Enhancement of Atomic Spin Gyroscopes Under Thermo-Mechanical Coupling: A Physics-Informed Measurement and Estimation Approach

Zehua Liu, Deng Silu, Zhuo Wang, Haoying Pang, Yifan Yan, Xusheng Lei, Junping Wang, Wei Quan

Published Jan 1, 2026• 0 citations
Publisher

Abstract

In high-precision inertial measurement, the structural bias drift of atomic spin gyroscopes (ASGs) induced by residual thermo-mechanical coupling remains a critical limiting factor for long-term stability. This article presents a physics-informed adaptive measurement and compensation framework designed to suppress these deterministic and stochastic errors. Unlike pure data-driven models, the proposed method characterizes the physical coupling mechanisms to enhance the traceability of the estimation process. Two key metrological innovations are introduced: a statistical-physical dual-threshold gating mechanism that ensures causality in error detection to shield against nonphysical sensor noise, and an excitation-guided anisotropic injection strategy for decoupling channel-wise measurement uncertainties. This approach enables stable locking of quiescent parameters while maintaining rapid response to transient thermal disturbances. Experimental evaluation indicates that the proposed method reduces the bias instability (BI) by 8.66 dB and suppresses the rate random walk (RRW) coefficient by 32.41 dB. By providing a rigorous uncertainty analysis and decoupling recessive signal dynamics from environmental interferences, this work establishes a robust instrumentation paradigm for deploying quantum sensors in complex environments.

DOI
10.1109/tim.2026.3720805

Related papers

A Noise Diagnostic and Suppression Methodology for Improving Measurement Stability of SERF Atomic Sensors

Jiaxin Liu, Puchen Gong, Xusheng Lei +1 more

Achieving high measurement stability in spin exchange relaxation free (SERF) atomic sensors is a central challenge in quantum instrumentation, yet the intrinsic noise mechanisms that ultimately limit measurement performance remain insufficiently characterized. This article proposes a model-based noise diagnostic and suppression methodology that systematically links microscopic spin fluctuations to macroscopic measurement noise. The Langevin stochastic terms are introduced into the coupled Bloch equations to form a noise characterization framework that captures stochastic excitation, dissipation, and finite correlation of the coupled electronic and nuclear spin modes, enabling identification and quantification of the noise sources responsible for spectral coloring and low-frequency accumulation in the measurement output. Two previously overlooked noise amplification pathways in the measurement system are diagnosed: projection leakage caused by nonorthogonal optical readout geometry and stochastic magnetic injection introduced by electromagnetic coupling in the temperature control subsystem. For each pathway, the targeted instrumentation optimization procedures are derived and implemented. The experimental evaluation on a SERF atomic gyroscope demonstrates that joint optimization of the heating and optical subsystems reduces the amplitude spectral density at 1 Hz from$7.66 \times 10^{-6}$to$3.12 \times 10^{{-6} {\circ }} $/s$/\sqrt {\mathrm {Hz}}$, a 41.6% improvement, and suppresses the nonwhite hump in the Allan deviation over$\tau \approx 0.1$–10 s. The proposed methodology provides a reusable, physics-informed route for diagnosing, attributing, and mitigating noise in high-stability quantum measurement systems.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

Closed-loop atomic spin gyroscope via injection current modulation and magnetic feedback

Xiaoping Li, Wenfeng Fan, Shimiao Fan +1 more

In traditional spin-exchange relaxation-free (SERF) gyroscopes, open-loop detection leaves the scale factor vulnerable to fluctuations in probe laser intensity and environmental temperature. To address this, an external-modulator-free closed-loop atomic spin gyroscope (ASG) is demonstrated using direct probe laser injection current modulation. A magnetic feedback loop maintains the total optical rotation at a zero point, decoupling the inertial signal from intensity and optical depth variations. Experimental results demonstrate a closed-loop rotation sensitivity of 2.8×10 −6 °/s/Hz 1/2 at 1 Hz. Compared to open-loop measurements under identical conditions (1×10 −5 ∘ /s/Hz 1/2 ), low-frequency noise is significantly suppressed. By eliminating bulky external modulators and effectively suppressing low-frequency noise, this design offers a highly competitive architecture for miniaturized atomic inertial sensors.

Optics Letters•Apr 30, 2026•0 citations

Analysis and suppression of spin polarization error in atomic spin gyroscope based on adaptive light compensation

Zehua Liu, Yifan Yan, Zhuo Wang +5 more

• A dual-spectrum feedback architecture based on conventional closed-loop control is proposed, enabling real-time compensation for spin polarization error (SPE) in the K-Rb-21Ne atomic spin gyroscope, significantly enhancing long-term stability. • An adaptive dynamic control strategy based on a Lyapunov function is introduced to replace PID control, optimizing control parameters and improving system response speed and stability. • Experimental results show that the method improves SPE suppression by 54.4%, 74.5%, and 74.6% for clustering times of 100s, 500s, and 1000s, respectively. • Interference tests demonstrate that the method effectively eliminates steady-state offsets and enhances the system's adaptability to power density and polarization fluctuations, providing a long-term stability solution for optically pumped atomic devices. The long-term stability of atomic spin polarization plays a critical role in ensuring the sustained stability of atomic gyroscope outputs. However, drift in the laser pumping rate introduces the spin polarization error (SPE), necessitating high-precision closed-loop stabilization. Conventional single-beam-splitting closed-loop control methods overlook the time-varying characteristics of beam-splitting elements during prolonged operation, resulting in incomplete suppression of SPE in long-term measurements. To address this limitation, a dynamic light compensation framework is developed for the analysis and suppression of SPE in an atomic spin gyroscope. The proposed structure enables real-time monitoring of parameter variations in the beam-splitting elements and feeds this information back into the control loop to actively compensate for polarization errors induced by optical drift. Furthermore, an adaptive control method based on nonlinear inversion and disturbance observation is introduced, which estimates the internal state and compensates time-varying parameters in real time, thereby replacing conventional PID control and ensuring optimal closed-loop performance. Experimental results from a K-Rb- 21 Ne atomic gyroscope demonstrate real-time suppression of SPE, with improvements of 54.4%, 74.5%, and 74.6% for clustering times of 100, 500, and 1000 seconds, respectively. Interference tests show enhanced response speed and the elimination of steady-state offsets under power density and polarization disturbances. This method offers a novel solution for achieving long-term stability in optically pumped atomic devices, ensuring sustained measurement accuracy.

Results in Engineering•Dec 25, 2025•0 citations

The noise analysis and multi-physical field coupling study of high-precision SERF atomic gyroscopes

Jiaxin Liu, Xusheng Lei, Yu Yuan +3 more

The spin-exchange relaxation-free atomic gyroscope, with its exceptionally high theoretical precision, demonstrates immense potential to become the next-generation strategic-grade gyroscope. However, due to technological noise, there is still a significant gap between its actual precision and theoretical precision. This study identifies the key factor limiting the precision of the SERF gyroscope as coupling noise. By optimizing the detection loop structure, a distinction between the dual-axis signals' response to optical and magnetic fields was achieved—where the optical errors responded similarly, while the response to magnetic noise was opposite. Based on the differences in the optical-magnetic response of the dual-axis signals, empirical mode decomposition was used to decompose the dual-axis gyroscope signals into multiple intrinsic mode functions, and Allan deviation analysis was applied to analyze the noise characteristics of the intrinsic mode functions over various periods. This study successfully reveals that optical errors caused by thermal-optical coupling and long-period magnetic noise induced by thermal-magnetic coupling are the dominant factors limiting the long-term stability of the SERF gyroscope. Based on these analyses, the study concludes that to achieve strategic-grade precision for the SERF gyroscope, it is essential to effectively address the noise issues caused by multi-physical field couplings.

Defence Technology•Apr 26, 2025•18 citations

Atomic density disturbance rejection in atomic gyroscopes via faraday polarimetric decoupling

Zehua Liu, Yifan Yan, Haoying Pang +5 more

Atomic spin gyroscopes are promising candidates for next-generation inertial navigation due to extremely high theoretical precision, relatively small size among atomic gyroscopes, and promising potential for miniaturization. In particular, the spin-exchange relaxation-free (SERF) atomic gyroscope relies on optical pumping to polarize atoms, enabling rotation sensing through the Faraday optical rotation angle (FORA). However, fluctuations in atomic density introduce systematic errors in FORA measurements, limiting long-term stability. We present a data-driven decoupling method that isolates atomic density fluctuations from the FORA signal by modeling spatially resolved light absorption in the vapor cell. The model accounts for the spatial distribution of spin polarization in the pump-light interaction volume, density-dependent relaxation rates, wall-induced relaxation, and polarization diffusion, and is implemented within a finite-element framework. Compared to the conventional Lambert-Beer law, which assumes one-dimensional homogeneity, our approach captures the full three-dimensional density and polarization distribution, significantly improving the accuracy of light absorption modeling. The resulting absorption-density maps are used to train a feedforward neural network, yielding a high-precision estimator for atomic density fluctuations. This estimator enables the construction of a decoupling equation that separates the density contribution from the FORA signal. Experimental validation shows that this method improves the bias instability at σ (100 s) of the gyroscope was improved by 73.1% compared to traditional platinum-resistance-based stabilization. The proposed framework is general and can be extended to other optical pumping-based sensors, such as optically pumped magnetometers.

Defence Technology•Jul 25, 2025•2 citations

Decoupling and suppression of opto-thermal drifts in SERF atomic co-magnetometers via precise null-point characterization

Xiaoping Li, Wenfeng Fan, Shimiao Fan +2 more

The long-term bias stability of spin-exchange relaxation-free atomic co-magnetometers is significantly constrained by coupled opto-thermal fluctuations. Traditionally, random systemic offsets at the magnetic compensation point lead to inconsistent opto-thermal coupling, compromising the reproducibility of sensor performance. In this work, we propose a method to simultaneously decouple and suppress these primary drifts by precisely characterizing the physical null-point of the atomic ensemble. A combined compensation scheme, joining residual rotation angle alignment and transverse magnetic field adjustment, is implemented to isolate the sensor output from fluctuations in probe laser intensity and vapor cell temperature. Experimental results demonstrate that the sensitivities to temperature drifts and probe power fluctuations are suppressed simultaneously at the identified null-point by factors of 72 and 880, respectively. This approach establishes a stable zero point, which is expected to significantly enhance sensor reproducibility and stability without sacrificing fundamental sensing performance.

Applied Physics Letters•Apr 20, 2026•4 citations
In high-precision inertial measurement, the structural bias drift of atomic spin gyroscopes (ASGs) induced by residual thermo-mechanical coupling remains a critical limiting factor for long-term stability. This article presents a physics-informed adaptive measurement and compensation framework designed to suppress these deterministic and stochastic errors. Unlike pure data-driven models, the proposed method characterizes the physical coupling mechanisms to enhance the traceability of the estimation process. Two key metrological innovations are introduced: a statistical-physical dual-threshold gating mechanism that ensures causality in error detection to shield against nonphysical sensor noise, and an excitation-guided anisotropic injection strategy for decoupling channel-wise measurement uncertainties. This approach enables stable locking of quiescent parameters while maintaining rapid response to transient thermal disturbances. Experimental evaluation indicates that the proposed method reduces the bias instability (BI) by 8.66 dB and suppresses the rate random walk (RRW) coefficient by 32.41 dB. By providing a rigorous uncertainty analysis and decoupling recessive signal dynamics from environmental interferences, this work establishes a robust instrumentation paradigm for deploying quantum sensors in complex environments.
Achieving high measurement stability in spin exchange relaxation free (SERF) atomic sensors is a central challenge in quantum instrumentation, yet the intrinsic noise mechanisms that ultimately limit measurement performance remain insufficiently characterized. This article proposes a model-based noise diagnostic and suppression methodology that systematically links microscopic spin fluctuations to macroscopic measurement noise. The Langevin stochastic terms are introduced into the coupled Bloch equations to form a noise characterization framework that captures stochastic excitation, dissipation, and finite correlation of the coupled electronic and nuclear spin modes, enabling identification and quantification of the noise sources responsible for spectral coloring and low-frequency accumulation in the measurement output. Two previously overlooked noise amplification pathways in the measurement system are diagnosed: projection leakage caused by nonorthogonal optical readout geometry and stochastic magnetic injection introduced by electromagnetic coupling in the temperature control subsystem. For each pathway, the targeted instrumentation optimization procedures are derived and implemented. The experimental evaluation on a SERF atomic gyroscope demonstrates that joint optimization of the heating and optical subsystems reduces the amplitude spectral density at 1 Hz from7.66×10−67.66 \times 10^{-6}7.66×10−6to$3.12 \times 10^{{-6} {\circ }} /s/s/s/\sqrt {\mathrm {Hz}},a41.6, a 41.6% improvement, and suppresses the nonwhite hump in the Allan deviation over,a41.6\tau \approx 0.1$–10 s. The proposed methodology provides a reusable, physics-informed route for diagnosing, attributing, and mitigating noise in high-stability quantum measurement systems.
In traditional spin-exchange relaxation-free (SERF) gyroscopes, open-loop detection leaves the scale factor vulnerable to fluctuations in probe laser intensity and environmental temperature. To address this, an external-modulator-free closed-loop atomic spin gyroscope (ASG) is demonstrated using direct probe laser injection current modulation. A magnetic feedback loop maintains the total optical rotation at a zero point, decoupling the inertial signal from intensity and optical depth variations. Experimental results demonstrate a closed-loop rotation sensitivity of 2.8×10 −6 °/s/Hz 1/2 at 1 Hz. Compared to open-loop measurements under identical conditions (1×10 −5 ∘ /s/Hz 1/2 ), low-frequency noise is significantly suppressed. By eliminating bulky external modulators and effectively suppressing low-frequency noise, this design offers a highly competitive architecture for miniaturized atomic inertial sensors.
• A dual-spectrum feedback architecture based on conventional closed-loop control is proposed, enabling real-time compensation for spin polarization error (SPE) in the K-Rb-21Ne atomic spin gyroscope, significantly enhancing long-term stability. • An adaptive dynamic control strategy based on a Lyapunov function is introduced to replace PID control, optimizing control parameters and improving system response speed and stability. • Experimental results show that the method improves SPE suppression by 54.4%, 74.5%, and 74.6% for clustering times of 100s, 500s, and 1000s, respectively. • Interference tests demonstrate that the method effectively eliminates steady-state offsets and enhances the system's adaptability to power density and polarization fluctuations, providing a long-term stability solution for optically pumped atomic devices. The long-term stability of atomic spin polarization plays a critical role in ensuring the sustained stability of atomic gyroscope outputs. However, drift in the laser pumping rate introduces the spin polarization error (SPE), necessitating high-precision closed-loop stabilization. Conventional single-beam-splitting closed-loop control methods overlook the time-varying characteristics of beam-splitting elements during prolonged operation, resulting in incomplete suppression of SPE in long-term measurements. To address this limitation, a dynamic light compensation framework is developed for the analysis and suppression of SPE in an atomic spin gyroscope. The proposed structure enables real-time monitoring of parameter variations in the beam-splitting elements and feeds this information back into the control loop to actively compensate for polarization errors induced by optical drift. Furthermore, an adaptive control method based on nonlinear inversion and disturbance observation is introduced, which estimates the internal state and compensates time-varying parameters in real time, thereby replacing conventional PID control and ensuring optimal closed-loop performance. Experimental results from a K-Rb- 21 Ne atomic gyroscope demonstrate real-time suppression of SPE, with improvements of 54.4%, 74.5%, and 74.6% for clustering times of 100, 500, and 1000 seconds, respectively. Interference tests show enhanced response speed and the elimination of steady-state offsets under power density and polarization disturbances. This method offers a novel solution for achieving long-term stability in optically pumped atomic devices, ensuring sustained measurement accuracy.
The spin-exchange relaxation-free atomic gyroscope, with its exceptionally high theoretical precision, demonstrates immense potential to become the next-generation strategic-grade gyroscope. However, due to technological noise, there is still a significant gap between its actual precision and theoretical precision. This study identifies the key factor limiting the precision of the SERF gyroscope as coupling noise. By optimizing the detection loop structure, a distinction between the dual-axis signals' response to optical and magnetic fields was achieved—where the optical errors responded similarly, while the response to magnetic noise was opposite. Based on the differences in the optical-magnetic response of the dual-axis signals, empirical mode decomposition was used to decompose the dual-axis gyroscope signals into multiple intrinsic mode functions, and Allan deviation analysis was applied to analyze the noise characteristics of the intrinsic mode functions over various periods. This study successfully reveals that optical errors caused by thermal-optical coupling and long-period magnetic noise induced by thermal-magnetic coupling are the dominant factors limiting the long-term stability of the SERF gyroscope. Based on these analyses, the study concludes that to achieve strategic-grade precision for the SERF gyroscope, it is essential to effectively address the noise issues caused by multi-physical field couplings.
Atomic spin gyroscopes are promising candidates for next-generation inertial navigation due to extremely high theoretical precision, relatively small size among atomic gyroscopes, and promising potential for miniaturization. In particular, the spin-exchange relaxation-free (SERF) atomic gyroscope relies on optical pumping to polarize atoms, enabling rotation sensing through the Faraday optical rotation angle (FORA). However, fluctuations in atomic density introduce systematic errors in FORA measurements, limiting long-term stability. We present a data-driven decoupling method that isolates atomic density fluctuations from the FORA signal by modeling spatially resolved light absorption in the vapor cell. The model accounts for the spatial distribution of spin polarization in the pump-light interaction volume, density-dependent relaxation rates, wall-induced relaxation, and polarization diffusion, and is implemented within a finite-element framework. Compared to the conventional Lambert-Beer law, which assumes one-dimensional homogeneity, our approach captures the full three-dimensional density and polarization distribution, significantly improving the accuracy of light absorption modeling. The resulting absorption-density maps are used to train a feedforward neural network, yielding a high-precision estimator for atomic density fluctuations. This estimator enables the construction of a decoupling equation that separates the density contribution from the FORA signal. Experimental validation shows that this method improves the bias instability at σ (100 s) of the gyroscope was improved by 73.1% compared to traditional platinum-resistance-based stabilization. The proposed framework is general and can be extended to other optical pumping-based sensors, such as optically pumped magnetometers.
The long-term bias stability of spin-exchange relaxation-free atomic co-magnetometers is significantly constrained by coupled opto-thermal fluctuations. Traditionally, random systemic offsets at the magnetic compensation point lead to inconsistent opto-thermal coupling, compromising the reproducibility of sensor performance. In this work, we propose a method to simultaneously decouple and suppress these primary drifts by precisely characterizing the physical null-point of the atomic ensemble. A combined compensation scheme, joining residual rotation angle alignment and transverse magnetic field adjustment, is implemented to isolate the sensor output from fluctuations in probe laser intensity and vapor cell temperature. Experimental results demonstrate that the sensitivities to temperature drifts and probe power fluctuations are suppressed simultaneously at the identified null-point by factors of 72 and 880, respectively. This approach establishes a stable zero point, which is expected to significantly enhance sensor reproducibility and stability without sacrificing fundamental sensing performance.