arXiv:physics/0611085 · Physical Review A

Low-noise high-density alkali-metal scalar magnetometer

Sylvia Smullin, Igor Savukov, Georgios Vasilakis, Rajat K. Ghosh, Michael V. Romalis

Published Sep 29, 2009• 143 citations
arXivHTMLPDF

Abstract

We present an experimental and theoretical study of a scalar atomic magnetometer using an oscillating field-driven Zeeman resonance in a high-density optically pumped potassium vapor. We describe an experimental implementation of an atomic gradiometer with a noise level below $10\text{ }\text{fT}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, fractional field sensitivity below ${10}^{\ensuremath{-}9}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, and an active measurement volume of about $1.5\text{ }{\text{cm}}^{3}$. We show that the fundamental field sensitivity of a scalar magnetometer is determined by the rate of alkali-metal spin-exchange collisions even though the resonance linewidth can be made much smaller than the spin-exchange rate by pumping most atoms into a stretched spin state.

DOI
10.1103/physreva.80.033420

Related papers

Tunable Atomic Magnetometer for Detection of Radio-Frequency Magnetic Fields

Igor Savukov, Scott J. Seltzer, Michael V. Romalis +1 more

We describe an alkali-metal magnetometer for detection of weak magnetic fields in the radio-frequency (rf) range. High sensitivity is achieved by tuning the Zeeman resonance of alkali atoms to the rf frequency and partially suppressing spin-exchange collisions in the alkali-metal vapor. We demonstrate magnetic field sensitivity of 2 fT/Hz(1/2) at a frequency of 99 kHz with a resonance width of 400 Hz. We also derive a simple analytic expression for the fundamental limit on the sensitivity of the rf magnetometer and show that a sensitivity of about 0.01 fT/Hz(1/2) can be achieved in a practical system with a measurement volume of 200 cm3.

Physical Review Letters•Aug 3, 2005•346 citations

Effects of spin-exchange collisions in a high-density alkali-metal vapor in low magnetic fields

Igor Savukov, Michael V. Romalis

Spin-exchange collisions often play a dominant role in the broadening of Zeeman resonances in an alkali-metal vapor. Contrary to intuitive expectations, at high alkali-metal densities this broadening can be completely eliminated by operating in a low magnetic field, allowing construction of ultrasensitive atomic magnetometers. We describe a detailed study of the Zeeman resonance frequencies and linewidths as a function of the magnetic field, alkali-metal density, and the degree of spin polarization of the atoms. Due to the nonlinear nature of the density matrix equations describing the spin-exchange collisions both the gyromagnetic ratio and the linewidth change as a function of the polarization. The results of experimental measurements are in excellent agreement with analytical and numerical solutions of the density matrix equations.

Physical Review A•Feb 10, 2005•247 citations

Compact, high-sensitivity atomic magnetometer utilizing the light-narrowing effect and in-phase excitation

Yuhao Guo, Shuangai Wan, Xiaoguang Sun +1 more

A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.

Applied Optics•Jan 22, 2019•30 citations

Broadband Ultra-Sensitive Adiabatic Magnetometer

Igor Savukov, Young Jin Kim

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. We experimentally conducted alkali-metal density measurements, as an example of applications.

IEEE Sensors Applications Symposium (SAS)•Aug 23, 2021•2 citations

Accurate determination of alkali atom density based on zero-field magnetic resonance in a single-beam spin-exchange relaxation-free atomic magnetometer

Yintao Ma, Yao Chen, Libo Zhao +6 more

A single-beam spin-exchange relaxation-free (SERF) atomic magnetometer can extract vector magnetic field information by detecting the transmission intensity of a resonant circularly polarized pumping beam, which depends sensitively on the atomic density of the alkali metal. We present a novel scheme to determine atomic density based on zero-field magnetic resonance. The resonance linewidth under different transverse DC magnetic fields is fitted by means of a quadratic function. The atomic density can be extracted from the quadratic coefficients of the fitted function. The experimental results indicate that the deviation of measured density is less than two times compared with the theoretical values between 378 K and 403 K. Furthermore, the influence of modulation field on resonance linewidth is investigated experimentally and theoretically. A miniature single-beam SERF atomic magnetometer with a sensor head volume of only 16.2 cm 3 and the measuring sensitivity of 40 fT/ Hz 1/2 has been achieved. These results should be beneficial for guiding the development of a chip-scale atomic magnetometer with high sensitivity and spatial resolution for bio-magnetic field imaging applications.

Measurement Science and Technology•Jul 5, 2022•11 citations

Spin-exchange-relaxation-free magnetometry with Cs vapor

M. P. Ledbetter, Igor Savukov, Víctor M. Acosta +2 more

We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about $400\text{ }\text{pG}/\sqrt{\text{Hz}}$. Based on photon shot noise, we project a sensitivity of $40\text{ }\text{pG}/\sqrt{\text{Hz}}$. A theoretical optimization of the magnetometer indicates sensitivities on the order of $2\text{ }\text{pG}/\sqrt{\text{Hz}}$ should be achievable in a $1\text{ }{\text{cm}}^{3}$ volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.

arXiv:0708.1012•Physical Review A•Mar 13, 2008•429 citations
We present an experimental and theoretical study of a scalar atomic magnetometer using an oscillating field-driven Zeeman resonance in a high-density optically pumped potassium vapor. We describe an experimental implementation of an atomic gradiometer with a noise level below 10 fT Hz\ensuremath−1/210\text{ }\text{fT}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}10 fT Hz\ensuremath−1/2, fractional field sensitivity below 10\ensuremath−9 Hz\ensuremath−1/2{10}^{\ensuremath{-}9}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}10\ensuremath−9 Hz\ensuremath−1/2, and an active measurement volume of about 1.5 cm31.5\text{ }{\text{cm}}^{3}1.5 cm3. We show that the fundamental field sensitivity of a scalar magnetometer is determined by the rate of alkali-metal spin-exchange collisions even though the resonance linewidth can be made much smaller than the spin-exchange rate by pumping most atoms into a stretched spin state.
We describe an alkali-metal magnetometer for detection of weak magnetic fields in the radio-frequency (rf) range. High sensitivity is achieved by tuning the Zeeman resonance of alkali atoms to the rf frequency and partially suppressing spin-exchange collisions in the alkali-metal vapor. We demonstrate magnetic field sensitivity of 2 fT/Hz(1/2) at a frequency of 99 kHz with a resonance width of 400 Hz. We also derive a simple analytic expression for the fundamental limit on the sensitivity of the rf magnetometer and show that a sensitivity of about 0.01 fT/Hz(1/2) can be achieved in a practical system with a measurement volume of 200 cm3.
Spin-exchange collisions often play a dominant role in the broadening of Zeeman resonances in an alkali-metal vapor. Contrary to intuitive expectations, at high alkali-metal densities this broadening can be completely eliminated by operating in a low magnetic field, allowing construction of ultrasensitive atomic magnetometers. We describe a detailed study of the Zeeman resonance frequencies and linewidths as a function of the magnetic field, alkali-metal density, and the degree of spin polarization of the atoms. Due to the nonlinear nature of the density matrix equations describing the spin-exchange collisions both the gyromagnetic ratio and the linewidth change as a function of the polarization. The results of experimental measurements are in excellent agreement with analytical and numerical solutions of the density matrix equations.
A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.
We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. We experimentally conducted alkali-metal density measurements, as an example of applications.
A single-beam spin-exchange relaxation-free (SERF) atomic magnetometer can extract vector magnetic field information by detecting the transmission intensity of a resonant circularly polarized pumping beam, which depends sensitively on the atomic density of the alkali metal. We present a novel scheme to determine atomic density based on zero-field magnetic resonance. The resonance linewidth under different transverse DC magnetic fields is fitted by means of a quadratic function. The atomic density can be extracted from the quadratic coefficients of the fitted function. The experimental results indicate that the deviation of measured density is less than two times compared with the theoretical values between 378 K and 403 K. Furthermore, the influence of modulation field on resonance linewidth is investigated experimentally and theoretically. A miniature single-beam SERF atomic magnetometer with a sensor head volume of only 16.2 cm 3 and the measuring sensitivity of 40 fT/ Hz 1/2 has been achieved. These results should be beneficial for guiding the development of a chip-scale atomic magnetometer with high sensitivity and spatial resolution for bio-magnetic field imaging applications.
We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about 400 pG/Hz400\text{ }\text{pG}/\sqrt{\text{Hz}}400 pG/Hz​. Based on photon shot noise, we project a sensitivity of 40 pG/Hz40\text{ }\text{pG}/\sqrt{\text{Hz}}40 pG/Hz​. A theoretical optimization of the magnetometer indicates sensitivities on the order of 2 pG/Hz2\text{ }\text{pG}/\sqrt{\text{Hz}}2 pG/Hz​ should be achievable in a 1 cm31\text{ }{\text{cm}}^{3}1 cm3 volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.