based computed tomography (CT) reconstruction has demonstrated quantum supremacy in reconstruction accuracy over conventional classical methods under sparse-view and corrupted-sinogram conditions. However, scaling this approach remains challenging because larger images require increasingly many binary variables and interactions in the underlying quadratic unconstrained binary optimization (QUBO) model. Even with iterative region-of-interest (ROI) refinement, a 60 by 60 ROI with three X-ray mass attenuation coefficients requires 10,800 binary variables under our encoding. As an initial step toward larger quantum CT images, we investigate simulated annealing (SA) followed by spin-error mitigation for optimisation (SEMO), without altering the CT-QUBO objective. We evaluate three 54-view ROI reconstruction instances and nine-view reconstruction with detector-row corruption, comparing SA and SEMO with selected hybrid quantum-classical solver results. For the ROI cases, SEMO reduced the numbers of incorrectly reconstructed pixels in low-budget SA outputs from 13 to 1, 38 to 0, and 54 to 15. With 20 percent detector-row corruption, three of four selected SA and SEMO pairs achieved exact reconstruction. Applying SEMO to one hybrid-solver output reduced its ROI error from 78 to 1 pixel. Improvements were instance-dependent: in one corrupted-sinogram case, QUBO energy decreased while image-domain error increased slightly; in one ROI case, the refined image retained 15 incorrect pixels despite having lower QUBO energy than ground truth. At the evaluated problem sizes, SA and SEMO attained reconstruction accuracy comparable to or better than selected unmitigated hybrid-solver results, providing an initial solution-quality benchmark for future larger-scale, parallelized quantum CT image reconstruction.

quant-pharXiv:2610.35657•Oct 27, 2026•0 citations
Computed Tomography (CT) reconstruction can be reformulated as a Quadratic Unconstrained Binary Optimization (QUBO) problem, making it directly solvable on physical quantum processing units (QPUs). However, traditional QUBO formulations rely on a bare data-fidelity objective, ║Ax−b║2, that neglects structural image regularities and restricts reconstructions to binary variables, producing severely degraded outputs. In this paper, we present an enhanced, multi-bit regularized QUBO formulation that incorporates continuous intensity expansion alongside three image-domain constraints: (1) spatial smoothness to suppress high-frequency quantum thermal noise, (2) sparsity to refine background clarity, and (3) prior structural guidance. The proposed formulation is evaluated across diverse patient datasets (chest and abdominal CT, Shepp-Logan phantoms) at multiple resolutions (8×8 to 64×64) on both physical D-Wave Advantage QPUs and simulated-annealing samplers. Comparisons against classical Filtered Back-Projection (FBP) and Simultaneous Algebraic Reconstruction Technique (SART) demonstrate that our constrained multi-bit formulation improves Peak Signal-to-Noise Ratio (PSNR) by 5.8 dB and reduces Root Mean Square Error (RMSE) by 48.2% over unconstrained baselines. Furthermore, a systematic ablation study, hyperparameter sensitivity analysis, and hardware scalability assessment confirm the stability and resource feasibility of the proposed approach.
One of the primary difficulties in computed tomography (CT) is reconstructing cross-sectional images from measured projections of a physical object. There exist several classical methods for this task of generating a digital representation of the object, including filtered backprojection or simultaneous algebraic reconstruction technique. Our research aims to explore the potential of quantum computing in the field of industrial X-ray transmission tomography. Specifically, this work focuses on the application of a method similar to that proposed by Nau et al. (2023) on real CT data to demonstrate the feasibility of quadratic-unconstrained-binary-optimization-based tomographic reconstruction. Starting with simulated phantoms, results with simulated annealing as well as real annealing hardware are shown, leading to the application on measured cone-beam CT data. The results demonstrate that tomographic reconstruction using quantum annealing is feasible for both simulated and real-world applications. Yet, current limitations—involving the maximum processable size and bit depth of voxel values of the images, both correlated with the number of densely connected qubits within the annealing hardware—imply the need of future research to further improve the results. This approach, despite its early stage, has the potential to enable more sophisticated reconstructions, providing an alternative to traditional classical methods.
Computed tomography (CT) is an important diagnostic technique used to analyze the inner structure of the human body. Various reconstruction methods of CT images have been proposed and utilized for a long time. The existing optimization methods for CT reconstruction images, however, usually suffer from substantial computational complexities. To circumvent this difficulty, a quadratic unconstrained binary optimization (QUBO) model for fast and accurate reconstruction of CT images was recently developed. In this paper, we apply the QUBO model to the 15-by-15 sized Shepp-Logan phantom image sample of the largest computable image in the D-Wave Advantage System. Herein, we reconstructed the CT image of the QUBO model in the D-Wave system using a QPU solver and a hybrid solver. Here are our results.
Quadratic unconstrained binary optimization (QUBO)-based quantum computed tomography (CT) casts reconstruction as a binary quadratic problem for quantum annealing and hybrid quantum--classical solvers. For grayscale CT, however, image encoding is constrained by the binary-variable budget: fixed global bit-plane encodings increase QUBO size and coupling complexity as gray-level precision improves, whereas low-bit encodings introduce quantization error. We propose a QUBO-based grayscale CT reconstruction framework that combines dynamic interval encoding with prior-balanced optimization. Each refinement round encodes active pixels only within local gray-level intervals around the current estimate, and a boundary-hit-guided update rule adaptively switches between search expansion and local refinement. To improve optimization stability, the method balances projection-domain data consistency and an edge-preserving quadratic prior before forming the final QUBO. Sparse-view and limited-angle fan-beam CT experiments show that the proposed method recovers structures and gray-level distributions more faithfully than the evaluated analytic, iterative, variational, and representation-based baselines. Expressivity analysis and ablation studies further indicate that the improvement mainly arises from effective gray-level representation through dynamic local encoding and more stable data-fidelity--prior coupling. Experiments on the D-Wave hybrid binary quadratic model (BQM) solver further demonstrate that the formulation is executable on a hardware-backed hybrid quantum--classical backend.
Computed tomography (CT) is a non-destructive technique for observing internal images and has proven highly valuable in medical diagnostics. Recent advances in quantum computing have begun to influence tomographic reconstruction techniques. The quantum tomographic reconstruction algorithm is less affected by artifacts or noise than classical algorithms by using the square function of the difference between pixels obtained by projecting CT images in quantum superposition states and pixels obtained from experimental data. In particular, by using quantum linear systems, a fast quadratic unconstrained binary optimization (QUBO) model formulation for quantum tomographic reconstruction is possible. In this paper, we formulate the QUBO model for quantum compressed sensing tomographic reconstruction, which is a linear combination of the QUBO model for quantum tomographic reconstruction and the QUBO model for total variation in quantum superposition-state CT images. In our experiments, we used sinograms obtained by using the Radon transform of Shepp-Logan images and body CT images. We evaluate the performance of the new algorithm by reconstructing CT images using a hybrid solver with the QUBO model computed from each sinogram. The new algorithm was able to obtain a solution within 5 projection images for 30 × 30 image samples and within 6 projection images for 60 × 60 image samples, reconstructing error-free CT images. We anticipate that quantum compressed sensing tomographic reconstruction algorithms could significantly reduce the total radiation dose when quantum computing performance advances.
Objective . Despite recent advancements in quantum computing, the limited number of available qubits has hindered progress in CT reconstruction. This study investigates the feasibility of utilizing quantum annealing-based computed tomography (QACT) with current quantum bit levels. Approach . The QACT algorithm aims to precisely solve quadratic unconstrained binary optimization problems. Furthermore, a novel approach is proposed to reconstruct images by approximating real numbers using the variational method. This approach allows for accurate CT image reconstruction using a small number of qubits. The study examines the impact of projection data quantity and noise on various image sizes ranging from 4 × 4 to 24 × 24 pixels. The reconstructed results are compared against conventional reconstruction algorithms, namely maximum likelihood expectation maximization (MLEM) and filtered back projection (FBP). Main result . By employing the variational approach and utilizing two qubits for each pixel of the image, accurate reconstruction was achieved with an adequate number of projections. Under conditions of abundant projections and lower noise levels, the image quality in QACT algorithm outperformed that of MLEM and FBP algorithms. However, in situations with limited projection data and in the presence of noise, the image quality in QACT was inferior to that in MLEM. Significance . This study developed the QACT reconstruction algorithm using the variational approach for real-number reconstruction. Remarkably, only 2 qubits were required for each pixel representation, demonstrating their sufficiency for accurate reconstruction.
Quantum-optimization-based computed tomography (CT) reconstruction has demonstrated quantum supremacy in reconstruction accuracy over conventional classical methods under sparse-view and corrupted-sinogram conditions. However, scaling this approach remains challenging because larger images require increasingly many binary variables and interactions in the underlying quadratic unconstrained binary optimization (QUBO) model. Even with iterative region-of-interest (ROI) refinement, a 60 by 60 ROI with three X-ray mass attenuation coefficients requires 10,800 binary variables under our encoding. As an initial step toward larger quantum CT images, we investigate simulated annealing (SA) followed by spin-error mitigation for optimisation (SEMO), without altering the CT-QUBO objective. We evaluate three 54-view ROI reconstruction instances and nine-view reconstruction with detector-row corruption, comparing SA and SEMO with selected hybrid quantum-classical solver results. For the ROI cases, SEMO reduced the numbers of incorrectly reconstructed pixels in low-budget SA outputs from 13 to 1, 38 to 0, and 54 to 15. With 20 percent detector-row corruption, three of four selected SA and SEMO pairs achieved exact reconstruction. Applying SEMO to one hybrid-solver output reduced its ROI error from 78 to 1 pixel. Improvements were instance-dependent: in one corrupted-sinogram case, QUBO energy decreased while image-domain error increased slightly; in one ROI case, the refined image retained 15 incorrect pixels despite having lower QUBO energy than ground truth. At the evaluated problem sizes, SA and SEMO attained reconstruction accuracy comparable to or better than selected unmitigated hybrid-solver results, providing an initial solution-quality benchmark for future larger-scale, parallelized quantum CT image reconstruction.