Composite-pulse enhanced room-temperature diamond magnetometry

Yang Dong, Jingyan Xu, Shao-Chun Zhang, Y. H. Zheng, Xiang-Dong Chen, Wei Zhu, Guanzhong Wang, Guang‐Can Guo, Fang‐Wen Sun

Published Jan 2, 2021• 8 citations
Publisher

Abstract

The sensitivity of practical solid quantum sensing can be boosted up by increasing the number of probes. However, the effects of spin dephasing caused by inhomogeneous broadening and imperfect quantum control can reduce the fidelity of quantum control and the sensitivity of quantum sensing with the dense ensemble of probes, such as nitrogen-vacancy (NV) centers in diamond. Here, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening and control errors via optimized modulation of the control field. Such a composite-pulse was verified on NV center to keep high fidelity quantum control up to a spectrum detuning as large as 110% of Rabi frequency. The sensitivity of the magnetometer with NV center ensemble was experimentally improved by a factor of 4, comparing to dynamical decoupling with a normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in practical applications. The used principle is universal and not restricted to NV center ensemble magnetometer.

DOI
10.1080/26941112.2021.1898792

Related papers

Room-temperature Composite-pulses for Robust Diamond Magnetometry

Jingyan Xu, Dong, Yang, Shao-Chun Zhang +6 more

The sensitivity of a practical quantum magnetometer is challenged by both inhomogeneous coupling between sensors and environment and errors in quantum control. Based on the physical criteria of modern quantum sensing, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening of sensor and control errors via optimized modulation of control field. Such a technique is verified on nitrogen-vacancy (NV) center in diamond to keep almost perfect operation up to a detuning as larger as $110\%$. The sensitivity of the magnetometer with NV center ensemble is experimentally improved by a factor of $4$, comparing to dynamical decoupling with normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in realistic systems. The used principle however, is universal and not restricted to NV center ensemble magnetometer.

arXiv:1811.00191•Nov 1, 2018•2 citations

Broadband composite pulse for quantum sensing with a solid-state spin in diamond

Yang Dong, Xuedong Gao, Cui Yu +5 more

High fidelity quantum operation of qubits plays an important role in realistic quantum sensing. It becomes more challenging when there are inevitable interactions between qubits in the solid system. We employ a composite pulse sequence to deal with the problems. The electron spin state of the nitrogen-vacancy center in diamond is flipped with high fidelity by the composite pulse at room temperature. In contrast with traditional rectangular pulses, the composite pulse has a wider excitation profile at the same Rabi frequency. Hence, the three sublevels of host nitrogen nuclear spin can be flipped efficiently and simultaneously, which enhances the signal contrast and detection sensitivity of quantum sensing universally. The enhancement effect works over a wide range of bias magnetic fields. Our scheme can be used for sensing temperature, strain, and electric field and can be applied to other spin–spin coupling systems.

Applied Physics Letters•May 9, 2022•2 citations

Quantifying the performance of multipulse quantum sensing

Yang Dong, Shao-Chun Zhang, Hao-Bin Lin +5 more

The quality of a quantum operation determines the performance of quantum information processing, such as the sensitivity of quantum sensing. Different from the fidelity of quantum operation in quantum computation, we present an effective function to evaluate the performance and diagnose the imperfection of operations in multipulse based quantum sensing. The evaluation function directly links the realistic sensitivity with intrinsic sensitivity in a simple way. Moreover, guided by this evaluation function, we optimize a composite-pulse sequence for high sensitivity nitrogen-vacancy- center based magnetometry against spectrum inhomogeneities and control errors to improve the signal-to-noise ratio of nanoscale nuclear magnetic resonance by one order of magnitude. It marks an important step towards quantitative quantum sensing with imperfect quantum control in practical applications.

arXiv:2003.02472•Physical review. B./Physical review. B•Mar 15, 2021•7 citations

Robust control of an ensemble of NV centers in diamond under inhomogeneous fields for sensitive magnetometry

Takuya Kitamura

Quantum sensing with solid-state spins has attracted considerable attention following the development of single quantum systems. In particular, sub-picotesla level magnetometry has been demonstrated using negatively-charged nitrogen-vacancy (NV) centers in diamond by increasing the number of spins simultaneously employed for sensing. However, scaling up the number of spins inevitably introduces inhomogeneities in detuning and control field amplitudes across the ensemble system, which degrades the achievable sensitivity. Although several techniques, including pulsed dynamical decoupling and shaped pulses, have been studied to overcome such noises, they are not generally compatible with GHz-range AC magnetometry based on Rabi oscillations. This dissertation presents the development of an experimental platform and the demonstration of robust GHz-range AC magnetometry using a large ensemble of NV centers under inhomogeneous fields. Particular emphasis is placed on the effects of control-field amplitude inhomogeneity. To improve the homogeneity of the control field, barrel-shaped microwave forming systems are experimentally characterized, and their performance is compared with that of planar systems. Then, to mitigate detuning noise as well as control-field amplitude noise, concatenated continuous dynamical decoupling (CCDD) is applied to the inhomogeneous ensemble system, and the resulting dynamics are investigated with several initial states prepared with composite pulses. Finally, the CCDD sequence is applied for GHz-range AC magnetometry and compared with the conventional direct Rabi method. The results demonstrate that the robust dressed states generated by CCDD extend the lower bound of measurable amplitudes in GHz-range AC magnetometry.

•Jan 1, 2026•0 citations

Optimized Dynamical Decoupling for Spin Ensembles with Large Inhomogeneities

Rajan Paul, Genko Genov, Oliver Schmid +4 more

Spin ensembles show increasing promise for highly efficient quantum sensing and quantum technologies. However, protecting their coherent properties remains a significant challenge. Dynamical decoupling (DD) typically employs a sequence of fast pulses that aim to reduce the effect of unwanted system-environment interactions. However, the performance of the DD sequences typically suffers in spin ensembles, e.g., due to amplitude and frequency inhomogeneities and control errors. In this work, we compare the performance of an extensive number of DD protocols for coherence protection and quantum sensing in an ensemble of negatively charged NV centers under ambient conditions. We identify the optimal approach that uses rapid adiabatic passage pulses, which are robust to amplitude and frequency inhomogeneity, in combination with the variation of their phases. We experimentally demonstrate an improved signal contrast and an order-of-magnitude increase in memory time with the optimal sequence compared to the widely used XY8 with standard rectangular pulses. We also apply our approach for improved sensing of a weak oscillating field. While our particular demonstration is with NV centers in diamond, the optimized protocol is generally applicable to other spin ensembles and to systems with high amplitude and/or frequency inhomogeneities.

quant-pharXiv:2610.39693•Oct 30, 2026•0 citations

High-sensitivity double-quantum magnetometry in diamond via quantum control

Yang Dong, Hao-Bin Lin, Wei Zhu +1 more

High-fidelity quantum operation of qubits plays an important role in magnetometry based on nitrogen-vacancy (NV) centers in diamonds. However, the nontrivial spin-spin coupling of the NV center decreases signal contrast and sensitivity. Here, we overcome this limitation by exploiting the amplitude modulation of microwaves, which allows us to perfectly detect magnetic signals at low fields. Compared with the traditional double-quantum sensing protocol, the full contrast of the detection signal was recovered, and the sensitivity was enhanced three times in the experiment. Our method is applicable to a wide range of sensing tasks, such as temperature, strain, and electric field.

JUSTC•Jan 1, 2022•1 citation
The sensitivity of practical solid quantum sensing can be boosted up by increasing the number of probes. However, the effects of spin dephasing caused by inhomogeneous broadening and imperfect quantum control can reduce the fidelity of quantum control and the sensitivity of quantum sensing with the dense ensemble of probes, such as nitrogen-vacancy (NV) centers in diamond. Here, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening and control errors via optimized modulation of the control field. Such a composite-pulse was verified on NV center to keep high fidelity quantum control up to a spectrum detuning as large as 110% of Rabi frequency. The sensitivity of the magnetometer with NV center ensemble was experimentally improved by a factor of 4, comparing to dynamical decoupling with a normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in practical applications. The used principle is universal and not restricted to NV center ensemble magnetometer.
The sensitivity of a practical quantum magnetometer is challenged by both inhomogeneous coupling between sensors and environment and errors in quantum control. Based on the physical criteria of modern quantum sensing, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening of sensor and control errors via optimized modulation of control field. Such a technique is verified on nitrogen-vacancy (NV) center in diamond to keep almost perfect operation up to a detuning as larger as 110%110\%110%. The sensitivity of the magnetometer with NV center ensemble is experimentally improved by a factor of 444, comparing to dynamical decoupling with normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in realistic systems. The used principle however, is universal and not restricted to NV center ensemble magnetometer.
High fidelity quantum operation of qubits plays an important role in realistic quantum sensing. It becomes more challenging when there are inevitable interactions between qubits in the solid system. We employ a composite pulse sequence to deal with the problems. The electron spin state of the nitrogen-vacancy center in diamond is flipped with high fidelity by the composite pulse at room temperature. In contrast with traditional rectangular pulses, the composite pulse has a wider excitation profile at the same Rabi frequency. Hence, the three sublevels of host nitrogen nuclear spin can be flipped efficiently and simultaneously, which enhances the signal contrast and detection sensitivity of quantum sensing universally. The enhancement effect works over a wide range of bias magnetic fields. Our scheme can be used for sensing temperature, strain, and electric field and can be applied to other spin–spin coupling systems.
The quality of a quantum operation determines the performance of quantum information processing, such as the sensitivity of quantum sensing. Different from the fidelity of quantum operation in quantum computation, we present an effective function to evaluate the performance and diagnose the imperfection of operations in multipulse based quantum sensing. The evaluation function directly links the realistic sensitivity with intrinsic sensitivity in a simple way. Moreover, guided by this evaluation function, we optimize a composite-pulse sequence for high sensitivity nitrogen-vacancy- center based magnetometry against spectrum inhomogeneities and control errors to improve the signal-to-noise ratio of nanoscale nuclear magnetic resonance by one order of magnitude. It marks an important step towards quantitative quantum sensing with imperfect quantum control in practical applications.
Quantum sensing with solid-state spins has attracted considerable attention following the development of single quantum systems. In particular, sub-picotesla level magnetometry has been demonstrated using negatively-charged nitrogen-vacancy (NV) centers in diamond by increasing the number of spins simultaneously employed for sensing. However, scaling up the number of spins inevitably introduces inhomogeneities in detuning and control field amplitudes across the ensemble system, which degrades the achievable sensitivity. Although several techniques, including pulsed dynamical decoupling and shaped pulses, have been studied to overcome such noises, they are not generally compatible with GHz-range AC magnetometry based on Rabi oscillations. This dissertation presents the development of an experimental platform and the demonstration of robust GHz-range AC magnetometry using a large ensemble of NV centers under inhomogeneous fields. Particular emphasis is placed on the effects of control-field amplitude inhomogeneity. To improve the homogeneity of the control field, barrel-shaped microwave forming systems are experimentally characterized, and their performance is compared with that of planar systems. Then, to mitigate detuning noise as well as control-field amplitude noise, concatenated continuous dynamical decoupling (CCDD) is applied to the inhomogeneous ensemble system, and the resulting dynamics are investigated with several initial states prepared with composite pulses. Finally, the CCDD sequence is applied for GHz-range AC magnetometry and compared with the conventional direct Rabi method. The results demonstrate that the robust dressed states generated by CCDD extend the lower bound of measurable amplitudes in GHz-range AC magnetometry.
Spin ensembles show increasing promise for highly efficient quantum sensing and quantum technologies. However, protecting their coherent properties remains a significant challenge. Dynamical decoupling (DD) typically employs a sequence of fast pulses that aim to reduce the effect of unwanted system-environment interactions. However, the performance of the DD sequences typically suffers in spin ensembles, e.g., due to amplitude and frequency inhomogeneities and control errors. In this work, we compare the performance of an extensive number of DD protocols for coherence protection and quantum sensing in an ensemble of negatively charged NV centers under ambient conditions. We identify the optimal approach that uses rapid adiabatic passage pulses, which are robust to amplitude and frequency inhomogeneity, in combination with the variation of their phases. We experimentally demonstrate an improved signal contrast and an order-of-magnitude increase in memory time with the optimal sequence compared to the widely used XY8 with standard rectangular pulses. We also apply our approach for improved sensing of a weak oscillating field. While our particular demonstration is with NV centers in diamond, the optimized protocol is generally applicable to other spin ensembles and to systems with high amplitude and/or frequency inhomogeneities.
High-fidelity quantum operation of qubits plays an important role in magnetometry based on nitrogen-vacancy (NV) centers in diamonds. However, the nontrivial spin-spin coupling of the NV center decreases signal contrast and sensitivity. Here, we overcome this limitation by exploiting the amplitude modulation of microwaves, which allows us to perfectly detect magnetic signals at low fields. Compared with the traditional double-quantum sensing protocol, the full contrast of the detection signal was recovered, and the sensitivity was enhanced three times in the experiment. Our method is applicable to a wide range of sensing tasks, such as temperature, strain, and electric field.