Conference on Precision Electromagnetic Measurements

A Josephson Arbitrary Waveform Synthesizer with Ultra-Short Cables Optimized for Operations of up to 2 MHz

Rinis Ferizaj, Stephan Bauer, Ralf Behr, Oliver Kieler

Published Sep 1, 2026• 0 citations
Publisher

Abstract

Quantum AC voltage standards are important for AC voltage and impedance metrology. Current experiments show that pulse-driven Josephson Arbitrary Waveform Synthesizers (JAWS) are used in metrological applications with low uncertainties up to about 500 kHz. Higher frequencies are limited by dispersion, attenuation, and impedance mismatch in long cryostat wiring, effects that scale approximately with the square of the cable length. To circumvent these limitations, we set up a JAWS setup in a special cryocooler, significantly reducing cable lengths.

DOI
10.1109/cpem68396.2026.11756923

Related papers

Development and Applications of a Four-Volt Josephson Arbitrary Waveform Synthesizer

Nathan E. Flowers-Jacobs, Alain Rüfenacht, Anna E. Fox +5 more

We have recently created a 4 V rms cryocooled JAWS (Josephson Arbitrary Waveform Synthesizer) using 204,960 nearly identical Josephson junctions (JJs) that are embedded in coplanar-wave guides. The JJs are pulse-biased at repetition rates up to 16×109pulses per second to create quantum-accurate, calculable AC waveforms at frequencies from DC to greater than 1 MHz. This system has metrological applications including in precision ac voltage calibrations, comparisons of arbitrary impedances, and ac power measurements.

IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2019•18 citations

Josephson-based quantum voltage standards – an ongoing success story

Ralf Behr, Stephan Bauer, Marco Kraus +2 more

The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.

•Jan 1, 2025•0 citations

Cryocooler Operation of a Pulse-Driven AC Josephson Voltage Standard at PTB

Oliver Kieler, Thomas Scheller, J. Kohlmann

The PTB Josephson Arbitrary Waveform Synthesizer (JAWS) enables the generation of arbitrary waveforms up to voltages of 70 mVRMS (199 mVPP) using two Josephson arrays in series containing 4000 Josephson junctions each. The SNS-like double-stacked junctions are based on NbxSi1-x as barrier material. While the JAWS system is typically operated using a Dewar with liquid helium, the operation in a closed-cycle pulse-tube cryocooler at temperatures around 4.2 K range was here investigated and successfully demonstrated. For this purpose a special designed cryoprobe was used to provide high quality pulses to the Josephson arrays.

World Journal of Condensed Matter Physics•Jan 1, 2013•28 citations

Development of josephson arbitrary waveform synthesizer at physikalisch-Technische bundesanstalt (PTB)

Oliver Kieler

This paper presents the basic principle of the pulse-driven ac Josephson voltage standard, also called “Josephson arbitrary waveform synthesizer” (JAWS). We will mainly focus on activities and developments at the Physikalisch-Technische Bundesanstalt (PTB). The JAWS is suitable to generate high precision quantized waveforms, which can be arbitrarily programmed in the frequency and time domain with extremely high spectral purity (typical signal-to-noise ratios SNR of 120–140 dBc). A brief overview of the fabrication technology for highly integrated JAWS circuits with more than 50 000 junctions per chip will be described. This includes the stacked junction technology with up to 5-stacked junctions. The experimental setup and the key-features of JAWS will be shown too. New approaches designed to further increase the output voltage, to simplify the experimental setup, and to extend the range of applications are the on-chip power dividers, the optical pulse drive, and the RF-JAWS. A selected application of the JAWS is described to demonstrate the usability of sophisticated JAWS waveforms for the complex characterization of electrical devices. The PTB JAWS circuits already have a significant impact on the quantum ac voltage metrology community. JAWS chips made at PTB have been distributed to more than 10 national metrology and other research institutes within the framework of international research projects.

Low Temperature Physics•Nov 1, 2024•10 citations

Optical pulse-drive and on-chip power splitter for the pulse-driven AC Josephson Voltage Standard

Oliver Kieler, Hao Tian, Rolf-Werner Gerdau +11 more

The pulse-driven Josephson Voltage Standard, also called Josephson Arbitrary Waveform Synthesizer (JAWS) is already well established for different applications in AC voltage metrology. To further increase the output voltage towards 10 V and to reduce the complexity of the JAWS systems we investigated two different approaches, which finally can be combined. One approach is to integrate an optimized on-chip power splitter to reduce the number of high-frequency (HF) channels from room temperature down to 4 K. A pulse pattern generator with less HF outputs will directly reduce the complexity and costs of a JAWS system. The second approach is to use an optical pulse-drive implementing cold photodiodes close to the JAWS chip. The use of optical fiber will have two main advantages: the optical fibers will reduce the high frequency noise and will enable an easy splitting into parallel optical channels. We will present first results with both approaches.

IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2019•0 citations

VHF Josephson Arbitrary Waveform Synthesizer

Jeremy N. Thomas, Nathan E. Flowers-Jacobs, Anna E. Fox +3 more

We report on the design, fabrication, and measurement of a very high frequency band Josephson arbitrary waveform synthesizer (VHF-JAWS) at frequencies from 1 kHz to 50.05 MHz. The VHF-JAWS chip is composed of a series array of 12 810 Josephson junctions (JJs) embedded in a superconducting coplanar waveguide. Each JJ responds to a pattern of current pulses by creating a corresponding pattern of voltage pulses, each with a time-integrated area related to fundamental constants as${{h/2e}}$. The pulse patterns are chosen to produce quantum-based single-tone voltage waveforms with an open-circuit voltage of 50 mV rms (–19.03 dBm output power into 50$\Omega$load impedances) at frequencies up to 50.05 MHz, which is more than twice the voltage that has been generated by previous RF-JAWS designs at 1 GHz. The VHF-JAWS is “quantum-locked,” that is, it generates one quantized output voltage pulse per input current pulse per JJ while varying the dc current through the JJ array by at least 0.4 mA and the amplitude of the bias pulses by at least 10 %. We use the large bias pulse quantum-locking range to investigate one source of error in detail: the direct feedthrough of the current bias pulses into the DUT at VHF frequencies, which adds an unwanted, in-band component to the measured voltage. We reduce this error by high-pass filtering the current bias pulses and measure the error as a function of input pulse amplitude using two techniques: 1) by measuring small changes over the quantum-locking range and 2) by passively attenuating the input pulse amplitude so that the nonlinear JJs no longer generate voltage pulses while the error is only linearly scaled.

IEEE Transactions on Applied Superconductivity•Jul 1, 2024•11 citations
Quantum AC voltage standards are important for AC voltage and impedance metrology. Current experiments show that pulse-driven Josephson Arbitrary Waveform Synthesizers (JAWS) are used in metrological applications with low uncertainties up to about 500 kHz. Higher frequencies are limited by dispersion, attenuation, and impedance mismatch in long cryostat wiring, effects that scale approximately with the square of the cable length. To circumvent these limitations, we set up a JAWS setup in a special cryocooler, significantly reducing cable lengths.
We have recently created a 4 V rms cryocooled JAWS (Josephson Arbitrary Waveform Synthesizer) using 204,960 nearly identical Josephson junctions (JJs) that are embedded in coplanar-wave guides. The JJs are pulse-biased at repetition rates up to 16×109pulses per second to create quantum-accurate, calculable AC waveforms at frequencies from DC to greater than 1 MHz. This system has metrological applications including in precision ac voltage calibrations, comparisons of arbitrary impedances, and ac power measurements.
The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.
The PTB Josephson Arbitrary Waveform Synthesizer (JAWS) enables the generation of arbitrary waveforms up to voltages of 70 mVRMS (199 mVPP) using two Josephson arrays in series containing 4000 Josephson junctions each. The SNS-like double-stacked junctions are based on NbxSi1-x as barrier material. While the JAWS system is typically operated using a Dewar with liquid helium, the operation in a closed-cycle pulse-tube cryocooler at temperatures around 4.2 K range was here investigated and successfully demonstrated. For this purpose a special designed cryoprobe was used to provide high quality pulses to the Josephson arrays.
This paper presents the basic principle of the pulse-driven ac Josephson voltage standard, also called “Josephson arbitrary waveform synthesizer” (JAWS). We will mainly focus on activities and developments at the Physikalisch-Technische Bundesanstalt (PTB). The JAWS is suitable to generate high precision quantized waveforms, which can be arbitrarily programmed in the frequency and time domain with extremely high spectral purity (typical signal-to-noise ratios SNR of 120–140 dBc). A brief overview of the fabrication technology for highly integrated JAWS circuits with more than 50 000 junctions per chip will be described. This includes the stacked junction technology with up to 5-stacked junctions. The experimental setup and the key-features of JAWS will be shown too. New approaches designed to further increase the output voltage, to simplify the experimental setup, and to extend the range of applications are the on-chip power dividers, the optical pulse drive, and the RF-JAWS. A selected application of the JAWS is described to demonstrate the usability of sophisticated JAWS waveforms for the complex characterization of electrical devices. The PTB JAWS circuits already have a significant impact on the quantum ac voltage metrology community. JAWS chips made at PTB have been distributed to more than 10 national metrology and other research institutes within the framework of international research projects.
The pulse-driven Josephson Voltage Standard, also called Josephson Arbitrary Waveform Synthesizer (JAWS) is already well established for different applications in AC voltage metrology. To further increase the output voltage towards 10 V and to reduce the complexity of the JAWS systems we investigated two different approaches, which finally can be combined. One approach is to integrate an optimized on-chip power splitter to reduce the number of high-frequency (HF) channels from room temperature down to 4 K. A pulse pattern generator with less HF outputs will directly reduce the complexity and costs of a JAWS system. The second approach is to use an optical pulse-drive implementing cold photodiodes close to the JAWS chip. The use of optical fiber will have two main advantages: the optical fibers will reduce the high frequency noise and will enable an easy splitting into parallel optical channels. We will present first results with both approaches.
We report on the design, fabrication, and measurement of a very high frequency band Josephson arbitrary waveform synthesizer (VHF-JAWS) at frequencies from 1 kHz to 50.05 MHz. The VHF-JAWS chip is composed of a series array of 12 810 Josephson junctions (JJs) embedded in a superconducting coplanar waveguide. Each JJ responds to a pattern of current pulses by creating a corresponding pattern of voltage pulses, each with a time-integrated area related to fundamental constants ash/2e{{h/2e}}h/2e. The pulse patterns are chosen to produce quantum-based single-tone voltage waveforms with an open-circuit voltage of 50 mV rms (–19.03 dBm output power into 50Ω\OmegaΩload impedances) at frequencies up to 50.05 MHz, which is more than twice the voltage that has been generated by previous RF-JAWS designs at 1 GHz. The VHF-JAWS is “quantum-locked,” that is, it generates one quantized output voltage pulse per input current pulse per JJ while varying the dc current through the JJ array by at least 0.4 mA and the amplitude of the bias pulses by at least 10 %. We use the large bias pulse quantum-locking range to investigate one source of error in detail: the direct feedthrough of the current bias pulses into the DUT at VHF frequencies, which adds an unwanted, in-band component to the measured voltage. We reduce this error by high-pass filtering the current bias pulses and measure the error as a function of input pulse amplitude using two techniques: 1) by measuring small changes over the quantum-locking range and 2) by passively attenuating the input pulse amplitude so that the nonlinear JJs no longer generate voltage pulses while the error is only linearly scaled.