Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

High-bandwidth optical magnetometer

Ricardo Jiménez-Martínez, W. C. Griffith, Svenja A. Knappe, John E. Kitching, Mark D. Prouty

Published Nov 28, 2012• 59 citations
Publisher

Abstract

We demonstrate a scalar Rb87 optical magnetometer that retains magnetic-field sensitivities below 10pT/√Hzover 3 dB bandwidths of 10 kHz in an ambient field Bo=11.4 μT and using a measurement volume of 1 mm3. The magnetometer operates at high atomic densities where both the sensitivity and the bandwidth are limited by spin-exchange collisions between the alkali atoms. By operating in this regime, our measurements show that the bandwidth of the magnetometer can be increased without a significant degradation in its sensitivity.

DOI
10.1364/josab.29.003398

Related papers

Low-noise high-density alkali-metal scalar magnetometer

Sylvia Smullin, Igor Savukov, Georgios Vasilakis +2 more

We present an experimental and theoretical study of a scalar atomic magnetometer using an oscillating field-driven Zeeman resonance in a high-density optically pumped potassium vapor. We describe an experimental implementation of an atomic gradiometer with a noise level below $10\text{ }\text{fT}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, fractional field sensitivity below ${10}^{\ensuremath{-}9}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, and an active measurement volume of about $1.5\text{ }{\text{cm}}^{3}$. We show that the fundamental field sensitivity of a scalar magnetometer is determined by the rate of alkali-metal spin-exchange collisions even though the resonance linewidth can be made much smaller than the spin-exchange rate by pumping most atoms into a stretched spin state.

arXiv:physics/0611085•Physical Review A•Sep 29, 2009•140 citations

Ultra-sensitive atomic magnetometers and their applications

M. V. Romalis

In this paper, a new type of high-sensitivity magnetometer that can surpass SQUID magnetometers operating in liquid-helium in sensitivity and spatial resolution is discussed. The sensitivity of atomic magnetometers is determined by the electron spin relaxation time and the number of alkali-metal atoms. The relaxation time is usually limited by spin-exchange collisions between atoms and drops at higher alkali-metal density. Spin-exchange collisions preserve the total spin of the atoms, but can change their hyperfine state, which reverses the direction of spin precession in the magnetic field. Thus, spin-exchange collisions usually cause spin decoherence. However, this relaxation process can be suppressed if the spin precession frequency is much smaller than the rate of spin-exchange collisions. These conditions lead to 'motional narrowing', where the spin precession angle between the collisions is so small that the atoms do not lose coherence. A magnetometer operating near zero magnetic field can simultaneously achieve high alkali-metal density and long spin-relaxation time, resulting in very high sensitivity.

IEEE International Magnetics Conference•May 1, 2006•0 citations

Broadband Ultra-Sensitive Adiabatic Magnetometer

Igor Savukov, Young Jin Kim

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. We experimentally conducted alkali-metal density measurements, as an example of applications.

IEEE Sensors Applications Symposium (SAS)•Aug 23, 2021•1 citation

Continuous High-Sensitivity and High-Bandwidth Atomic Magnetometer

Rujie Li, Fred N. Baynes, Andre Nicholas Luiten +1 more

Here we demonstrate an atomic magnetometer that has a bandwidth of more than 100 kHz and a sensitivity of $180\phantom{\rule{0.2em}{0ex}}\mathrm{fT/}\ensuremath{\surd}\mathrm{Hz}$ at a Fourier frequency of 8 Hz, and $0.7\phantom{\rule{0.2em}{0ex}}\mathrm{nT/}\ensuremath{\surd}\mathrm{Hz}$ at 100 kHz. These sensitivity measurements are achieved at geophysically useful magnetic field magnitudes (approximately $50\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{T}$ inside a three-layer $\ensuremath{\mu}$-metal shield) and are limited by the photon shot noise for frequencies above 8 Hz. This device is based on a nonlinear magneto-optical rotation sensor that is operated with an active feedback to the pump modulation frequency. We present a theoretical description of the response functions of the components in the magnetometer. We show that the range of operation of atomic magnetometers can thus be expanded beyond the conventional high-sensitivity, low-bandwidth domain, to provide a high-linearity, high-bandwidth, and high-sensitivity sensor.

Physical Review Applied•Dec 23, 2020•75 citations

High Bandwidth Atomic Magnetometery with Continuous Quantum Nondemolition Measurements

Vishal Shah, Georgios Vasilakis, Michael V. Romalis

We describe an experimental study of spin-projection noise in a high sensitivity alkali-metal magnetometer. We demonstrate a fourfold improvement in the measurement bandwidth of the magnetometer using continuous quantum nondemolition measurements. Operating in the scalar mode with a measurement volume of 2 cm3 we achieve magnetic field sensitivity of 22 fT/Hz(1/2) and a bandwidth of 1.9 kHz with a spin polarization of only 1%. Our experimental arrangement is naturally backaction evading and can be used to realize sub-fT sensitivity with a highly polarized spin-squeezed atomic vapor.

arXiv:0907.2241•Physical Review Letters•Jan 5, 2010•150 citations

Three-axis closed-loop optically pumped magnetometer operated in the SERF regime

Yeguang Yan, Jixi Lu, Shaowen Zhang +5 more

We propose a three-axis closed-loop optically pumped magnetometer with high sensitivity. The closed-loop magnetometer has a three-axis sensitivity of approximately 30 fT/Hz 1/2 using two orthogonal laser beams for pumping and probing the alkali metal atoms. In the closed-loop mode, the dynamic range is improved from ±5 nT to ±150 nT. The bandwidth is increased from about 100 Hz to over 2 kHz with 10 kHz modulation fields in x - and y -axes and another 6 kHz modulation field along the z -axis. Compared with single-axis or dual-axis magnetometers, the proposed magnetometer not only provides the direction and magnitude of the magnetic field but also has high robustness in a challenging environment. The magnetometer has applications in biomagnetic measurements, magnetic resonance imaging, and fundamental physics.

Optics Express•May 4, 2022•85 citations
We demonstrate a scalar Rb87 optical magnetometer that retains magnetic-field sensitivities below 10pT/√Hzover 3 dB bandwidths of 10 kHz in an ambient field Bo=11.4 μT and using a measurement volume of 1 mm3. The magnetometer operates at high atomic densities where both the sensitivity and the bandwidth are limited by spin-exchange collisions between the alkali atoms. By operating in this regime, our measurements show that the bandwidth of the magnetometer can be increased without a significant degradation in its sensitivity.
We present an experimental and theoretical study of a scalar atomic magnetometer using an oscillating field-driven Zeeman resonance in a high-density optically pumped potassium vapor. We describe an experimental implementation of an atomic gradiometer with a noise level below $10\text{ }\text{fT}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, fractional field sensitivity below ${10}^{\ensuremath{-}9}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, and an active measurement volume of about 1.5 cm31.5\text{ }{\text{cm}}^{3}1.5 cm3. We show that the fundamental field sensitivity of a scalar magnetometer is determined by the rate of alkali-metal spin-exchange collisions even though the resonance linewidth can be made much smaller than the spin-exchange rate by pumping most atoms into a stretched spin state.
In this paper, a new type of high-sensitivity magnetometer that can surpass SQUID magnetometers operating in liquid-helium in sensitivity and spatial resolution is discussed. The sensitivity of atomic magnetometers is determined by the electron spin relaxation time and the number of alkali-metal atoms. The relaxation time is usually limited by spin-exchange collisions between atoms and drops at higher alkali-metal density. Spin-exchange collisions preserve the total spin of the atoms, but can change their hyperfine state, which reverses the direction of spin precession in the magnetic field. Thus, spin-exchange collisions usually cause spin decoherence. However, this relaxation process can be suppressed if the spin precession frequency is much smaller than the rate of spin-exchange collisions. These conditions lead to 'motional narrowing', where the spin precession angle between the collisions is so small that the atoms do not lose coherence. A magnetometer operating near zero magnetic field can simultaneously achieve high alkali-metal density and long spin-relaxation time, resulting in very high sensitivity.
We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. We experimentally conducted alkali-metal density measurements, as an example of applications.
Here we demonstrate an atomic magnetometer that has a bandwidth of more than 100 kHz and a sensitivity of $180\phantom{\rule{0.2em}{0ex}}\mathrm{fT/}\ensuremath{\surd}\mathrm{Hz}$ at a Fourier frequency of 8 Hz, and $0.7\phantom{\rule{0.2em}{0ex}}\mathrm{nT/}\ensuremath{\surd}\mathrm{Hz}$ at 100 kHz. These sensitivity measurements are achieved at geophysically useful magnetic field magnitudes (approximately $50\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{T}$ inside a three-layer $\ensuremath{\mu}$-metal shield) and are limited by the photon shot noise for frequencies above 8 Hz. This device is based on a nonlinear magneto-optical rotation sensor that is operated with an active feedback to the pump modulation frequency. We present a theoretical description of the response functions of the components in the magnetometer. We show that the range of operation of atomic magnetometers can thus be expanded beyond the conventional high-sensitivity, low-bandwidth domain, to provide a high-linearity, high-bandwidth, and high-sensitivity sensor.
We describe an experimental study of spin-projection noise in a high sensitivity alkali-metal magnetometer. We demonstrate a fourfold improvement in the measurement bandwidth of the magnetometer using continuous quantum nondemolition measurements. Operating in the scalar mode with a measurement volume of 2 cm3 we achieve magnetic field sensitivity of 22 fT/Hz(1/2) and a bandwidth of 1.9 kHz with a spin polarization of only 1%. Our experimental arrangement is naturally backaction evading and can be used to realize sub-fT sensitivity with a highly polarized spin-squeezed atomic vapor.
We propose a three-axis closed-loop optically pumped magnetometer with high sensitivity. The closed-loop magnetometer has a three-axis sensitivity of approximately 30 fT/Hz 1/2 using two orthogonal laser beams for pumping and probing the alkali metal atoms. In the closed-loop mode, the dynamic range is improved from ±5 nT to ±150 nT. The bandwidth is increased from about 100 Hz to over 2 kHz with 10 kHz modulation fields in x - and y -axes and another 6 kHz modulation field along the z -axis. Compared with single-axis or dual-axis magnetometers, the proposed magnetometer not only provides the direction and magnitude of the magnetic field but also has high robustness in a challenging environment. The magnetometer has applications in biomagnetic measurements, magnetic resonance imaging, and fundamental physics.