IEEE International Instrumentation and Measurement Technology Conference

SFE-ESO-Based Closed-Loop Strategy for Accurate MCG Measurement Using a SERF Atomic Magnetometer

Yuanbo Jin, Peiling Cui, Haifeng Zhang, Jiacheng Yao, Yutong Wei, Shiqiang Zheng

Published May 1, 2026• 0 citations
Publisher
DOI
10.1109/i2mtc66907.2026.11694555

Related papers

Comprehensive analysis of the magnetic field closed-loop control system in SERF atomic magnetometer

Le Jia, Xinda Song, Jianli Li +4 more

Sensors and Actuators A Physical•Jan 21, 2024•16 citations

Precision relaxation rate measurement in SERF atomic magnetometers through FoPSO algorithm

Gaoyi Lei, Yueyang Zhai, Yaxiang Wang +3 more

Measurement•Jul 29, 2025•2 citations

Light shift cross-sectional distribution measurement and suppression in SERF atomic magnetometers

Yuhao Wang, Ziqi Yuan, Shudong Lin +4 more

Measurement•Oct 15, 2025•2 citations

Accurate and fast measurement of alkali-metal and noble-gas atoms spin polarizability based on frequency response in SERF co-magnetometer

Xiujie Fang, Danyue Ma, Tian Zhao +4 more

Measurement•Sep 17, 2023•45 citations

A Performance-Enhanced Closed-Loop SERF Atomic Magnetometer

Ziao Liu, Jianli Li, Xiaoyu Li +3 more

The spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultrahigh sensitivity in ultraweak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF AM, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz$^{{1}/{2}}$in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.

IEEE Sensors Journal•Oct 1, 2024•5 citations

A Closed-Loop Model of the Single-Beam SERF Atomic Magnetometer

Ziao Liu, Jixi Lu, Xiaoyu Li +3 more

The bandwidth and dynamic range of spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) are effectively broadened by introducing magnetic field closed-loop control, rendering it a focal point in AM research. However, there is a deviation between the commonly used closed-loop AM model and the single-beam closed-loop AM experimentally constructed. In this study, we comprehensively analyzed each component in the actual system and proposed a closed-loop model of the single-beam SERF AM. The accuracy of the proposed model was varied through a comparative experiment with different control parameters. Based on comparative experiments, a tenfold reduction was verified in the mean square error of the proposed model compared with the commonly used closed-loop model. As an accurate model is essential for effective closed-loop control, the proposed closed-loop single-beam SERF AM model provides a theoretical foundation for the research and application of closed-loop AMs.

Academic Conference of China Instrument and Control Society (ACCIS)•Jul 28, 2024•0 citations
The spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultrahigh sensitivity in ultraweak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF AM, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz1/2^{{1}/{2}}1/2in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.
The bandwidth and dynamic range of spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) are effectively broadened by introducing magnetic field closed-loop control, rendering it a focal point in AM research. However, there is a deviation between the commonly used closed-loop AM model and the single-beam closed-loop AM experimentally constructed. In this study, we comprehensively analyzed each component in the actual system and proposed a closed-loop model of the single-beam SERF AM. The accuracy of the proposed model was varied through a comparative experiment with different control parameters. Based on comparative experiments, a tenfold reduction was verified in the mean square error of the proposed model compared with the commonly used closed-loop model. As an accurate model is essential for effective closed-loop control, the proposed closed-loop single-beam SERF AM model provides a theoretical foundation for the research and application of closed-loop AMs.