Establishing Programmable Josephson Voltage Standard and Maintaining Its Quantum Accuracy

TÜBİTAK Ulusal Metroloji Enstitüsü, P.K. 54, 41470, Gebze-Kocaeli, Turkey, Tezgül Coşkun Öztürk, Sarp Ertürk, Ali Tangel, Adem Gedik, Mesut Yoğun, Murat Celep

Published Jan 1, 2019• 6 citations
Publisher
DOI
10.18178/ijeetc.8.1.19-25

Related papers

A new way to realize a programmable Josephson voltage standard

Juha Hassel, Heikki Seppä, M. Kiviranta

Physica B Condensed Matter•Jul 1, 2000•4 citations

Cryocooled 10 V Programmable Josephson Voltage Standard

Alain Rüfenacht, Logan A. Howe, Anna E. Fox +4 more

The two main challenges to operating a programmable Josephson voltage standard (PJVS) on a cryocooler are the available cooling power and the temperature oscillations of the cold head. We overcame these challenges and successfully operated a PJVS circuit on a cryocooler by employing one supercritical helium buffer that damps the temperature oscillations, developing a new cryogenic package that increases the thermal conductivity between the chip and the cold head, and increasing overall device performance with fabrication improvements. A 1.32 mA step width of the quantized voltage produced with all of the subarrays of the PJVS circuit biased was achieved at an operating temperature of 4.3 K. The quantum accuracy of the PJVS is maintained at temperatures up to 4.8 K. This result was obtained with a cryocooler that employs a 3 kW water-cooled compressor to produce at the chip about 270 mW of net cooling power at 4.3 K.

IEEE Transactions on Instrumentation and Measurement•Dec 11, 2014•35 citations

Research on High-Precision Quantum Voltage System Based on Programmable Josephson Junction Array

Yi Wang, Weizhen Ma, Li Wang

International Conference on Advanced Semiconductor Devices and Integration Technology (ASDIT)•Aug 1, 2026•0 citations

ac-Josephson-Effect Determination of e h : A Standard of Electrochemical Potential Based on Macroscopic Quantum Phase Coherence in Superconductors

Thomas F. Finnegan, Arnold M. Denenstein, D. N. Langenberg

An ac-Josephson-effect determination of $\frac{e}{h}$ with significantly improved accuracy is reported. The precision of the measurement is determined by uncertainties associated with the comparison of a Josephson-device voltage with the emf of an electrochemical-standard-cell voltage reference and is about 3 parts in ${10}^{8}$. This precision was made possible by use of Josephson devices at voltages above 10 mV and design and construction of two special voltage-comparator instruments. The fabrication and operation of the Josephson devices and the design and performance of the voltage comparators are discussed. The 3/${10}^{8}$ precision represents the precision with which a drift-free and readily reproducible Josephson voltage standard can be realized in practice using the techniques developed for these experiments. The accuracy of the final result is about 12 parts in ${10}^{8}$ and is determined primarily by uncertainties associated with the stability of the local electrochemical voltage standard and with establishment of the relationship between the local volt and the volt maintained by the U. S. National Bureau of Standards. Significant improvements in the maintenance of the local-voltage standard which contributed to reduction of the final uncertainty to this value are discussed. During the course of the experiments, the Josephson frequency-voltage relation was shown experimentally to be independent of magnetic field, temperature, and Josephson-device bias voltage or induced step number to within the accuracy of the final result. The final experimental result and its one-standard-deviation uncertainty are $\frac{2e}{h}=(483.593718\ifmmode\pm\else\textpm\fi{}0.000060)\frac{\mathrm{MHz}}{\ensuremath{\mu}{V}_{\mathrm{NBS}69}}$ (0.12 ppm) referred to the volt as maintained by the U. S. National Bureau of Standards after January 1, 1969. This result is in excellent agreement with the earlier, less accurate result of Parker, Langenberg, Denenstein, and Taylor, which played an important role in the 1969 adjustment of the fundamental physical constants by Taylor, Parker, and Langenberg. It is in reasonable agreement with values recently reported by several other groups. The significantly improved accuracy of the present result makes possible a small improvement in the accuracy of the derived value of the fine structure constant and clears the way for a larger improvement through more accurate determination of the proton gyromagnetic ratio.

Physical review. B, Solid state•Sep 1, 1971•66 citations

Maximizing the Resolution of a Dual RF Drive Programmable Josephson Voltage Standard

D. Georgakopoulos

A dual radio frequency drive programmable Josephson voltage standard can generate quasi-continuous voltages with quantum accuracy. This paper focuses on the mathematical methods used to maximize the achievable voltage resolution and describes two algorithms that can be employed. Quasi-continuous voltages with a resolution of a few nanovolts have been achieved using Josephson junction arrays with missing junctions and an almost arbitrary segment structure.

IEEE Transactions on Instrumentation and Measurement•Mar 4, 2015•4 citations

Principles of Josephson-Junction-Based Quantum Computation

Serhii E. Shafranjuk, John B. Ketterson

Springer eBooks•Jan 1, 2008•2 citations
The two main challenges to operating a programmable Josephson voltage standard (PJVS) on a cryocooler are the available cooling power and the temperature oscillations of the cold head. We overcame these challenges and successfully operated a PJVS circuit on a cryocooler by employing one supercritical helium buffer that damps the temperature oscillations, developing a new cryogenic package that increases the thermal conductivity between the chip and the cold head, and increasing overall device performance with fabrication improvements. A 1.32 mA step width of the quantized voltage produced with all of the subarrays of the PJVS circuit biased was achieved at an operating temperature of 4.3 K. The quantum accuracy of the PJVS is maintained at temperatures up to 4.8 K. This result was obtained with a cryocooler that employs a 3 kW water-cooled compressor to produce at the chip about 270 mW of net cooling power at 4.3 K.
An ac-Josephson-effect determination of eh\frac{e}{h}he​ with significantly improved accuracy is reported. The precision of the measurement is determined by uncertainties associated with the comparison of a Josephson-device voltage with the emf of an electrochemical-standard-cell voltage reference and is about 3 parts in 108{10}^{8}108. This precision was made possible by use of Josephson devices at voltages above 10 mV and design and construction of two special voltage-comparator instruments. The fabrication and operation of the Josephson devices and the design and performance of the voltage comparators are discussed. The 3/108{10}^{8}108 precision represents the precision with which a drift-free and readily reproducible Josephson voltage standard can be realized in practice using the techniques developed for these experiments. The accuracy of the final result is about 12 parts in 108{10}^{8}108 and is determined primarily by uncertainties associated with the stability of the local electrochemical voltage standard and with establishment of the relationship between the local volt and the volt maintained by the U. S. National Bureau of Standards. Significant improvements in the maintenance of the local-voltage standard which contributed to reduction of the final uncertainty to this value are discussed. During the course of the experiments, the Josephson frequency-voltage relation was shown experimentally to be independent of magnetic field, temperature, and Josephson-device bias voltage or induced step number to within the accuracy of the final result. The final experimental result and its one-standard-deviation uncertainty are $\frac{2e}{h}=(483.593718\ifmmode\pm\else\textpm\fi{}0.000060)\frac{\mathrm{MHz}}{\ensuremath{\mu}{V}_{\mathrm{NBS}69}}$ (0.12 ppm) referred to the volt as maintained by the U. S. National Bureau of Standards after January 1, 1969. This result is in excellent agreement with the earlier, less accurate result of Parker, Langenberg, Denenstein, and Taylor, which played an important role in the 1969 adjustment of the fundamental physical constants by Taylor, Parker, and Langenberg. It is in reasonable agreement with values recently reported by several other groups. The significantly improved accuracy of the present result makes possible a small improvement in the accuracy of the derived value of the fine structure constant and clears the way for a larger improvement through more accurate determination of the proton gyromagnetic ratio.