Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

A Spin-Polarisation Magnetometer: Computed Sensitivity of a Dense Polarised Alkali Ensemble

William Alexander Aldred

Published Nov 11, 2026• 1 citation
Publisher

Abstract

A dense, highly polarised alkali vapour is a magnetic sensor whose fundamental noise limits lie far below what practical instruments achieve, and the gap between the two is where magnetometer design actually happens. This paper specifies a spin-polarisation magnetometer on such an ensemble, 7.20e+14 atoms at a polarisation of 0.85 with a coherence time of twelve milliseconds, and computes each limit separately: spin projection noise at 0.0019 femtotesla per root hertz, photon shot noise at 0.0031 femtotesla per root hertz, and a technical floor of 0.55 femtotesla per root hertz that dominates the total of 0.55 femtotesla per root hertz. The measurement bandwidth is 13 hertz and the operating range is plus or minus five nanotesla around a compensated zero, requiring a shielding and compensation factor of 1e+04 against the ambient geomagnetic field. SIMULATED, NOT MEASURED: the figures are computed from the stated assumptions and no instrument has been operated.

DOI
10.5281/zenodo.24129592

Related papers

High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation

J. C. Allred, ROBERT LYMAN, Thomas W. Kornack +1 more

Alkali-metal magnetometers compete with SQUID detectors as the most sensitive magnetic field sensors. Their sensitivity is limited by relaxation due to spin-exchange collisions. We demonstrate a K magnetometer in which spin-exchange relaxation is completely eliminated by operating at high K density and low magnetic field. Direct measurements of the signal-to-noise ratio give a magnetometer sensitivity of $10\text{ }\mathrm{f}\mathrm{T}\text{ }\mathrm{H}{\mathrm{z}}^{\mathrm{\ensuremath{-}}\mathrm{1}\mathrm{/}\mathrm{2}}$, limited by magnetic noise produced by Johnson currents in the magnetic shields. We extend a previous theoretical analysis of spin exchange in low magnetic fields to arbitrary spin polarizations and estimate the shot-noise limit of the magnetometer to be $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}\text{ }\mathrm{T}\text{ }\mathrm{H}{\mathrm{z}}^{\mathrm{\ensuremath{-}}\mathrm{1}\mathrm{/}\mathrm{2}}$.

Physical Review Letters•Sep 9, 2002•1,078 citations

Magnetic-field-independent spin-exchange relaxation-free magnetometer

Mark Dikopoltsev, Uriel Levy, Or Katz

Spin-exchange relaxation-free magnetometers based on dense ensembles of alkali-metal spins are precision quantum sensors that hold the record of measured and projected sensitivity to magnetic fields, in the microgauss to milligauss range. At geomagnetic fields however, these sensors quickly lose their magnetic sensitivity due to spin decoherence by random spin-exchange collisions. Here we discover that atoms with nuclear spin $I=\frac{1}{2}$ can operate in the spin-exchange relaxation-free regime even at high magnetic field. We counterintuitively show that frequent collisions between a dense and optically inaccessible $(I=\frac{1}{2})$ gas with another optically accessible spin gas ($I>\frac{1}{2}$) improve the fundamental magnetic sensitivity of the latter. We analyze the performance of a dual-species potassium and atomic hydrogen magnetometer and project a fundamental sensitivity of about $10\phantom{\rule{0.28em}{0ex}}\mathrm{aT}\phantom{\rule{0.16em}{0ex}}{({\mathrm{cm}}^{3}\text{/}\mathrm{Hz})}^{1/2}$ at geomagnetic fields for feasible experimental conditions.

arXiv:2209.13086•Physical Review A•Mar 3, 2025•9 citations

Continuous High-Sensitivity and High-Bandwidth Atomic Magnetometer

Rujie Li, Fred N. Baynes, Andre Nicholas Luiten +1 more

Here we demonstrate an atomic magnetometer that has a bandwidth of more than 100 kHz and a sensitivity of $180\phantom{\rule{0.2em}{0ex}}\mathrm{fT/}\ensuremath{\surd}\mathrm{Hz}$ at a Fourier frequency of 8 Hz, and $0.7\phantom{\rule{0.2em}{0ex}}\mathrm{nT/}\ensuremath{\surd}\mathrm{Hz}$ at 100 kHz. These sensitivity measurements are achieved at geophysically useful magnetic field magnitudes (approximately $50\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{T}$ inside a three-layer $\ensuremath{\mu}$-metal shield) and are limited by the photon shot noise for frequencies above 8 Hz. This device is based on a nonlinear magneto-optical rotation sensor that is operated with an active feedback to the pump modulation frequency. We present a theoretical description of the response functions of the components in the magnetometer. We show that the range of operation of atomic magnetometers can thus be expanded beyond the conventional high-sensitivity, low-bandwidth domain, to provide a high-linearity, high-bandwidth, and high-sensitivity sensor.

Physical Review Applied•Dec 23, 2020•78 citations

Experimental light-squeezing-enhanced magnetometry

Alessandro Ceré, Florian Wolfgramm, Federica A. Beduini +3 more

The ability to measure magnetic fields with high sensitivity is a key requirement in many physical, biological and medical applications. Currently the most sensitive magnetometers are optical magnetometers, in which the polarization of an atomic sample responds to the field and is read out by an optical measurement. These instruments are limited by two fundamental sources of quantum noise: projection noise of the atoms and shot noise of the light. For magnetometers designed to have a high statistical sensitivity, contributions from both sources are comparable. Here we show that the sensitivity can be improved by the application of non-classical light.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2011•0 citations

High-bandwidth optical magnetometer

Ricardo Jiménez-Martínez, W. C. Griffith, Svenja A. Knappe +2 more

We demonstrate a scalar Rb87 optical magnetometer that retains magnetic-field sensitivities below 10pT/√Hzover 3 dB bandwidths of 10 kHz in an ambient field Bo=11.4 μT and using a measurement volume of 1 mm3. The magnetometer operates at high atomic densities where both the sensitivity and the bandwidth are limited by spin-exchange collisions between the alkali atoms. By operating in this regime, our measurements show that the bandwidth of the magnetometer can be increased without a significant degradation in its sensitivity.

Journal of the Optical Society of America B•Nov 28, 2012•61 citations

Ultra-sensitive atomic magnetometers and their applications

M. V. Romalis

In this paper, a new type of high-sensitivity magnetometer that can surpass SQUID magnetometers operating in liquid-helium in sensitivity and spatial resolution is discussed. The sensitivity of atomic magnetometers is determined by the electron spin relaxation time and the number of alkali-metal atoms. The relaxation time is usually limited by spin-exchange collisions between atoms and drops at higher alkali-metal density. Spin-exchange collisions preserve the total spin of the atoms, but can change their hyperfine state, which reverses the direction of spin precession in the magnetic field. Thus, spin-exchange collisions usually cause spin decoherence. However, this relaxation process can be suppressed if the spin precession frequency is much smaller than the rate of spin-exchange collisions. These conditions lead to 'motional narrowing', where the spin precession angle between the collisions is so small that the atoms do not lose coherence. A magnetometer operating near zero magnetic field can simultaneously achieve high alkali-metal density and long spin-relaxation time, resulting in very high sensitivity.

IEEE International Magnetics Conference•May 1, 2006•0 citations
A dense, highly polarised alkali vapour is a magnetic sensor whose fundamental noise limits lie far below what practical instruments achieve, and the gap between the two is where magnetometer design actually happens. This paper specifies a spin-polarisation magnetometer on such an ensemble, 7.20e+14 atoms at a polarisation of 0.85 with a coherence time of twelve milliseconds, and computes each limit separately: spin projection noise at 0.0019 femtotesla per root hertz, photon shot noise at 0.0031 femtotesla per root hertz, and a technical floor of 0.55 femtotesla per root hertz that dominates the total of 0.55 femtotesla per root hertz. The measurement bandwidth is 13 hertz and the operating range is plus or minus five nanotesla around a compensated zero, requiring a shielding and compensation factor of 1e+04 against the ambient geomagnetic field. SIMULATED, NOT MEASURED: the figures are computed from the stated assumptions and no instrument has been operated.
Alkali-metal magnetometers compete with SQUID detectors as the most sensitive magnetic field sensors. Their sensitivity is limited by relaxation due to spin-exchange collisions. We demonstrate a K magnetometer in which spin-exchange relaxation is completely eliminated by operating at high K density and low magnetic field. Direct measurements of the signal-to-noise ratio give a magnetometer sensitivity of $10\text{ }\mathrm{f}\mathrm{T}\text{ }\mathrm{H}{\mathrm{z}}^{\mathrm{\ensuremath{-}}\mathrm{1}\mathrm{/}\mathrm{2}}$, limited by magnetic noise produced by Johnson currents in the magnetic shields. We extend a previous theoretical analysis of spin exchange in low magnetic fields to arbitrary spin polarizations and estimate the shot-noise limit of the magnetometer to be $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}\text{ }\mathrm{T}\text{ }\mathrm{H}{\mathrm{z}}^{\mathrm{\ensuremath{-}}\mathrm{1}\mathrm{/}\mathrm{2}}$.
Spin-exchange relaxation-free magnetometers based on dense ensembles of alkali-metal spins are precision quantum sensors that hold the record of measured and projected sensitivity to magnetic fields, in the microgauss to milligauss range. At geomagnetic fields however, these sensors quickly lose their magnetic sensitivity due to spin decoherence by random spin-exchange collisions. Here we discover that atoms with nuclear spin I=12I=\frac{1}{2}I=21​ can operate in the spin-exchange relaxation-free regime even at high magnetic field. We counterintuitively show that frequent collisions between a dense and optically inaccessible (I=12)(I=\frac{1}{2})(I=21​) gas with another optically accessible spin gas (I>12I>\frac{1}{2}I>21​) improve the fundamental magnetic sensitivity of the latter. We analyze the performance of a dual-species potassium and atomic hydrogen magnetometer and project a fundamental sensitivity of about 10aT(cm3/Hz)1/210\phantom{\rule{0.28em}{0ex}}\mathrm{aT}\phantom{\rule{0.16em}{0ex}}{({\mathrm{cm}}^{3}\text{/}\mathrm{Hz})}^{1/2}10aT(cm3/Hz)1/2 at geomagnetic fields for feasible experimental conditions.
Here we demonstrate an atomic magnetometer that has a bandwidth of more than 100 kHz and a sensitivity of $180\phantom{\rule{0.2em}{0ex}}\mathrm{fT/}\ensuremath{\surd}\mathrm{Hz}$ at a Fourier frequency of 8 Hz, and $0.7\phantom{\rule{0.2em}{0ex}}\mathrm{nT/}\ensuremath{\surd}\mathrm{Hz}$ at 100 kHz. These sensitivity measurements are achieved at geophysically useful magnetic field magnitudes (approximately $50\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{T}$ inside a three-layer $\ensuremath{\mu}$-metal shield) and are limited by the photon shot noise for frequencies above 8 Hz. This device is based on a nonlinear magneto-optical rotation sensor that is operated with an active feedback to the pump modulation frequency. We present a theoretical description of the response functions of the components in the magnetometer. We show that the range of operation of atomic magnetometers can thus be expanded beyond the conventional high-sensitivity, low-bandwidth domain, to provide a high-linearity, high-bandwidth, and high-sensitivity sensor.
The ability to measure magnetic fields with high sensitivity is a key requirement in many physical, biological and medical applications. Currently the most sensitive magnetometers are optical magnetometers, in which the polarization of an atomic sample responds to the field and is read out by an optical measurement. These instruments are limited by two fundamental sources of quantum noise: projection noise of the atoms and shot noise of the light. For magnetometers designed to have a high statistical sensitivity, contributions from both sources are comparable. Here we show that the sensitivity can be improved by the application of non-classical light.
We demonstrate a scalar Rb87 optical magnetometer that retains magnetic-field sensitivities below 10pT/√Hzover 3 dB bandwidths of 10 kHz in an ambient field Bo=11.4 μT and using a measurement volume of 1 mm3. The magnetometer operates at high atomic densities where both the sensitivity and the bandwidth are limited by spin-exchange collisions between the alkali atoms. By operating in this regime, our measurements show that the bandwidth of the magnetometer can be increased without a significant degradation in its sensitivity.
In this paper, a new type of high-sensitivity magnetometer that can surpass SQUID magnetometers operating in liquid-helium in sensitivity and spatial resolution is discussed. The sensitivity of atomic magnetometers is determined by the electron spin relaxation time and the number of alkali-metal atoms. The relaxation time is usually limited by spin-exchange collisions between atoms and drops at higher alkali-metal density. Spin-exchange collisions preserve the total spin of the atoms, but can change their hyperfine state, which reverses the direction of spin precession in the magnetic field. Thus, spin-exchange collisions usually cause spin decoherence. However, this relaxation process can be suppressed if the spin precession frequency is much smaller than the rate of spin-exchange collisions. These conditions lead to 'motional narrowing', where the spin precession angle between the collisions is so small that the atoms do not lose coherence. A magnetometer operating near zero magnetic field can simultaneously achieve high alkali-metal density and long spin-relaxation time, resulting in very high sensitivity.