Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)

Optical and Magnetic Pulse Modulation for Free-Induction-Decay Atomic Magnetometer

Jinghong Xu, Haowen Tian, Wenjing Tian, Jiali Liu, Liwei Jiang

Published Aug 1, 2026• 0 citations
Publisher

Abstract

We perform a systematic study of optical and magnetic modulation method for free-induction-decay atomic magnetometers, demonstrating the signal responses to relative magnetic field orientations and the dead zones of the magnetometers with different configurations.
DOI
10.1109/cleo-pr70283.2026.11765773

Related papers

Dead-zone-free orientation-based pulsed atomic magnetometer

Jinghong Xu, Liwei Jiang, Yuntian Zou +6 more

The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.

Physical Review Research•Apr 6, 2026•1 citation

Dead-zone suppression method of NMOR atomic magnetometers based on alignment and orientation polarization

Mengnan Tian, Liwei Jiang, Xin Hui Zhao +4 more

Sensors and Actuators A Physical•Sep 2, 2024•10 citations

“Fictitious” Magnetic Fields for Atomic Magnetometers

Martin Rodriguez-Vega

Researchers have achieved dual-axis magnetic-field detection using an atomic magnetometer architecture with only optical instruments.

Physics•Jan 16, 2024•0 citations

Measurement and suppression of tensor light shift for nonlinear magneto-optical rotating atomic magnetometers

Mengnan Tian, Liwei Jiang, Yanchao Chai +5 more

Sensors and Actuators A Physical•Apr 21, 2025•2 citations

Dead‐Zone‐Free NMOR Atomic Magnetometer Based on Excitation of Dual‐Axis Magnetic Pulse

Liwei Jiang, Changhao Zhang, Xin Hui Zhao +3 more

Abstract Nonlinear magneto‐optical rotation (NMOR) atomic magnetometer has extreme precision and sensitivity. However, atomic magnetometer suffers from the problem of dead zone that the sensitive signal decays to zero if the magnetic field is along some specific directions relative to the sensor. In this paper, a new scheme based on excitation of dual‐axis magnetic pulse is presented to eliminate the dead zone of NMOR atomic magnetometer. The magnetic field measurement is based on the mode of free induction decay (FID), which allows pumping and detecting stages to be separated without interference from magnetic pulse. The dead zone model is developed for NMOR atomic magnetometer from the mechanism of interaction between optical field and polarized atoms. To eliminate the dead zone of NMOR atomic magnetometer, the response model with dual‐axis magnetic pulse excitation is established by using the density matrix theory for bias magnetic field in arbitrary direction. Then the proposed method of suppressing the dead zone is examined in the experiment, which is in agreement with the developed model. The results show that the method can effectively eliminate the dead zone of NMOR atomic magnetometer, which is of great significance to measurement of magnetic field in complex magnetic environment with variable direction.

Advanced Quantum Technologies•Jan 17, 2025•9 citations

High Sensitivity Atomic Magnetometers and Their Applications

Michael V. Romalis

I will review recent progress in optical magnetometry techniques using spin-polarized alkali-metal atoms and discuss their applications for detection of nuclear magnetic resonance, biological magnetic fields, rotation sending, and fundamental physics tests.

Frontiers in Optics•Jan 1, 2007•0 citations
The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.
Abstract Nonlinear magneto‐optical rotation (NMOR) atomic magnetometer has extreme precision and sensitivity. However, atomic magnetometer suffers from the problem of dead zone that the sensitive signal decays to zero if the magnetic field is along some specific directions relative to the sensor. In this paper, a new scheme based on excitation of dual‐axis magnetic pulse is presented to eliminate the dead zone of NMOR atomic magnetometer. The magnetic field measurement is based on the mode of free induction decay (FID), which allows pumping and detecting stages to be separated without interference from magnetic pulse. The dead zone model is developed for NMOR atomic magnetometer from the mechanism of interaction between optical field and polarized atoms. To eliminate the dead zone of NMOR atomic magnetometer, the response model with dual‐axis magnetic pulse excitation is established by using the density matrix theory for bias magnetic field in arbitrary direction. Then the proposed method of suppressing the dead zone is examined in the experiment, which is in agreement with the developed model. The results show that the method can effectively eliminate the dead zone of NMOR atomic magnetometer, which is of great significance to measurement of magnetic field in complex magnetic environment with variable direction.