Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Continuous Spontaneous Localisation Rates Implied by a Maximum Density: A Computed Bound and Laboratory Comparison

William Alexander Aldred

Published Nov 11, 2026• 0 citations
Publisher

Abstract

This paper computes what a maximum mass density implies for the collapse rate in continuous spontaneous localisation models and compares the outcome with laboratory limits. The density ceiling adopted here is 9.717e+57 kilograms per cubic metre on the neutron branch. Translating the ceiling into an energy budget over a Hubble time gives a formal upper value for the collapse rate of 6.753e+57 per second, many orders of magnitude above both the conventional value of 1.00e-16 per second and the stronger value of 1.00e-08 per second sometimes advocated on phenomenological grounds. The associated heating at the conventional rate is only 2.973e-17 watts per kilogram. The ceiling therefore does not restrict the collapse rate within any range currently discussed; the binding restrictions remain the laboratory limits from spontaneous radiation and force-noise measurements, which are tighter by an enormous margin. The study is simulated and computed from stated assumptions; it is not a measurement.

DOI
10.5281/zenodo.24145180

Related papers

Observer Systems and the Density Ceiling: A Computed Bound on Coherent Laboratory Mass

William Alexander Aldred

This paper computes the largest laboratory mass that can remain coherent for one second under gravitational decoherence estimates, as a concrete form of the observer problem in measurement theory. The mass at which the Diósi–Penrose time falls to one second, for ordinary condensed-matter density, is 1.000e-12 kilograms. A mass of 1e-12 kilograms already decoheres in 9.802e-06 seconds and a mass of 1e-09 kilograms in 9.802e-11 seconds in this estimate. The density ceiling itself is never approached at laboratory densities; the operative limitation on coherent observers and memories is gravitational decoherence scaling, not the ceiling. Wigner-friend scenarios with macroscopic coherent laboratories therefore face a quantified timescale obstacle in this model. The study is simulated and computed from stated assumptions; it is not a measurement.

•Nov 11, 2026•0 citations

Granular Localisation Length and the Minimum Length: Bounds on Spontaneous Collapse Width from Interferometry

William Alexander Aldred

This paper examines whether a fundamental minimum length constrains the correlation length used in spontaneous collapse models. The Planck length is 1.616e-35 metres. For a superposition of one million nucleons separated by one hundred nanometres, the computed collapse-induced decoherence rate varies from 1.000e-10 per second when the correlation length is ten nanometres to 2.500e-15 per second when it is ten micrometres, with 2.212e-11 per second at the conventional one hundred nanometres. Every correlation length under laboratory discussion exceeds the Planck length by more than twenty orders of magnitude, so the minimum length imposes no practical restriction on the parameter; interferometry, not geometry, is what narrows the allowed interval. The study is simulated and computed from stated assumptions; it is not a measurement.

•Nov 11, 2026•0 citations

Spontaneous Radiation Bounds on Collapse Models: Recomputed Emission Rates for Germanium Detectors

William Alexander Aldred

This paper recomputes relative spontaneous-radiation rates for collapse models under the scaling with collapse rate and correlation length used in detector analyses, normalised to a stated reference point. At the conventional parameters the normalised rate is 1.00e-03 in the units adopted here; raising the collapse rate to 1e-10 per second raises the emission to 1.000e+03, while widening the correlation length to one micrometre lowers it to 1.000e-05. The inverse-square dependence on correlation length means radiation searches and interferometric searches probe complementary directions in parameter space, and neither alone closes the plane. All rates here are relative to the stated normalisation; absolute detector limits require the full spectral calculation. The study is simulated and computed from stated assumptions; it is not a measurement.

•Nov 11, 2026•0 citations

Diósi–Penrose Gravitational Decoherence Times Across Mass Scales with a Density Ceiling

William Alexander Aldred

This paper evaluates Diósi–Penrose gravitational decoherence times from the electron to macroscopic masses and asks whether a maximum density alters the picture. The computed time is 5.665e+19 seconds for a proton displaced by its own scale, 1.097e+15 seconds for a fullerene molecule, and 1.580e+00 seconds for a dust grain of 1e-15 kilograms. The density ceiling of 9.717e+57 kilograms per cubic metre lies far above the densities of all systems tabulated, so it leaves the standard gravitational decoherence estimates unchanged. The strong mass dependence, not the ceiling, is what separates microscopic superpositions, which persist, from macroscopic ones, which localise promptly in this model. The study is simulated and computed from stated assumptions; it is not a measurement.

•Nov 11, 2026•0 citations

Noninterferometric rotational test of the continuous spontaneous localization model: Enhancement of the collapse noise through shape optimization

Davide Giordano Ario Altamura, Matteo Carlesso, Sandro Donadi +1 more

The continuous spontaneous localization (CSL) model is the most studied among collapse models, which describes the breakdown of the superposition principle for macroscopic systems. Here, we derive an upper bound on the parameters of the model by applying it to the rotational noise measured in a recent short-distance gravity experiment [Lee et al., Phys. Rev. Lett. 124, 101101 (2020)]. Specifically, considering the noise affecting the rotational motion, we found that despite being a tabletop experiment the bound is only one order of magnitude weaker than that from LIGO for the relevant values of the collapse parameter. Further, we analyze possible ways to optimize the shape of the test mass to enhance the collapse noise by several orders of magnitude and eventually derive stronger bounds that can address the unexplored region of the CSL parameters space.

arXiv:2402.13057•Physical Review A•Jun 11, 2024•4 citations

Updating the constraint on the quantum collapse models via kilogram masses

Dai, Qi, Haixing Miao, Yiqiu Ma

Quantum mechanics, which governs all microscopic phenomena, encounters challenges when applied to macroscopic objects that exhibit classical behavior. To address this micro-macro disparity, collapse models such as the Continuous Spontaneous Localization (CSL) and Diosi-Penrose (DP) models have been proposed. These models phenomenologically modify quantum theory to reconcile its predictions with the observed classical behavior of macroscopic systems. Based on previous works\,([Phys.\,Rev\,D,\,95(8):084054\,(2017)] and [Phys.\,Rev.\,D,\,94:124036,\,(2016)]), an improved bound on the collapse model parameters is given using the updated acceleration noise data released from LISA Pathfinder\,([Phys.\,Rev.\,D, 110(4):042004,\,(2024)]). The CSL collapse rate is bounded to be at most $λ_{\rm CSL} \leq 8.3\times 10^{-11}$\,$s^{-1}$ at the mili-Hertz band when $r_{\rm CSL}=10^{-7}\,{\rm m}$, and the DP model's regularization cut-off scale is constraint to be $σ_{\rm DP}\sim 285.5$\,fm. Furthermore, we discuss the potential advantages of using deep-underground laboratories to test these quantum collapse models. Our results show the quiet seismic condition of the current deep-underground laboratory has the potential to further constrain the CSL collapse model to $λ_{\rm CSL}\leq3\times 10^{-11}\,{\rm s}^{-1}$ when $r_{\rm CSL}=10^{-7}\,{\rm m}$.

arXiv:2411.17588•Nov 26, 2024•1 citation
This paper computes what a maximum mass density implies for the collapse rate in continuous spontaneous localisation models and compares the outcome with laboratory limits. The density ceiling adopted here is 9.717e+57 kilograms per cubic metre on the neutron branch. Translating the ceiling into an energy budget over a Hubble time gives a formal upper value for the collapse rate of 6.753e+57 per second, many orders of magnitude above both the conventional value of 1.00e-16 per second and the stronger value of 1.00e-08 per second sometimes advocated on phenomenological grounds. The associated heating at the conventional rate is only 2.973e-17 watts per kilogram. The ceiling therefore does not restrict the collapse rate within any range currently discussed; the binding restrictions remain the laboratory limits from spontaneous radiation and force-noise measurements, which are tighter by an enormous margin. The study is simulated and computed from stated assumptions; it is not a measurement.
This paper computes the largest laboratory mass that can remain coherent for one second under gravitational decoherence estimates, as a concrete form of the observer problem in measurement theory. The mass at which the Diósi–Penrose time falls to one second, for ordinary condensed-matter density, is 1.000e-12 kilograms. A mass of 1e-12 kilograms already decoheres in 9.802e-06 seconds and a mass of 1e-09 kilograms in 9.802e-11 seconds in this estimate. The density ceiling itself is never approached at laboratory densities; the operative limitation on coherent observers and memories is gravitational decoherence scaling, not the ceiling. Wigner-friend scenarios with macroscopic coherent laboratories therefore face a quantified timescale obstacle in this model. The study is simulated and computed from stated assumptions; it is not a measurement.
This paper examines whether a fundamental minimum length constrains the correlation length used in spontaneous collapse models. The Planck length is 1.616e-35 metres. For a superposition of one million nucleons separated by one hundred nanometres, the computed collapse-induced decoherence rate varies from 1.000e-10 per second when the correlation length is ten nanometres to 2.500e-15 per second when it is ten micrometres, with 2.212e-11 per second at the conventional one hundred nanometres. Every correlation length under laboratory discussion exceeds the Planck length by more than twenty orders of magnitude, so the minimum length imposes no practical restriction on the parameter; interferometry, not geometry, is what narrows the allowed interval. The study is simulated and computed from stated assumptions; it is not a measurement.
This paper recomputes relative spontaneous-radiation rates for collapse models under the scaling with collapse rate and correlation length used in detector analyses, normalised to a stated reference point. At the conventional parameters the normalised rate is 1.00e-03 in the units adopted here; raising the collapse rate to 1e-10 per second raises the emission to 1.000e+03, while widening the correlation length to one micrometre lowers it to 1.000e-05. The inverse-square dependence on correlation length means radiation searches and interferometric searches probe complementary directions in parameter space, and neither alone closes the plane. All rates here are relative to the stated normalisation; absolute detector limits require the full spectral calculation. The study is simulated and computed from stated assumptions; it is not a measurement.
This paper evaluates Diósi–Penrose gravitational decoherence times from the electron to macroscopic masses and asks whether a maximum density alters the picture. The computed time is 5.665e+19 seconds for a proton displaced by its own scale, 1.097e+15 seconds for a fullerene molecule, and 1.580e+00 seconds for a dust grain of 1e-15 kilograms. The density ceiling of 9.717e+57 kilograms per cubic metre lies far above the densities of all systems tabulated, so it leaves the standard gravitational decoherence estimates unchanged. The strong mass dependence, not the ceiling, is what separates microscopic superpositions, which persist, from macroscopic ones, which localise promptly in this model. The study is simulated and computed from stated assumptions; it is not a measurement.
The continuous spontaneous localization (CSL) model is the most studied among collapse models, which describes the breakdown of the superposition principle for macroscopic systems. Here, we derive an upper bound on the parameters of the model by applying it to the rotational noise measured in a recent short-distance gravity experiment [Lee et al., Phys. Rev. Lett. 124, 101101 (2020)]. Specifically, considering the noise affecting the rotational motion, we found that despite being a tabletop experiment the bound is only one order of magnitude weaker than that from LIGO for the relevant values of the collapse parameter. Further, we analyze possible ways to optimize the shape of the test mass to enhance the collapse noise by several orders of magnitude and eventually derive stronger bounds that can address the unexplored region of the CSL parameters space.
Quantum mechanics, which governs all microscopic phenomena, encounters challenges when applied to macroscopic objects that exhibit classical behavior. To address this micro-macro disparity, collapse models such as the Continuous Spontaneous Localization (CSL) and Diosi-Penrose (DP) models have been proposed. These models phenomenologically modify quantum theory to reconcile its predictions with the observed classical behavior of macroscopic systems. Based on previous works\,([Phys.\,Rev\,D,\,95(8):084054\,(2017)] and [Phys.\,Rev.\,D,\,94:124036,\,(2016)]), an improved bound on the collapse model parameters is given using the updated acceleration noise data released from LISA Pathfinder\,([Phys.\,Rev.\,D, 110(4):042004,\,(2024)]). The CSL collapse rate is bounded to be at most λCSL≤8.3×10−11λ_{\rm CSL} \leq 8.3\times 10^{-11}λCSL​≤8.3×10−11\,s−1s^{-1}s−1 at the mili-Hertz band when rCSL=10−7 mr_{\rm CSL}=10^{-7}\,{\rm m}rCSL​=10−7m, and the DP model's regularization cut-off scale is constraint to be σDP∼285.5σ_{\rm DP}\sim 285.5σDP​∼285.5\,fm. Furthermore, we discuss the potential advantages of using deep-underground laboratories to test these quantum collapse models. Our results show the quiet seismic condition of the current deep-underground laboratory has the potential to further constrain the CSL collapse model to λCSL≤3×10−11 s−1λ_{\rm CSL}\leq3\times 10^{-11}\,{\rm s}^{-1}λCSL​≤3×10−11s−1 when rCSL=10−7 mr_{\rm CSL}=10^{-7}\,{\rm m}rCSL​=10−7m.