Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Granular Localisation Length and the Minimum Length: Bounds on Spontaneous Collapse Width from Interferometry

William Alexander Aldred

Published Nov 11, 2026• 0 citations
Publisher

Abstract

This paper examines whether a fundamental minimum length constrains the correlation length used in spontaneous collapse models. The Planck length is 1.616e-35 metres. For a superposition of one million nucleons separated by one hundred nanometres, the computed collapse-induced decoherence rate varies from 1.000e-10 per second when the correlation length is ten nanometres to 2.500e-15 per second when it is ten micrometres, with 2.212e-11 per second at the conventional one hundred nanometres. Every correlation length under laboratory discussion exceeds the Planck length by more than twenty orders of magnitude, so the minimum length imposes no practical restriction on the parameter; interferometry, not geometry, is what narrows the allowed interval. The study is simulated and computed from stated assumptions; it is not a measurement.

DOI
10.5281/zenodo.24145255

Related papers

Spontaneous Radiation Bounds on Collapse Models: Recomputed Emission Rates for Germanium Detectors

William Alexander Aldred

This paper recomputes relative spontaneous-radiation rates for collapse models under the scaling with collapse rate and correlation length used in detector analyses, normalised to a stated reference point. At the conventional parameters the normalised rate is 1.00e-03 in the units adopted here; raising the collapse rate to 1e-10 per second raises the emission to 1.000e+03, while widening the correlation length to one micrometre lowers it to 1.000e-05. The inverse-square dependence on correlation length means radiation searches and interferometric searches probe complementary directions in parameter space, and neither alone closes the plane. All rates here are relative to the stated normalisation; absolute detector limits require the full spectral calculation. The study is simulated and computed from stated assumptions; it is not a measurement.

•Nov 11, 2026•0 citations

Continuous Spontaneous Localisation Rates Implied by a Maximum Density: A Computed Bound and Laboratory Comparison

William Alexander Aldred

This paper computes what a maximum mass density implies for the collapse rate in continuous spontaneous localisation models and compares the outcome with laboratory limits. The density ceiling adopted here is 9.717e+57 kilograms per cubic metre on the neutron branch. Translating the ceiling into an energy budget over a Hubble time gives a formal upper value for the collapse rate of 6.753e+57 per second, many orders of magnitude above both the conventional value of 1.00e-16 per second and the stronger value of 1.00e-08 per second sometimes advocated on phenomenological grounds. The associated heating at the conventional rate is only 2.973e-17 watts per kilogram. The ceiling therefore does not restrict the collapse rate within any range currently discussed; the binding restrictions remain the laboratory limits from spontaneous radiation and force-noise measurements, which are tighter by an enormous margin. The study is simulated and computed from stated assumptions; it is not a measurement.

•Nov 11, 2026•0 citations

Correlated random walks caused by dynamical wavefunction collapse

Daniel Bedingham, Hendrik Ulbricht

Wavefunction collapse models modify Schrödinger's equation so that it describes the collapse of a superposition of macroscopically distinguishable states as a dynamical process. This provides a basis for the resolution of the quantum measurement problem. An additional generic consequence of the collapse mechanism is that it causes particles to exhibit a tiny random diffusive motion. Here it is shown that for the continuous spontaneous localization (CSL) model—one of the most well developed collapse models—the diffusions of two sufficiently nearby particles are positively correlated. An experimental test of this effect is proposed in which random displacements of pairs of free nanoparticles are measured after they have been simultaneously released from nearby traps. The experiment must be carried out at sufficiently low temperature and pressure in order for the collapse effects to dominate over the ambient environmental noise. It is argued that these constraints can be satisfied by current technologies for a large region of the viable parameter space of the CSL model. The effect disappears as the separation between particles exceeds the CSL length scale. The test therefore provides a means of bounding this length scale.

arXiv:1411.6921•Scientific Reports•Aug 25, 2015•2 citations

Collapse-Model Force Noise in Gravitational-Wave Interferometers: Computed Spectral Density Against Detector Noise

William Alexander Aldred

This paper estimates, under an explicitly stated normalisation, the displacement noise that collapse-model force fluctuations would produce in a gravitational-wave interferometer and compares it with representative detector sensitivity. The displacement amplitude spectral density is 6.333e-29 metres per root hertz at the conventional collapse rate and 6.333e-25 metres per root hertz at a rate of 1e-08 per second, against a representative detector level of 1.00e-19 metres per root hertz near one hundred hertz. On this normalisation the conventional rate lies below detector noise and the stronger rate lies above it, which is why interferometer data already inform the upper part of the parameter range. The normalisation is the main uncertainty and is stated openly. The study is simulated and computed from stated assumptions; it is not a measurement.

•Nov 11, 2026•0 citations

Microscopic Origins of Collapse Models: Decoherence from Graviton Bremsstrahlung

Moslem Zarei

Some collapse models proposed that gravitational effects cause the instability of mass distribution superpositions, leading to wave function collapse. In this paper, we utilize the quantum Boltzmann equation (QBE) to analyze the behavior of a fermion in a spatial superposition under graviton emission. We introduce a quantitative measure that links the stability of the superposition to the spatial separation, particle mass, and gravitational coupling. By examining the collision term in the QBE, we derive the decoherence rate and show how it depends on these parameters. Our results provide a detailed framework for understanding gravity induced decoherence, bridging the gap between quantum field theory and collapse models. We also discuss the implications of these findings for experimental tests of gravitationally induced wave function collapse and the broader class of collapse models known as dissipative continuous spontaneous localization (CSL) model.

quant-pharXiv:2605.12955•May 14, 2026•0 citations

Quantum-Gravity Tabletop Probes Constrain Planck-Scale Collapse Models — E8 Intelligence Research

Andrew Stewart Caldin

FINDING: Tabletop quantum-gravity tests probe Planck-scale discreteness via matter-wave interferometry and optomechanical superposition, not yet yielding a confirmed equation but constraining collapse models and graviton signatures. | MATH: Planck length \(l_P = \sqrt{\hbar G/c^3} \approx 1.616\times10^{-35}\,\text{m}\); Planck mass \(m_P = \sqrt{\hbar c/G} \approx 2.176\times10^{-8}\,\text{kg}\); decoherence rate for gravitationally-induced collapse (Penrose–Diosi): \(\Gamma \sim \Delta E_G/\hbar\), where \(\Delta E_G = \frac{G}{2}\int\!\!\int \frac{[\rho_1(\mathbf{r})-\rho_2(\mathbf{r})][\rho_1(\mathbf{r}')-\rho_2(\mathbf{r}')]}{|\mathbf{r}-\mathbf{r}'|}d^3r\,d^3r'\); Folman T³ experiment: cubic scaling of phase shift \(\Delta\phi \propto T^3\) (where \(T\) is free-fall time), testing equivalence principle at quantum level. | CONNECTION: The ratio \(l_P^2/\lambda_C^2\) (Planck length squared over Compton wavelength squared) appears in gravitationally-induced entanglement rates — nume Author: Andrew Stewart Caldin, Independent Researcher, UK. Part of the E8 Intelligence Research series. Platform: e8intelligence.com

•Aug 31, 2026•0 citations
This paper examines whether a fundamental minimum length constrains the correlation length used in spontaneous collapse models. The Planck length is 1.616e-35 metres. For a superposition of one million nucleons separated by one hundred nanometres, the computed collapse-induced decoherence rate varies from 1.000e-10 per second when the correlation length is ten nanometres to 2.500e-15 per second when it is ten micrometres, with 2.212e-11 per second at the conventional one hundred nanometres. Every correlation length under laboratory discussion exceeds the Planck length by more than twenty orders of magnitude, so the minimum length imposes no practical restriction on the parameter; interferometry, not geometry, is what narrows the allowed interval. The study is simulated and computed from stated assumptions; it is not a measurement.
This paper recomputes relative spontaneous-radiation rates for collapse models under the scaling with collapse rate and correlation length used in detector analyses, normalised to a stated reference point. At the conventional parameters the normalised rate is 1.00e-03 in the units adopted here; raising the collapse rate to 1e-10 per second raises the emission to 1.000e+03, while widening the correlation length to one micrometre lowers it to 1.000e-05. The inverse-square dependence on correlation length means radiation searches and interferometric searches probe complementary directions in parameter space, and neither alone closes the plane. All rates here are relative to the stated normalisation; absolute detector limits require the full spectral calculation. The study is simulated and computed from stated assumptions; it is not a measurement.
This paper computes what a maximum mass density implies for the collapse rate in continuous spontaneous localisation models and compares the outcome with laboratory limits. The density ceiling adopted here is 9.717e+57 kilograms per cubic metre on the neutron branch. Translating the ceiling into an energy budget over a Hubble time gives a formal upper value for the collapse rate of 6.753e+57 per second, many orders of magnitude above both the conventional value of 1.00e-16 per second and the stronger value of 1.00e-08 per second sometimes advocated on phenomenological grounds. The associated heating at the conventional rate is only 2.973e-17 watts per kilogram. The ceiling therefore does not restrict the collapse rate within any range currently discussed; the binding restrictions remain the laboratory limits from spontaneous radiation and force-noise measurements, which are tighter by an enormous margin. The study is simulated and computed from stated assumptions; it is not a measurement.
Wavefunction collapse models modify Schrödinger's equation so that it describes the collapse of a superposition of macroscopically distinguishable states as a dynamical process. This provides a basis for the resolution of the quantum measurement problem. An additional generic consequence of the collapse mechanism is that it causes particles to exhibit a tiny random diffusive motion. Here it is shown that for the continuous spontaneous localization (CSL) model—one of the most well developed collapse models—the diffusions of two sufficiently nearby particles are positively correlated. An experimental test of this effect is proposed in which random displacements of pairs of free nanoparticles are measured after they have been simultaneously released from nearby traps. The experiment must be carried out at sufficiently low temperature and pressure in order for the collapse effects to dominate over the ambient environmental noise. It is argued that these constraints can be satisfied by current technologies for a large region of the viable parameter space of the CSL model. The effect disappears as the separation between particles exceeds the CSL length scale. The test therefore provides a means of bounding this length scale.
This paper estimates, under an explicitly stated normalisation, the displacement noise that collapse-model force fluctuations would produce in a gravitational-wave interferometer and compares it with representative detector sensitivity. The displacement amplitude spectral density is 6.333e-29 metres per root hertz at the conventional collapse rate and 6.333e-25 metres per root hertz at a rate of 1e-08 per second, against a representative detector level of 1.00e-19 metres per root hertz near one hundred hertz. On this normalisation the conventional rate lies below detector noise and the stronger rate lies above it, which is why interferometer data already inform the upper part of the parameter range. The normalisation is the main uncertainty and is stated openly. The study is simulated and computed from stated assumptions; it is not a measurement.
Some collapse models proposed that gravitational effects cause the instability of mass distribution superpositions, leading to wave function collapse. In this paper, we utilize the quantum Boltzmann equation (QBE) to analyze the behavior of a fermion in a spatial superposition under graviton emission. We introduce a quantitative measure that links the stability of the superposition to the spatial separation, particle mass, and gravitational coupling. By examining the collision term in the QBE, we derive the decoherence rate and show how it depends on these parameters. Our results provide a detailed framework for understanding gravity induced decoherence, bridging the gap between quantum field theory and collapse models. We also discuss the implications of these findings for experimental tests of gravitationally induced wave function collapse and the broader class of collapse models known as dissipative continuous spontaneous localization (CSL) model.
FINDING: Tabletop quantum-gravity tests probe Planck-scale discreteness via matter-wave interferometry and optomechanical superposition, not yet yielding a confirmed equation but constraining collapse models and graviton signatures. | MATH: Planck length lP=ℏG/c3≈1.616×10−35 ml_P = \sqrt{\hbar G/c^3} \approx 1.616\times10^{-35}\,\text{m}lP​=ℏG/c3​≈1.616×10−35m; Planck mass mP=ℏc/G≈2.176×10−8 kgm_P = \sqrt{\hbar c/G} \approx 2.176\times10^{-8}\,\text{kg}mP​=ℏc/G​≈2.176×10−8kg; decoherence rate for gravitationally-induced collapse (Penrose–Diosi): Γ∼ΔEG/ℏ\Gamma \sim \Delta E_G/\hbarΓ∼ΔEG​/ℏ, where ΔEG=G2∫ ⁣ ⁣∫[ρ1(r)−ρ2(r)][ρ1(r′)−ρ2(r′)]∣r−r′∣d3r d3r′\Delta E_G = \frac{G}{2}\int\!\!\int \frac{[\rho_1(\mathbf{r})-\rho_2(\mathbf{r})][\rho_1(\mathbf{r}')-\rho_2(\mathbf{r}')]}{|\mathbf{r}-\mathbf{r}'|}d^3r\,d^3r'ΔEG​=2G​∫∫∣r−r′∣[ρ1​(r)−ρ2​(r)][ρ1​(r′)−ρ2​(r′)]​d3rd3r′; Folman T³ experiment: cubic scaling of phase shift Δϕ∝T3\Delta\phi \propto T^3Δϕ∝T3 (where TTT is free-fall time), testing equivalence principle at quantum level. | CONNECTION: The ratio lP2/λC2l_P^2/\lambda_C^2lP2​/λC2​ (Planck length squared over Compton wavelength squared) appears in gravitationally-induced entanglement rates — nume Author: Andrew Stewart Caldin, Independent Researcher, UK. Part of the E8 Intelligence Research series. Platform: e8intelligence.com