Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Magnetic field camera for zero-field conditions

Ronja Rasser, Peter Koß, Svenja Knappe, K. Buse

Published Jul 10, 2026• 0 citations
Publisher

Abstract

We present a zero-field optically pumped magnetometer using a 300 µm-thick rubidium vapor cell, which is read out with a camera. The camera enables the measurement system to take more than 7 000 individual measurement points in a circle of 4 mm diameter using a single vapor cell. Using the camera allows a spatial resolution of approximately 40 µm, which is limited by the quality of the optical signal. The measurement of a dynamic magnetic-field gradient, oscillating with a frequency of 130 Hz, confirms that the magnetic-field camera can record time-dependent magnetic field patterns.

DOI
10.1364/oe.597712

Related papers

Towards a multi-channel zero-field optically pumped magnetometer for imaging

Ronja Rasser, Peter A. Koss, Svenja A. Knappe +1 more

Abstract We present a design for a multi-channel optically pumped zero-field magnetometer utilizing a 200-μm-thick Rubidium vapor cell. The vapor cell and its housing are designed to reduce the minimal distance between a magnetic sample and the sensing volume to about 1 mm, to optimize the effective spatial resolution. The thin vapor cell, filled with 2 atm of nitrogen as a buffer gas reduces the volume across which the magnetic field is averaged. The vapor cell is fully illuminated by a single laser beam, and the transmitted light is imaged onto a 4 x 4 photodiode array, allowing for simultaneous measurement of a magnetic field distribution with up to 16 channels. The performance of the magnetometer is studied for all channels. It is shown that the sensor can operate in the spin-exchange relaxation-free regime with a projected photon-shot noise limited noise floor of about 1 pT/Hz1/2 for a sensitive voxel size of approximately 600 μm x 600 μm x 200 μm.

EPJ Quantum Technology•Aug 13, 2025•2 citations

Free-induction-decay magnetic field imaging with a microfabricated Cs vapor cell

Dominic Hunter, Christopher Perrella, Allan McWilliam +7 more

Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N 2 ) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a 175 μ m diameter probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43 pT/Hz within a Nyquist limited bandwidth of 500 Hz. Furthermore, the sensor’s dynamic range exceeds the Earth’s field of approximately 50 μ T, which provides a framework for magnetic field imaging in unshielded environments.

arXiv:2303.10915•Optics Express•Sep 11, 2023•16 citations

Picotesla optically pumped magnetometer using a laser-written vapor cell with sub-mm cross section

Andrea Zanoni, K. Mouloudakis, Michael C. D. Tayler +4 more

We demonstrate a sensitive optically pumped magnetometer using rubidium vapor and 0.75 amg of nitrogen buffer gas in a sub-mm-width sensing channel excavated by femtosecond laser writing followed by chemical etching. The channel is buried less than 1 mm below the surface of its fused silica host material, which also includes reservoir chambers and micro-strainer connections, to preserve a clean optical environment. Using a zero-field-resonance magnetometry strategy and a sensing volume of 2.25 mm3, we demonstrate a sensitivity of ≈1pT/Hz at 10 Hz. The device can be integrated with photonic structures and microfluidic channels with 3D versatility. Its sensitivity, bandwidth, and stand-off distance will enable detection of localized fields from magnetic nanoparticles and μL NMR samples.

Journal of Applied Physics•Oct 9, 2024•5 citations

Optimization and vectorization of a Mz-type optically-pumped Rubidium magnetometer

Zhengyu Su, Yang Li, Yongbiao Yang +3 more

Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a paraffin-coated anti-relaxation vapor cell. The system optimization and performance characterization were conducted inside a magnetic shield. Specifically, the pump light intensity and radio-frequency (RF) magnetic field were jointly optimized by using the linewidth-amplitude ratio as the core metric. Based on the frequency-domain noise spectrum, the sensitivity in open-loop mode was measured to be approximately 30.8 pT/Hz^{1/2}. Furthermore, a closed-loop feedback locking technique was applied, reducing the measured noise floor under the tested conditions and improving the sensitivity to 22.9 pT/Hz^{1/2}, with a measured -3 dB bandwidth of 123 Hz. The dynamic characteristics were evaluated via magnetic-field step response, showing that the system could track magnetic-field changes stably under closed-loop operation. Finally, by using tri-axial modulation and frequency-domain demodulation, we overcame the scalar measurement limitation of traditional Mz magnetometers. This work realizes vector magnetic field detection and provides a technical basis for applications such as geomagnetic navigation and magnetic anomaly detection.

arXiv:2604.02884•Apr 3, 2026•0 citations

Optimization and vectorization of an Mz-type optically pumped rubidium magnetometer

Zhengyu Su, Yang Li, Yongbiao Yang +3 more

Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a paraffin-coated anti-relaxation vapor cell. The system optimization and performance characterization were conducted inside a magnetic shield. Specifically, the pump light intensity and radio-frequency (RF) magnetic field were jointly optimized by using the linewidth-amplitude ratio as the core metric. Based on the frequency-domain noise spectrum, the sensitivity in open-loop mode was measured to be approximately 30.8pT/Hz 1/2 . Furthermore, a closed-loop feedback locking technique was applied, reducing the measured noise floor under the tested conditions and improving the sensitivity to 22.9pT/Hz 1/2 , with a measured −3dB bandwidth of 123 Hz. The dynamic characteristics were evaluated via magnetic-field step response, showing that the system could track magnetic-field changes stably under closed-loop operation. Finally, by using tri-axial modulation and frequency-domain demodulation, we overcame the scalar measurement limitation of traditional Mz magnetometers. This work realizes vector magnetic field detection and provides a technical basis for applications such as geomagnetic navigation and magnetic anomaly detection.

Journal of the Optical Society of America B•Jun 24, 2026•1 citation

High spatial resolution multi-channel optically pumped atomic magnetometer based on a spatial light modulator

Xiujie Fang, Kai Wei, Tian Zhao +5 more

Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz 1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.

Optics Express•Aug 14, 2020•46 citations
We present a zero-field optically pumped magnetometer using a 300 µm-thick rubidium vapor cell, which is read out with a camera. The camera enables the measurement system to take more than 7 000 individual measurement points in a circle of 4 mm diameter using a single vapor cell. Using the camera allows a spatial resolution of approximately 40 µm, which is limited by the quality of the optical signal. The measurement of a dynamic magnetic-field gradient, oscillating with a frequency of 130 Hz, confirms that the magnetic-field camera can record time-dependent magnetic field patterns.
Abstract We present a design for a multi-channel optically pumped zero-field magnetometer utilizing a 200-μm-thick Rubidium vapor cell. The vapor cell and its housing are designed to reduce the minimal distance between a magnetic sample and the sensing volume to about 1 mm, to optimize the effective spatial resolution. The thin vapor cell, filled with 2 atm of nitrogen as a buffer gas reduces the volume across which the magnetic field is averaged. The vapor cell is fully illuminated by a single laser beam, and the transmitted light is imaged onto a 4 x 4 photodiode array, allowing for simultaneous measurement of a magnetic field distribution with up to 16 channels. The performance of the magnetometer is studied for all channels. It is shown that the sensor can operate in the spin-exchange relaxation-free regime with a projected photon-shot noise limited noise floor of about 1 pT/Hz1/2 for a sensitive voxel size of approximately 600 μm x 600 μm x 200 μm.
Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N 2 ) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a 175 μ m diameter probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43 pT/Hz within a Nyquist limited bandwidth of 500 Hz. Furthermore, the sensor’s dynamic range exceeds the Earth’s field of approximately 50 μ T, which provides a framework for magnetic field imaging in unshielded environments.
We demonstrate a sensitive optically pumped magnetometer using rubidium vapor and 0.75 amg of nitrogen buffer gas in a sub-mm-width sensing channel excavated by femtosecond laser writing followed by chemical etching. The channel is buried less than 1 mm below the surface of its fused silica host material, which also includes reservoir chambers and micro-strainer connections, to preserve a clean optical environment. Using a zero-field-resonance magnetometry strategy and a sensing volume of 2.25 mm3, we demonstrate a sensitivity of ≈1pT/Hz at 10 Hz. The device can be integrated with photonic structures and microfluidic channels with 3D versatility. Its sensitivity, bandwidth, and stand-off distance will enable detection of localized fields from magnetic nanoparticles and μL NMR samples.
Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a paraffin-coated anti-relaxation vapor cell. The system optimization and performance characterization were conducted inside a magnetic shield. Specifically, the pump light intensity and radio-frequency (RF) magnetic field were jointly optimized by using the linewidth-amplitude ratio as the core metric. Based on the frequency-domain noise spectrum, the sensitivity in open-loop mode was measured to be approximately 30.8 pT/Hz^{1/2}. Furthermore, a closed-loop feedback locking technique was applied, reducing the measured noise floor under the tested conditions and improving the sensitivity to 22.9 pT/Hz^{1/2}, with a measured -3 dB bandwidth of 123 Hz. The dynamic characteristics were evaluated via magnetic-field step response, showing that the system could track magnetic-field changes stably under closed-loop operation. Finally, by using tri-axial modulation and frequency-domain demodulation, we overcame the scalar measurement limitation of traditional Mz magnetometers. This work realizes vector magnetic field detection and provides a technical basis for applications such as geomagnetic navigation and magnetic anomaly detection.
Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a paraffin-coated anti-relaxation vapor cell. The system optimization and performance characterization were conducted inside a magnetic shield. Specifically, the pump light intensity and radio-frequency (RF) magnetic field were jointly optimized by using the linewidth-amplitude ratio as the core metric. Based on the frequency-domain noise spectrum, the sensitivity in open-loop mode was measured to be approximately 30.8pT/Hz 1/2 . Furthermore, a closed-loop feedback locking technique was applied, reducing the measured noise floor under the tested conditions and improving the sensitivity to 22.9pT/Hz 1/2 , with a measured −3dB bandwidth of 123 Hz. The dynamic characteristics were evaluated via magnetic-field step response, showing that the system could track magnetic-field changes stably under closed-loop operation. Finally, by using tri-axial modulation and frequency-domain demodulation, we overcame the scalar measurement limitation of traditional Mz magnetometers. This work realizes vector magnetic field detection and provides a technical basis for applications such as geomagnetic navigation and magnetic anomaly detection.
Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz 1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.