Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Robust control of an ensemble of NV centers in diamond under inhomogeneous fields for sensitive magnetometry

Takuya Kitamura

Published Jan 1, 2026• 0 citations
Publisher

Abstract

Quantum sensing with solid-state spins has attracted considerable attention following the development of single quantum systems. In particular, sub-picotesla level magnetometry has been demonstrated using negatively-charged nitrogen-vacancy (NV) centers in diamond by increasing the number of spins simultaneously employed for sensing. However, scaling up the number of spins inevitably introduces inhomogeneities in detuning and control field amplitudes across the ensemble system, which degrades the achievable sensitivity. Although several techniques, including pulsed dynamical decoupling and shaped pulses, have been studied to overcome such noises, they are not generally compatible with GHz-range AC magnetometry based on Rabi oscillations. This dissertation presents the development of an experimental platform and the demonstration of robust GHz-range AC magnetometry using a large ensemble of NV centers under inhomogeneous fields. Particular emphasis is placed on the effects of control-field amplitude inhomogeneity. To improve the homogeneity of the control field, barrel-shaped microwave forming systems are experimentally characterized, and their performance is compared with that of planar systems. Then, to mitigate detuning noise as well as control-field amplitude noise, concatenated continuous dynamical decoupling (CCDD) is applied to the inhomogeneous ensemble system, and the resulting dynamics are investigated with several initial states prepared with composite pulses. Finally, the CCDD sequence is applied for GHz-range AC magnetometry and compared with the conventional direct Rabi method. The results demonstrate that the robust dressed states generated by CCDD extend the lower bound of measurable amplitudes in GHz-range AC magnetometry.

DOI
10.18725/oparu-61147

Related papers

Robust gigahertz-range ac magnetometry with an ensemble of N − V centers in diamond using concatenated continuous dynamical decoupling

T. Kitamura, Genko T. Genov, Alon Salhov +5 more

Subpicotesla level magnetometry has been demonstrated using negatively charged nitrogen-vacancy ( N − V ) centers in diamond by increasing the number of spins simultaneously used for sensing in an N − V ensemble. However, such scale-up often introduces spatial inhomogeneities in detuning and control field amplitudes, which degrade sensitivity. Although several techniques have been utilized to overcome these challenges, including pulsed dynamical decoupling or shaped pulses, these are not generally compatible with the current state-of-the-art techniques for GHz-range ac magnetometry with N − V ensembles, which are typically based on Rabi oscillations. In this work, we experimentally demonstrate GHz-range ac magnetometry using a large ensemble of N − V centers under spatially inhomogeneous drive fields by employing concatenated continuous dynamical decoupling, which is designed for robustness against such imperfections. We compare its performance with the conventional direct Rabi method and show that the robust dressed states in our method extend significantly the measuring range to weaker signals in GHz-range ac magnetometry.

arXiv:2510.20401•Physical Review Applied•Jun 25, 2026•1 citation

GHz-range AC magnetometry with an ensemble of NV centers in diamond using concatenated continuous dynamical decoupling

T. Kitamura, G. Genov, Hitoshi Sumiya +3 more

we discuss GHz-range AC magnetometry by applying the CCDD sequence to a large ensemble of NV centers. Under the inhomogeneities in the detuning and the driving field, the direct Rabi method leads to a rapid decay of oscillations for weak signals, thereby limiting the lower bound of the measurable amplitude. Our experimental observation confirms that the microwave dressed states generated by the CCDD enable the measurement of weaker signals. These findings provide important insights into sensitive measurement of weak GHz-range AC magnetic fields under ensemble inhomogeneities.

•May 15, 2025•0 citations

Uniform microwave field formation for control of ensembles of negatively charged nitrogen vacancy in diamond

Oleg Rezinkin, Marina Rezinkina, Takuya Kitamura +2 more

The homogeneity of the microwave magnetic field is essential in controlling a large volume of ensemble spins, for example, in the case of sensitive magnetometry with nitrogen-vacancy (NV) centers in diamond. This is particularly important for pulsed measurement, where the fidelity of control pulses plays a crucial role in its sensitivity. So far, several magnetic field-forming systems have been proposed, but no detailed comparison has been made. Here, we numerically study the homogeneity of five different systems, including a planar antenna, a dielectric resonator, a cylindrical inductor, a barrel-shaped coil, and a nested barrel-shaped coil. The results of the simulation allowed us to optimize the design parameters of the barrel-shaped field-forming system, which led to significantly improved magnetic field uniformity. To measure this effect, we experimentally compared the homogeneity of a field-forming system having a barrel shape with that of a planar field-forming system by measuring Rabi oscillations of an ensemble of NV centers with them. Significant improvements in inhomogeneity were confirmed in the barrel-shaped coil.

quant-pharXiv:2605.13267•May 14, 2026

Room-temperature Composite-pulses for Robust Diamond Magnetometry

Jingyan Xu, Dong, Yang, Shao-Chun Zhang +6 more

The sensitivity of a practical quantum magnetometer is challenged by both inhomogeneous coupling between sensors and environment and errors in quantum control. Based on the physical criteria of modern quantum sensing, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening of sensor and control errors via optimized modulation of control field. Such a technique is verified on nitrogen-vacancy (NV) center in diamond to keep almost perfect operation up to a detuning as larger as $110\%$. The sensitivity of the magnetometer with NV center ensemble is experimentally improved by a factor of $4$, comparing to dynamical decoupling with normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in realistic systems. The used principle however, is universal and not restricted to NV center ensemble magnetometer.

arXiv:1811.00191•Nov 1, 2018•2 citations

Composite-pulse enhanced room-temperature diamond magnetometry

Yang Dong, Jingyan Xu, Shao-Chun Zhang +6 more

The sensitivity of practical solid quantum sensing can be boosted up by increasing the number of probes. However, the effects of spin dephasing caused by inhomogeneous broadening and imperfect quantum control can reduce the fidelity of quantum control and the sensitivity of quantum sensing with the dense ensemble of probes, such as nitrogen-vacancy (NV) centers in diamond. Here, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening and control errors via optimized modulation of the control field. Such a composite-pulse was verified on NV center to keep high fidelity quantum control up to a spectrum detuning as large as 110% of Rabi frequency. The sensitivity of the magnetometer with NV center ensemble was experimentally improved by a factor of 4, comparing to dynamical decoupling with a normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in practical applications. The used principle is universal and not restricted to NV center ensemble magnetometer.

Functional Diamond•Jan 2, 2021•8 citations

Optimized Dynamical Decoupling for Spin Ensembles with Large Inhomogeneities

Rajan Paul, Genko Genov, Oliver Schmid +4 more

Spin ensembles show increasing promise for highly efficient quantum sensing and quantum technologies. However, protecting their coherent properties remains a significant challenge. Dynamical decoupling (DD) typically employs a sequence of fast pulses that aim to reduce the effect of unwanted system-environment interactions. However, the performance of the DD sequences typically suffers in spin ensembles, e.g., due to amplitude and frequency inhomogeneities and control errors. In this work, we compare the performance of an extensive number of DD protocols for coherence protection and quantum sensing in an ensemble of negatively charged NV centers under ambient conditions. We identify the optimal approach that uses rapid adiabatic passage pulses, which are robust to amplitude and frequency inhomogeneity, in combination with the variation of their phases. We experimentally demonstrate an improved signal contrast and an order-of-magnitude increase in memory time with the optimal sequence compared to the widely used XY8 with standard rectangular pulses. We also apply our approach for improved sensing of a weak oscillating field. While our particular demonstration is with NV centers in diamond, the optimized protocol is generally applicable to other spin ensembles and to systems with high amplitude and/or frequency inhomogeneities.

quant-pharXiv:2610.39693•Oct 30, 2026•0 citations
Quantum sensing with solid-state spins has attracted considerable attention following the development of single quantum systems. In particular, sub-picotesla level magnetometry has been demonstrated using negatively-charged nitrogen-vacancy (NV) centers in diamond by increasing the number of spins simultaneously employed for sensing. However, scaling up the number of spins inevitably introduces inhomogeneities in detuning and control field amplitudes across the ensemble system, which degrades the achievable sensitivity. Although several techniques, including pulsed dynamical decoupling and shaped pulses, have been studied to overcome such noises, they are not generally compatible with GHz-range AC magnetometry based on Rabi oscillations. This dissertation presents the development of an experimental platform and the demonstration of robust GHz-range AC magnetometry using a large ensemble of NV centers under inhomogeneous fields. Particular emphasis is placed on the effects of control-field amplitude inhomogeneity. To improve the homogeneity of the control field, barrel-shaped microwave forming systems are experimentally characterized, and their performance is compared with that of planar systems. Then, to mitigate detuning noise as well as control-field amplitude noise, concatenated continuous dynamical decoupling (CCDD) is applied to the inhomogeneous ensemble system, and the resulting dynamics are investigated with several initial states prepared with composite pulses. Finally, the CCDD sequence is applied for GHz-range AC magnetometry and compared with the conventional direct Rabi method. The results demonstrate that the robust dressed states generated by CCDD extend the lower bound of measurable amplitudes in GHz-range AC magnetometry.
Subpicotesla level magnetometry has been demonstrated using negatively charged nitrogen-vacancy ( N − V ) centers in diamond by increasing the number of spins simultaneously used for sensing in an N − V ensemble. However, such scale-up often introduces spatial inhomogeneities in detuning and control field amplitudes, which degrade sensitivity. Although several techniques have been utilized to overcome these challenges, including pulsed dynamical decoupling or shaped pulses, these are not generally compatible with the current state-of-the-art techniques for GHz-range ac magnetometry with N − V ensembles, which are typically based on Rabi oscillations. In this work, we experimentally demonstrate GHz-range ac magnetometry using a large ensemble of N − V centers under spatially inhomogeneous drive fields by employing concatenated continuous dynamical decoupling, which is designed for robustness against such imperfections. We compare its performance with the conventional direct Rabi method and show that the robust dressed states in our method extend significantly the measuring range to weaker signals in GHz-range ac magnetometry.
we discuss GHz-range AC magnetometry by applying the CCDD sequence to a large ensemble of NV centers. Under the inhomogeneities in the detuning and the driving field, the direct Rabi method leads to a rapid decay of oscillations for weak signals, thereby limiting the lower bound of the measurable amplitude. Our experimental observation confirms that the microwave dressed states generated by the CCDD enable the measurement of weaker signals. These findings provide important insights into sensitive measurement of weak GHz-range AC magnetic fields under ensemble inhomogeneities.
The homogeneity of the microwave magnetic field is essential in controlling a large volume of ensemble spins, for example, in the case of sensitive magnetometry with nitrogen-vacancy (NV) centers in diamond. This is particularly important for pulsed measurement, where the fidelity of control pulses plays a crucial role in its sensitivity. So far, several magnetic field-forming systems have been proposed, but no detailed comparison has been made. Here, we numerically study the homogeneity of five different systems, including a planar antenna, a dielectric resonator, a cylindrical inductor, a barrel-shaped coil, and a nested barrel-shaped coil. The results of the simulation allowed us to optimize the design parameters of the barrel-shaped field-forming system, which led to significantly improved magnetic field uniformity. To measure this effect, we experimentally compared the homogeneity of a field-forming system having a barrel shape with that of a planar field-forming system by measuring Rabi oscillations of an ensemble of NV centers with them. Significant improvements in inhomogeneity were confirmed in the barrel-shaped coil.
The sensitivity of a practical quantum magnetometer is challenged by both inhomogeneous coupling between sensors and environment and errors in quantum control. Based on the physical criteria of modern quantum sensing, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening of sensor and control errors via optimized modulation of control field. Such a technique is verified on nitrogen-vacancy (NV) center in diamond to keep almost perfect operation up to a detuning as larger as 110%110\%110%. The sensitivity of the magnetometer with NV center ensemble is experimentally improved by a factor of 444, comparing to dynamical decoupling with normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in realistic systems. The used principle however, is universal and not restricted to NV center ensemble magnetometer.
The sensitivity of practical solid quantum sensing can be boosted up by increasing the number of probes. However, the effects of spin dephasing caused by inhomogeneous broadening and imperfect quantum control can reduce the fidelity of quantum control and the sensitivity of quantum sensing with the dense ensemble of probes, such as nitrogen-vacancy (NV) centers in diamond. Here, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening and control errors via optimized modulation of the control field. Such a composite-pulse was verified on NV center to keep high fidelity quantum control up to a spectrum detuning as large as 110% of Rabi frequency. The sensitivity of the magnetometer with NV center ensemble was experimentally improved by a factor of 4, comparing to dynamical decoupling with a normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in practical applications. The used principle is universal and not restricted to NV center ensemble magnetometer.
Spin ensembles show increasing promise for highly efficient quantum sensing and quantum technologies. However, protecting their coherent properties remains a significant challenge. Dynamical decoupling (DD) typically employs a sequence of fast pulses that aim to reduce the effect of unwanted system-environment interactions. However, the performance of the DD sequences typically suffers in spin ensembles, e.g., due to amplitude and frequency inhomogeneities and control errors. In this work, we compare the performance of an extensive number of DD protocols for coherence protection and quantum sensing in an ensemble of negatively charged NV centers under ambient conditions. We identify the optimal approach that uses rapid adiabatic passage pulses, which are robust to amplitude and frequency inhomogeneity, in combination with the variation of their phases. We experimentally demonstrate an improved signal contrast and an order-of-magnitude increase in memory time with the optimal sequence compared to the widely used XY8 with standard rectangular pulses. We also apply our approach for improved sensing of a weak oscillating field. While our particular demonstration is with NV centers in diamond, the optimized protocol is generally applicable to other spin ensembles and to systems with high amplitude and/or frequency inhomogeneities.