Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Conference on Advanced Semiconductor Devices and Integration Technology (ASDIT)

Research on High-Precision Quantum Voltage System Based on Programmable Josephson Junction Array

Yi Wang, Weizhen Ma, Li Wang

Published Aug 1, 2026• 0 citations
Publisher
DOI
10.1109/asdit71786.2026.11737281

Related papers

Establishing Programmable Josephson Voltage Standard and Maintaining Its Quantum Accuracy

TÜBİTAK Ulusal Metroloji Enstitüsü, P.K. 54, 41470, Gebze-Kocaeli, Turkey, Tezgül Coşkun Öztürk, Sarp Ertürk +4 more

International Journal of Electrical and Electronic Engineering & Telecommunications•Jan 1, 2019•6 citations

A Quantum-Traceable Harmonic Power Standard Leveraging a Nano-Fabricated Programmable Josephson Junction Array

Feng Shan Pan, Yuyao Yang, Lihua Zhong +3 more

The advancement of quantum metrology is intrinsically linked to the development of nanoelectronic and quantum devices. The Programmable Josephson Voltage Standard (PJVS), a system comprising thousands of superconducting Josephson junctions with tunnel barriers on the nanoscale, provides a fundamental quantum-based AC voltage reference. However, extending this quantum traceability to harmonic power measurements, essential for modern power systems with extensive power electronics, remains a significant challenge. This work demonstrates a high-accuracy harmonic power standard by leveraging the unique quantum properties of a nano-fabricated PJVS array. We introduce a time-division calibration scheme where the precise voltage steps of the PJVS are used to calibrate a high-performance dual-channel analog-to-digital converter (ADC). This method bypasses the need for complex synchronous sampling and heavy computational algorithms, relying instead on the intrinsic accuracy of the Josephson quantum voltage. The system achieves a measurement uncertainty of 14 × 10 ×6 ( k = 2) for fundamental power and 50 × 10 −6 ( k = 2) for harmonic power up to the 60th order. Comparative tests with national primary standards show a maximum deviation of only 6 × 10 −6 for harmonic power metrology but also serves as a compelling demonstration of a practical, high-precision application for superconducting nanoelectronic devices, bridging the gap between quantum standards and industrial measurement needs.

Journal of Nanoelectronics and Optoelectronics•Sep 1, 2025•0 citations

Quantum manipulation and simulation using Josephson junction arrays

Xingxiang Zhou, Ari Mizel

arXiv:quant-ph/0605016•Physica C Superconductivity•Sep 7, 2005•2 citations

Highly precise comparison of Nb/Al/AlOx/Al/AlOx/Al/Nb Josephson junction arrays using a SQUID as a null detector

I. Ya. Krasnopolin, Ralf Behr, J. Niemeyer

A direct comparison of two voltages at 0.6 V reproduced by programmable arrays with Nb/Al/AlOx/Al/AlOx/Al/Nb Josephson junctions was carried out using a SQUID as a null detector. The voltage difference was measured and found to be smaller than 1.2 × 10−17 V. Jumps of the current in the flux transformer loop can be attributed to phase-slipping events when the phase lock in the arrays is broken.

Superconductor Science and Technology•May 22, 2002•18 citations

Josephson Junctions for Programmable and AC Quantum Voltmeters

V. Lacquaniti, Domenico Andreone, Sabino Maggi +4 more

•Jan 1, 2007•0 citations

Josephson-based quantum voltage standards – an ongoing success story

Ralf Behr, Stephan Bauer, Marco Kraus +2 more

The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.

•Jan 1, 2025•0 citations
The advancement of quantum metrology is intrinsically linked to the development of nanoelectronic and quantum devices. The Programmable Josephson Voltage Standard (PJVS), a system comprising thousands of superconducting Josephson junctions with tunnel barriers on the nanoscale, provides a fundamental quantum-based AC voltage reference. However, extending this quantum traceability to harmonic power measurements, essential for modern power systems with extensive power electronics, remains a significant challenge. This work demonstrates a high-accuracy harmonic power standard by leveraging the unique quantum properties of a nano-fabricated PJVS array. We introduce a time-division calibration scheme where the precise voltage steps of the PJVS are used to calibrate a high-performance dual-channel analog-to-digital converter (ADC). This method bypasses the need for complex synchronous sampling and heavy computational algorithms, relying instead on the intrinsic accuracy of the Josephson quantum voltage. The system achieves a measurement uncertainty of 14 × 10 ×6 ( k = 2) for fundamental power and 50 × 10 −6 ( k = 2) for harmonic power up to the 60th order. Comparative tests with national primary standards show a maximum deviation of only 6 × 10 −6 for harmonic power metrology but also serves as a compelling demonstration of a practical, high-precision application for superconducting nanoelectronic devices, bridging the gap between quantum standards and industrial measurement needs.
The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.