Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Science and Technology

Single-beam atomic magnetometry with sub-nanotesla heading error based on hyperfine alignment resonances

Junlin Chen, Liwei Jiang, Jiaqi Yang, Changhao Zhang, Zhihao Peng, Shihao Bei, Jiali Liu

Published Sep 21, 2026• 0 citations
Publisher

Abstract

Heading error is a major limitation for resonance-based atomic magnetometers operating in the geomagnetic-field range, where the magnetic-field direction often changes with respect to the sensor. Here, we investigate the physical origin of heading error in a single-beam amplitude-modulated nonlinear magneto-optical rotation magnetometer based on the hyperfine alignment resonances of the 87 Rb D1 line in a buffer-gas vapor cell. Unlike orientation-based magnetometers, where nonlinear Zeeman effects usually constitute a major source of heading error, the F = 2 alignment resonance spectrum maintains a stable center frequency under different magnetic-field orientations when the individual resonance components are unresolved. In practical single-beam measurements, the observed heading error is associated with an orientation-dependent residual spectral background, which breaks the apparent symmetry of the alignment-resonance profile and biases the extracted center frequency. To suppress this background-induced bias, we propose a multi-point frequency extraction method that retrieves the resonance center from distorted single-beam spectra. In unshielded geomagnetic-field measurements, the equal-weight pooled peak-to-peak heading-error estimate for the F = 2 manifold is reduced to 0.32 nT, with a one-sided 95% upper coverage limit of 0.90 nT. Separately, an estimated photon-shot-noise-limited sensitivity of about 23 fT / Hz 1 / 2 is obtained. These results provide a compact route to low-heading-error and high-sensitivity atomic magnetometry for practical geomagnetic-field quantum sensing.

DOI
10.1088/2058-9565/aea442

Related papers

Heading error in an alignment-based magnetometer

Chris Hovde, Brian Patton, Oscar O. Versolato +3 more

A prototype magnetometer for anti-submarine warfare applications is being developed based on nonlinear magneto-optical rotation (NMOR) in atomic vapors. NMOR is an atomic spectroscopy technique that exploits coherences among magnetic sublevels of atoms such as cesium or rubidium to measure magnetic fields with high precision. NMOR uses stroboscopic optical pumping via frequency or amplitude modulation of a linearly polarized laser beam to create the alignment. An anti-relaxation coating on the walls of the atomic vapor cell can result in a long lifetime of 1 s or more for the coherence and enables precise measurement of the precession frequency. With proper feedback, the magnetometer can self-oscillate, resulting in accurate tracking and fast time response. The NMOR magnetic resonance spectrum of 87Rb has been measured as a function of heading in Earth's field. Optical pumping of alignment within the F=2 hyperfine manifold generates three resonances separated by the nonlinear Zeeman splitting. The spectra show a high degree of symmetry, consisting of a central peak and two side peaks of nearly equal intensity. As the heading changes, the ratio of the central peak to the average of the two side peaks changes. The amplitudes of the side peaks remain nearly equal. An analysis of the forced oscillation spectra indicates that, away from dead zones, heading error in self-oscillating mode should be less than 1 nT. A broader background is also observed in the spectra. While this background can be removed when fitting resonance spectra, understanding it will be important to achieving the small heading error in self-oscillating mode that is implied by the spectral measurements. Progress in miniaturizing the magnetometer is also reported. The new design is less than 10 cm across and includes fiber coupling of light to and from the magnetometer head. Initial tests show that the prototype has achieved a narrow spectral width and a strong polarization rotation signal.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 13, 2011•7 citations

Heading-Error-Free Optical Atomic Magnetometry in the Earth-Field Range

Rui Zhang, Dimitra Kanta, Arne Wickenbrock +2 more

We demonstrate an alignment-based $^{87}\mathrm{Rb}$ magnetometer that is immune to nonlinear Zeeman (NLZ) splitting, addressing an important problem in alkali-metal atomic magnetometry. In our scheme, there is a single magnetic resonance peak and well-separated hyperfine transition frequencies, making the magnetometer insensitive or even immune to NLZ-related heading errors. It is shown that the magnetometer can be implemented for practical measurements in geomagnetic environments, and the photon-shot-noise-limited sensitivity reaches $9\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ at $5\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{T}$ and remains at tens of $\mathrm{fT}/\sqrt{\mathrm{Hz}}$ at $50\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{T}$ at room temperature.

arXiv:2204.05071•Physical Review Letters•Apr 12, 2023•38 citations

Suppression of the Nonlinear Zeeman Effect and Heading Error in Earth-Field-Range Alkali-Vapor Magnetometers

Guzhi Bao, Arne Wickenbrock, Simon Rochester +2 more

The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ∼100 Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.

arXiv:1708.05262•Physical Review Letters•Jan 17, 2018•77 citations

Suppression of heading errors in Bell-Bloom optically pumped free-induction-decay alkali-metal atomic magnetometers

S.-Q. Liu, X.-K. Wang, Xiangdong Zhang +2 more

Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.

arXiv:2502.13414•Physical Review A•Feb 26, 2025•7 citations

Correcting heading errors in optically pumped magnetometers through microwave interrogation

Christopher Kiehl, Thanmay S. Menon, D. P. Hewatt +3 more

We demonstrate how to measure in situ for heading errors of optically pumped magnetometers (OPMs) in the challenging parameter regime of compact vapor cells with imperfect optical pumping and high buffer gas pressure. For this, we utilize microwave-driven Ramsey and Rabi frequency spectroscopy (FS) to independently characterize scalar heading errors in free-induction-decay (FID) signals. Both of these approaches suppress 5-nT inaccuracies in geomagnetic fields caused by nonlinear Zeeman shifts in FID measurements to below 0.6 nT. For Ramsey FS, we implement short periods of microwave interrogation within a $\ensuremath{\pi}/2\text{\ensuremath{-}}{t}_{R}\text{\ensuremath{-}}3\ensuremath{\pi}/2$ Ramsey interferometry sequence, effectively circumventing systematic errors from off-resonant driving. Conversely, Rabi FS leverages an atom-microwave Hamiltonian for accurate modeling of Rabi oscillation frequencies, achieving a measurement precision down to $80\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/\sqrt{\text{Hz}}$ that is limited primarily by technical microwave noise. We show that the fundamental sensitivity of Rabi FS is $30\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/\sqrt{\text{Hz}}$ with our vapor cell parameters through a Cram\'er-Rao lower-bound analysis. This work paves the way for future investigations into the accuracy of hyperfine structure magnetometry and contributes to the broader applicability of OPMs in fields ranging from navigation and geophysics to space exploration and unexploded ordinance detection, where heading error mitigation is essential.

arXiv:2310.11017•Physical Review Applied•Jul 2, 2024•13 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•6 citations
Heading error is a major limitation for resonance-based atomic magnetometers operating in the geomagnetic-field range, where the magnetic-field direction often changes with respect to the sensor. Here, we investigate the physical origin of heading error in a single-beam amplitude-modulated nonlinear magneto-optical rotation magnetometer based on the hyperfine alignment resonances of the 87 Rb D1 line in a buffer-gas vapor cell. Unlike orientation-based magnetometers, where nonlinear Zeeman effects usually constitute a major source of heading error, the F = 2 alignment resonance spectrum maintains a stable center frequency under different magnetic-field orientations when the individual resonance components are unresolved. In practical single-beam measurements, the observed heading error is associated with an orientation-dependent residual spectral background, which breaks the apparent symmetry of the alignment-resonance profile and biases the extracted center frequency. To suppress this background-induced bias, we propose a multi-point frequency extraction method that retrieves the resonance center from distorted single-beam spectra. In unshielded geomagnetic-field measurements, the equal-weight pooled peak-to-peak heading-error estimate for the F = 2 manifold is reduced to 0.32 nT, with a one-sided 95% upper coverage limit of 0.90 nT. Separately, an estimated photon-shot-noise-limited sensitivity of about 23 fT / Hz 1 / 2 is obtained. These results provide a compact route to low-heading-error and high-sensitivity atomic magnetometry for practical geomagnetic-field quantum sensing.
A prototype magnetometer for anti-submarine warfare applications is being developed based on nonlinear magneto-optical rotation (NMOR) in atomic vapors. NMOR is an atomic spectroscopy technique that exploits coherences among magnetic sublevels of atoms such as cesium or rubidium to measure magnetic fields with high precision. NMOR uses stroboscopic optical pumping via frequency or amplitude modulation of a linearly polarized laser beam to create the alignment. An anti-relaxation coating on the walls of the atomic vapor cell can result in a long lifetime of 1 s or more for the coherence and enables precise measurement of the precession frequency. With proper feedback, the magnetometer can self-oscillate, resulting in accurate tracking and fast time response. The NMOR magnetic resonance spectrum of 87Rb has been measured as a function of heading in Earth's field. Optical pumping of alignment within the F=2 hyperfine manifold generates three resonances separated by the nonlinear Zeeman splitting. The spectra show a high degree of symmetry, consisting of a central peak and two side peaks of nearly equal intensity. As the heading changes, the ratio of the central peak to the average of the two side peaks changes. The amplitudes of the side peaks remain nearly equal. An analysis of the forced oscillation spectra indicates that, away from dead zones, heading error in self-oscillating mode should be less than 1 nT. A broader background is also observed in the spectra. While this background can be removed when fitting resonance spectra, understanding it will be important to achieving the small heading error in self-oscillating mode that is implied by the spectral measurements. Progress in miniaturizing the magnetometer is also reported. The new design is less than 10 cm across and includes fiber coupling of light to and from the magnetometer head. Initial tests show that the prototype has achieved a narrow spectral width and a strong polarization rotation signal.
We demonstrate an alignment-based 87Rb^{87}\mathrm{Rb}87Rb magnetometer that is immune to nonlinear Zeeman (NLZ) splitting, addressing an important problem in alkali-metal atomic magnetometry. In our scheme, there is a single magnetic resonance peak and well-separated hyperfine transition frequencies, making the magnetometer insensitive or even immune to NLZ-related heading errors. It is shown that the magnetometer can be implemented for practical measurements in geomagnetic environments, and the photon-shot-noise-limited sensitivity reaches 9  fT/Hz9\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}9  fT/Hz​ at $5\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{T}$ and remains at tens of fT/Hz\mathrm{fT}/\sqrt{\mathrm{Hz}}fT/Hz​ at $50\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{T}$ at room temperature.
The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ∼100 Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.
Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.
We demonstrate how to measure in situ for heading errors of optically pumped magnetometers (OPMs) in the challenging parameter regime of compact vapor cells with imperfect optical pumping and high buffer gas pressure. For this, we utilize microwave-driven Ramsey and Rabi frequency spectroscopy (FS) to independently characterize scalar heading errors in free-induction-decay (FID) signals. Both of these approaches suppress 5-nT inaccuracies in geomagnetic fields caused by nonlinear Zeeman shifts in FID measurements to below 0.6 nT. For Ramsey FS, we implement short periods of microwave interrogation within a $\ensuremath{\pi}/2\text{\ensuremath{-}}{t}_{R}\text{\ensuremath{-}}3\ensuremath{\pi}/2$ Ramsey interferometry sequence, effectively circumventing systematic errors from off-resonant driving. Conversely, Rabi FS leverages an atom-microwave Hamiltonian for accurate modeling of Rabi oscillation frequencies, achieving a measurement precision down to 80pT/Hz80\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/\sqrt{\text{Hz}}80pT/Hz​ that is limited primarily by technical microwave noise. We show that the fundamental sensitivity of Rabi FS is 30pT/Hz30\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/\sqrt{\text{Hz}}30pT/Hz​ with our vapor cell parameters through a Cram\'er-Rao lower-bound analysis. This work paves the way for future investigations into the accuracy of hyperfine structure magnetometry and contributes to the broader applicability of OPMs in fields ranging from navigation and geophysics to space exploration and unexploded ordinance detection, where heading error mitigation is essential.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.