Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Applied

Fine-structure transfer as a fluorescence readout channel in optically pumped magnetometers

Wanqing Li, Wei Li, Jiaxin Liu

Published Nov 5, 2026• 0 citations
Publisher

Abstract

Signal readout in optically pumped magnetometers (OPMs) is usually described in terms of ground-state spin polarization and its Larmor response, while excited-state fine-structure transfer (FST) is absorbed into effective relaxation terms. Here, we treat collision-mediated FST as a fluorescence readout channel under OPM operating conditions. Using steady-state fluorescence spectroscopy, low-frequency magnetic-field modulation, and temperature-dependent Rb-He measurements, we observe collision-generated D2 fluorescence under single-wavelength D1 pumping without direct D2 excitation. The D1 signal is dominated by the modulation frequency ${\mathrm{\ensuremath{\Omega}}}_{m}$, whereas the D2 signal contains a pronounced $2{\mathrm{\ensuremath{\Omega}}}_{m}$ component whose amplitude scales quadratically with the modulation-field amplitude. Unpolarized D2 fluorescence from the ${P}_{3/2}$ level carries a rank-2 alignment term that D1 fluorescence from the ${P}_{1/2}$ level lacks. This selection rule, the $2{\mathrm{\ensuremath{\Omega}}}_{m}$ dominance, and the quadratic scaling together identify the D2 channel as a rank-2-weighted readout opened by FST. From the temperature dependence of the $\mathrm{D}2/\mathrm{D}1$ fluorescence ratio, we obtain an effective Rb-He FST cross section ${\ensuremath{\sigma}}_{\mathrm{eff}}=(2.7\ifmmode\pm\else\textpm\fi{}0.1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}\text{ }{\mathrm{cm}}^{2}$ under an effective symmetric-mixing approximation, consistent with reported Rb-He FST values. The same collision conditions occur in spin-exchange-relaxation-free (SERF) magnetometers, NMR gyroscopes, and spin-exchange optical-pumping cells, where FST affects fluorescence readout and optical-pumping models.

DOI
10.1103/x996-xl38

Related papers

Spin projection noise and the magnetic sensitivity of optically pumped magnetometers

K. Mouloudakis, V. Koutrouli, Iannis K. Kominis +2 more

Present protocols for obtaining the ultimate magnetic sensitivity of optically pumped magnetometers (OPMs) utilizing alkali-metal ensembles rely on uncorrelated atoms in stretched states. A new approach for calculating the spin projection noise (SPN)-limited signal to noise ratio (SNR) and the magnetic sensitivity of OPMs is proposed. Our model is based solely on the mean-field density matrix dynamics and in contrast to previous models, it applies to both low and high field regimes, it takes into account the degree of spin polarization, the intra- and interhyperfine correlations, the decoherence processes, the atom-light coupling and the effects of the spin dynamics on the spin-noise spectra. Fine tuning of the probe frequency allow us to explore different hyperfine states and ground-state correlations. Especially in the spin-exchange-relaxation-free (SERF) regime, alongside the magnetic resonance narrowing and the increased number density, hallmarks of SERF magnetometers, we report on a new SERF feature; the reduction of spin-projection noise at the spin precession frequency as a consequence of strongly-correlated hyperfine spins that attenuate and redistribute SPN when properly probed.

arXiv:2402.10746•Feb 16, 2024•2 citations

Magnetic Field Compensation for An Optically Pumped Magnetometer Without Iteration

Yaqiong Niu, Chaofeng Ye

The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...•Oct 29, 2023•1 citation

Analysis of effects of magnetic field gradient on atomic spin polarization and relaxation in optically pumped atomic magnetometers

Xiujie Fang, Kai Wei, Yueyang Zhai +6 more

The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.

Optics Express•Jan 21, 2022•64 citations

Optically Pumped Magnetometer and Its Application

Jixi Lu, Yao Chen

The optically pumped magnetometer (OPM) is a class of atomic devices that rely on the measurement of Larmor precession of an atomic spin ensemble in a magnetic field. They need the specific frequency light to complete the pumping and detection process. OPMs typically work under the Earth's magnetic field or a limited field. When operating in near-zero field, they can realize the spin-exchange relaxation-free (SERF) regime, thereby promoting a substantial increase in sensitivity. At present, OPMs have been widely used in magnetoencephalography, magnetocardiography, geomagnetic detection, and inertia measurement (comagnetometer). There are a large number of researchers engaged in the study of relevant mechanisms, devices, technologies, and applications. More importantly, supported by MEMS technology and micro/nano optics, OPMs have the potential to move toward chip-scale sensors. This special issue contains some latest developments in OPMs and related areas. We hope the reprint can provide valuable references for researchers in the related field.

MDPI eBooks•Jul 31, 2025•0 citations

82D3/2 ↔ 82D5/2 excitation transfer in rubidium induced in collisions with ground-state Rb atoms

Małgorzata Głódź, J. B. Atkinson, L. Krause

Cross sections for inelastic transfer between the 82D3/2 and 82D5/2 fine-structure states in rubidium, induced in resonant collisions with ground-state Rb atoms, have been determined using an experimental method involving two-photon excitation of atomic fluorescence. Rubidium vapor in a fluorescence cell was irradiated with pulses of 641 nm radiation from a N2 laser-pumped dye-laser tuned to excite one of the 82D states. The resulting fluorescence included the direct component originating from the optically excited state and a sensitized component arising from the other fine-structure state populated by collisions. Relative intensities of the fluorescent components, determined by photon-counting techniques, yielded the cross sections for excitation transfer: Q(2D3/2 → 2D5/2) = 8.1 × 10−13 cm2; Q(2D3/2 ← 2D5/2) = 5.5 × 1013 cm2; as well as [Formula: see text], the effective quenching cross section. The excitation transfer cross sections which are considered accurate to within ±20% are in the ratio predicted by the principle of detailed balancing.

Canadian Journal of Physics•Apr 1, 1981•8 citations

An optically modulated zero-field atomic magnetometer with suppressed spin-exchange broadening

Ricardo Jiménez-Martínez, Svenja A. Knappe, John E. Kitching

We demonstrate an optically pumped (87)Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the (87)Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-based magnetometers where radio frequency magnetic fields can induce cross-talk among adjacent sensors or affect the source of the magnetic field being measured.

arXiv:1404.0374•Review of Scientific Instruments•Apr 1, 2014•49 citations
Signal readout in optically pumped magnetometers (OPMs) is usually described in terms of ground-state spin polarization and its Larmor response, while excited-state fine-structure transfer (FST) is absorbed into effective relaxation terms. Here, we treat collision-mediated FST as a fluorescence readout channel under OPM operating conditions. Using steady-state fluorescence spectroscopy, low-frequency magnetic-field modulation, and temperature-dependent Rb-He measurements, we observe collision-generated D2 fluorescence under single-wavelength D1 pumping without direct D2 excitation. The D1 signal is dominated by the modulation frequency \ensuremathΩm{\mathrm{\ensuremath{\Omega}}}_{m}\ensuremathΩm​, whereas the D2 signal contains a pronounced 2\ensuremathΩm2{\mathrm{\ensuremath{\Omega}}}_{m}2\ensuremathΩm​ component whose amplitude scales quadratically with the modulation-field amplitude. Unpolarized D2 fluorescence from the P3/2{P}_{3/2}P3/2​ level carries a rank-2 alignment term that D1 fluorescence from the P1/2{P}_{1/2}P1/2​ level lacks. This selection rule, the 2\ensuremathΩm2{\mathrm{\ensuremath{\Omega}}}_{m}2\ensuremathΩm​ dominance, and the quadratic scaling together identify the D2 channel as a rank-2-weighted readout opened by FST. From the temperature dependence of the D2/D1\mathrm{D}2/\mathrm{D}1D2/D1 fluorescence ratio, we obtain an effective Rb-He FST cross section \ensuremathσeff=(2.7\ifmmode±\else\textpm\fi0.1)\ifmmode×\else\texttimes\fi10\ensuremath−17 cm2{\ensuremath{\sigma}}_{\mathrm{eff}}=(2.7\ifmmode\pm\else\textpm\fi{}0.1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}\text{ }{\mathrm{cm}}^{2}\ensuremathσeff​=(2.7\ifmmode±\else\textpm\fi0.1)\ifmmode×\else\texttimes\fi10\ensuremath−17 cm2 under an effective symmetric-mixing approximation, consistent with reported Rb-He FST values. The same collision conditions occur in spin-exchange-relaxation-free (SERF) magnetometers, NMR gyroscopes, and spin-exchange optical-pumping cells, where FST affects fluorescence readout and optical-pumping models.
Present protocols for obtaining the ultimate magnetic sensitivity of optically pumped magnetometers (OPMs) utilizing alkali-metal ensembles rely on uncorrelated atoms in stretched states. A new approach for calculating the spin projection noise (SPN)-limited signal to noise ratio (SNR) and the magnetic sensitivity of OPMs is proposed. Our model is based solely on the mean-field density matrix dynamics and in contrast to previous models, it applies to both low and high field regimes, it takes into account the degree of spin polarization, the intra- and interhyperfine correlations, the decoherence processes, the atom-light coupling and the effects of the spin dynamics on the spin-noise spectra. Fine tuning of the probe frequency allow us to explore different hyperfine states and ground-state correlations. Especially in the spin-exchange-relaxation-free (SERF) regime, alongside the magnetic resonance narrowing and the increased number density, hallmarks of SERF magnetometers, we report on a new SERF feature; the reduction of spin-projection noise at the spin precession frequency as a consequence of strongly-correlated hyperfine spins that attenuate and redistribute SPN when properly probed.
The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.
The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.
The optically pumped magnetometer (OPM) is a class of atomic devices that rely on the measurement of Larmor precession of an atomic spin ensemble in a magnetic field. They need the specific frequency light to complete the pumping and detection process. OPMs typically work under the Earth's magnetic field or a limited field. When operating in near-zero field, they can realize the spin-exchange relaxation-free (SERF) regime, thereby promoting a substantial increase in sensitivity. At present, OPMs have been widely used in magnetoencephalography, magnetocardiography, geomagnetic detection, and inertia measurement (comagnetometer). There are a large number of researchers engaged in the study of relevant mechanisms, devices, technologies, and applications. More importantly, supported by MEMS technology and micro/nano optics, OPMs have the potential to move toward chip-scale sensors. This special issue contains some latest developments in OPMs and related areas. We hope the reprint can provide valuable references for researchers in the related field.
Cross sections for inelastic transfer between the 82D3/2 and 82D5/2 fine-structure states in rubidium, induced in resonant collisions with ground-state Rb atoms, have been determined using an experimental method involving two-photon excitation of atomic fluorescence. Rubidium vapor in a fluorescence cell was irradiated with pulses of 641 nm radiation from a N2 laser-pumped dye-laser tuned to excite one of the 82D states. The resulting fluorescence included the direct component originating from the optically excited state and a sensitized component arising from the other fine-structure state populated by collisions. Relative intensities of the fluorescent components, determined by photon-counting techniques, yielded the cross sections for excitation transfer: Q(2D3/2 → 2D5/2) = 8.1 × 10−13 cm2; Q(2D3/2 ← 2D5/2) = 5.5 × 1013 cm2; as well as [Formula: see text], the effective quenching cross section. The excitation transfer cross sections which are considered accurate to within ±20% are in the ratio predicted by the principle of detailed balancing.
We demonstrate an optically pumped (87)Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the (87)Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-based magnetometers where radio frequency magnetic fields can induce cross-talk among adjacent sensors or affect the source of the magnetic field being measured.