Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Instrumentation and Measurement

Aperture-Integrated Biplanar Coil Based on an Improved Target-Field Method for Chip-Scale Magnetometer

Gen Hu, Jixi Lu, Lu Liu, Peng Zhou, Jinsheng Hu, Zihua Liang, Mao Ye

Published Jan 1, 2026• 1 citation
Publisher

Abstract

In recent years, nanofabrication technology is accelerating the miniaturization of atomic magnetometers, which is attracting widespread interest due to emerging applications in magnetocardiography and magnetoencephalography. However, it is challenging for CMOS-compatible magnetic coils to preserve the necessary optical aperture for pumping incidence, hindering further integration of the magnetometer to chip-scale. This article proposes an improved target-field method for the design of aperture-integrated biplanar coils tailored for microintegrated atomic magnetometers. Two stream functions with different side lengths and shared basis-function coefficients are predefined, and their difference is used to construct a new stream function for coil design. A 3-mm-diameter optical aperture is designed on the coil plane while maintaining high-magnetic-field uniformity. The proposed coils are fabricated through a CMOS-compatible process, and a miniaturized single-beam atomic magnetometer is constructed by combining our device with a 4-mm Rb vapor cell. Experimental results show that the noise floor of 25 fT/$\mathrm{Hz}^{\mathrm {1/2}}$is achieved with pumping light directly propagating through the optical aperture. Compared with a conventional Helmholtz coil, the maximum magnetic-field inhomogeneity is reduced from 10.7% to 2.9%. Our method is promising for on-cell integration of multiple magnetic-field coils, which pave the way for further miniaturization of chip-scale atomic magnetometer systems.

DOI
10.1109/tim.2026.3704269

Related papers

Integrated optical probing scheme enabled by localized‐interference metasurface for chip‐scale atomic magnetometer

Jinsheng Hu, Zihua Liang, Peng Zhou +3 more

Abstract Emerging miniaturized atomic sensors such as optically pumped magnetometers (OPMs) have attracted widespread interest due to their application in high‐spatial‐resolution biomagnetism imaging. While optical probing systems in conventional OPMs require bulk optical devices including linear polarizers and lenses for polarization conversion and wavefront shaping, which are challenging for chip‐scale integration. In this study, an integrated optical probing scheme based on localized‐interference metasurface for chip‐scale OPM is developed. Our monolithic metasurface allows tailorable linear polarization conversion and wavefront manipulation. Two silicon‐based metasurfaces namely meta‐polarizer and meta‐polarizer‐lens are fabricated and characterized, with maximum transmission efficiency and extinction ratio (ER) of 86.29 % and 14.2 dB for the meta‐polarizer as well as focusing efficiency and ER of 72.79 % and 6.4 dB for the meta‐polarizer‐lens, respectively. A miniaturized vapor cell with 4 × 4 × 4 mm 3 dimension containing 87 Rb and N 2 is combined with the meta‐polarizer to construct a compact zero‐field resonance OPM for proof of concept. The sensitivity of this sensor reaches approximately 9 fT/Hz 1/2 with a dynamic range near zero magnetic field of about ±2.3 nT. This study provides a promising solution for chip‐scale optical probing, which holds potential for the development of chip‐integrated OPMs as well as other advanced atomic devices where the integration of optical probing system is expected.

Nanophotonics•Sep 25, 2024•15 citations

Miniaturized atomic magnetometer employing pump-beam modulation

Ziqian Yue, Junjian Tang, Yueyang Zhai

Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).

Advanced Sensor Systems and Applications•Oct 11, 2024•0 citations

Meta-Polarizer-Lens Based Integrated Optical Probing Scheme for Atomic Magnetometer

Longkun Yu, Jinsheng Hu, Nan Li +3 more

Optically pumped magnetometers (OPMs) have undergone rapid development in recent years. The optical probing system, which plays a crucial role in interrogating quantum state of atoms under external perturbations, is an essential component in OPMs. However, conventional optical probing schemes rely on bulky optical components and tedious adjustment procedures, which hinder their applications in portable or compact scenarios. In this study, a method has been proposed in order to overcome these limitations by a metasurface, which is based on localized - interference effects. With the metasurface, we can simultaneously convert any incident polarized light into linearly polarized light and manipulate its wavefront. It achieves a maximum transmission efficiency of 91.7 % and a focusing efficiency of 91.3 %. Since the fabrication process of our metasurface is compatible with current complementary-metal-oxide-semiconductor (CMOS) fabrication technology, it can be integrated with a vapor cell, which is the core sensing element for many advanced atomic devices. Our study proposes an optical probing scheme suitable for chip-scale OPMs, and laying the foundation for the mass production of other chip-scale atomic devices.

IEEE Optoelectronics Global Conference (OGC)•Sep 9, 2025•0 citations

Chip-Scale Single-Beam Atomic Magnetometer Enabled by Spin-Selective Interference Meta-Optics

Jinsheng Hu, Zihua Liang, Peng Zhou +3 more

Emerging atomic magnetometers (AMs) are among the most advanced sensors for detecting and characterizing magnetic fields. Recently, there has been growing interest in the miniaturization and integration of AMs due to the urgent demand for portability and compactness in various fields such as biomagnetism imaging. While conventional AMs require a bulky setup of optical devices for the pumping and optical readout of atomic spin, here, a novel chip-scale single-beam AM scheme is proposed by leveraging extreme transmissive circular polarization dichroism (TCPD) and geometric phase manipulation of spin-selective interference meta-optics. This is achieved through silicon-based metasurfaces that enable the realization of arbitrary-to-circular polarization conversion and wavefront modulation within a monolithic chip at Rb D1 transition wavelength (λ = 795 nm). Two spin-selective interference metasurfaces, i.e., meta-circular-polarizer (MCP) and meta-circular-polarizer-lens (MCPL), are fabricated and characterized, with a measured TCPD of 0.68 for the MCP as well as focusing efficiency and TCPD of around 70.67% and 0.69 for the MCPL, respectively. As a proof of concept, a 4 × 4 × 4 mm 3 Rb vapor cell is combined with our metasurface to construct a miniaturized single-beam AM. The sensitivity of our compact metasurface-based system is about 15 fT/Hz 1/2, with a dynamic range near zero-field of ± 2.2 nT. We envision that this work could facilitate the development of burgeoning chip-scale quantum sensors, which hold great potential for high-spatial-resolution biomagnetic imaging, on-chip nuclear magnetic resonance, and so forth.

ACS Photonics•Dec 20, 2024•19 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•74 citations

In Situ Study of the Magnetic Field Gradient Produced by a Miniature Bi-Planar Coil for Chip-Scale Atomic Devices

Yao Chen, Jiyang Wang, Ning Zhang +6 more

The miniaturization of quantum sensors is a popular trend for the development of quantum technology. One of the key components of these sensors is a coil which is used for spin modulation and manipulation. The bi-planar coils have the advantage of producing three-dimensional magnetic fields with only two planes of current confinement, whereas the traditional Helmholtz coils require three-dimensional current distribution. Thus, the bi-planar coils are compatible with the current micro-fabrication process and are quite suitable for the compact design of the chip-scale atomic devices that require stable or modulated magnetic fields. This paper presents a design of a miniature bi-planar coil. Both the magnetic fields produced by the coils and their inhomogeneities were designed theoretically. The magnetic field gradient is a crucial parameter for the coils, especially for generating magnetic fields in very small areas. We used a NMR (Nuclear Magnetic Resonance) method based on the relaxation of 131Xe nuclear spins to measure the magnetic field gradient in situ. This is the first time that the field inhomogeneities of the field of such small bi-planar coils have been measured. Our results indicate that the designed gradient caused error is 0.08 for the By and the Bx coils, and the measured gradient caused error using the nuclear spin relaxation method is 0.09±0.02, suggesting that our method is suitable for measuring gradients. Due to the poor sensitivity of our magnetometer under a large Bz bias field, we could not measure the Bz magnetic field gradient. Our method also helps to improve the gradients of the miniature bi-planar coil design, which is critical for chip-scale atomic devices.

Micromachines•Oct 26, 2023•5 citations
In recent years, nanofabrication technology is accelerating the miniaturization of atomic magnetometers, which is attracting widespread interest due to emerging applications in magnetocardiography and magnetoencephalography. However, it is challenging for CMOS-compatible magnetic coils to preserve the necessary optical aperture for pumping incidence, hindering further integration of the magnetometer to chip-scale. This article proposes an improved target-field method for the design of aperture-integrated biplanar coils tailored for microintegrated atomic magnetometers. Two stream functions with different side lengths and shared basis-function coefficients are predefined, and their difference is used to construct a new stream function for coil design. A 3-mm-diameter optical aperture is designed on the coil plane while maintaining high-magnetic-field uniformity. The proposed coils are fabricated through a CMOS-compatible process, and a miniaturized single-beam atomic magnetometer is constructed by combining our device with a 4-mm Rb vapor cell. Experimental results show that the noise floor of 25 fT/Hz1/2\mathrm{Hz}^{\mathrm {1/2}}Hz1/2is achieved with pumping light directly propagating through the optical aperture. Compared with a conventional Helmholtz coil, the maximum magnetic-field inhomogeneity is reduced from 10.7% to 2.9%. Our method is promising for on-cell integration of multiple magnetic-field coils, which pave the way for further miniaturization of chip-scale atomic magnetometer systems.
Abstract Emerging miniaturized atomic sensors such as optically pumped magnetometers (OPMs) have attracted widespread interest due to their application in high‐spatial‐resolution biomagnetism imaging. While optical probing systems in conventional OPMs require bulk optical devices including linear polarizers and lenses for polarization conversion and wavefront shaping, which are challenging for chip‐scale integration. In this study, an integrated optical probing scheme based on localized‐interference metasurface for chip‐scale OPM is developed. Our monolithic metasurface allows tailorable linear polarization conversion and wavefront manipulation. Two silicon‐based metasurfaces namely meta‐polarizer and meta‐polarizer‐lens are fabricated and characterized, with maximum transmission efficiency and extinction ratio (ER) of 86.29 % and 14.2 dB for the meta‐polarizer as well as focusing efficiency and ER of 72.79 % and 6.4 dB for the meta‐polarizer‐lens, respectively. A miniaturized vapor cell with 4 × 4 × 4 mm 3 dimension containing 87 Rb and N 2 is combined with the meta‐polarizer to construct a compact zero‐field resonance OPM for proof of concept. The sensitivity of this sensor reaches approximately 9 fT/Hz 1/2 with a dynamic range near zero magnetic field of about ±2.3 nT. This study provides a promising solution for chip‐scale optical probing, which holds potential for the development of chip‐integrated OPMs as well as other advanced atomic devices where the integration of optical probing system is expected.
Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).
Optically pumped magnetometers (OPMs) have undergone rapid development in recent years. The optical probing system, which plays a crucial role in interrogating quantum state of atoms under external perturbations, is an essential component in OPMs. However, conventional optical probing schemes rely on bulky optical components and tedious adjustment procedures, which hinder their applications in portable or compact scenarios. In this study, a method has been proposed in order to overcome these limitations by a metasurface, which is based on localized - interference effects. With the metasurface, we can simultaneously convert any incident polarized light into linearly polarized light and manipulate its wavefront. It achieves a maximum transmission efficiency of 91.7 % and a focusing efficiency of 91.3 %. Since the fabrication process of our metasurface is compatible with current complementary-metal-oxide-semiconductor (CMOS) fabrication technology, it can be integrated with a vapor cell, which is the core sensing element for many advanced atomic devices. Our study proposes an optical probing scheme suitable for chip-scale OPMs, and laying the foundation for the mass production of other chip-scale atomic devices.
Emerging atomic magnetometers (AMs) are among the most advanced sensors for detecting and characterizing magnetic fields. Recently, there has been growing interest in the miniaturization and integration of AMs due to the urgent demand for portability and compactness in various fields such as biomagnetism imaging. While conventional AMs require a bulky setup of optical devices for the pumping and optical readout of atomic spin, here, a novel chip-scale single-beam AM scheme is proposed by leveraging extreme transmissive circular polarization dichroism (TCPD) and geometric phase manipulation of spin-selective interference meta-optics. This is achieved through silicon-based metasurfaces that enable the realization of arbitrary-to-circular polarization conversion and wavefront modulation within a monolithic chip at Rb D1 transition wavelength (λ = 795 nm). Two spin-selective interference metasurfaces, i.e., meta-circular-polarizer (MCP) and meta-circular-polarizer-lens (MCPL), are fabricated and characterized, with a measured TCPD of 0.68 for the MCP as well as focusing efficiency and TCPD of around 70.67% and 0.69 for the MCPL, respectively. As a proof of concept, a 4 × 4 × 4 mm 3 Rb vapor cell is combined with our metasurface to construct a miniaturized single-beam AM. The sensitivity of our compact metasurface-based system is about 15 fT/Hz 1/2, with a dynamic range near zero-field of ± 2.2 nT. We envision that this work could facilitate the development of burgeoning chip-scale quantum sensors, which hold great potential for high-spatial-resolution biomagnetic imaging, on-chip nuclear magnetic resonance, and so forth.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
The miniaturization of quantum sensors is a popular trend for the development of quantum technology. One of the key components of these sensors is a coil which is used for spin modulation and manipulation. The bi-planar coils have the advantage of producing three-dimensional magnetic fields with only two planes of current confinement, whereas the traditional Helmholtz coils require three-dimensional current distribution. Thus, the bi-planar coils are compatible with the current micro-fabrication process and are quite suitable for the compact design of the chip-scale atomic devices that require stable or modulated magnetic fields. This paper presents a design of a miniature bi-planar coil. Both the magnetic fields produced by the coils and their inhomogeneities were designed theoretically. The magnetic field gradient is a crucial parameter for the coils, especially for generating magnetic fields in very small areas. We used a NMR (Nuclear Magnetic Resonance) method based on the relaxation of 131Xe nuclear spins to measure the magnetic field gradient in situ. This is the first time that the field inhomogeneities of the field of such small bi-planar coils have been measured. Our results indicate that the designed gradient caused error is 0.08 for the By and the Bx coils, and the measured gradient caused error using the nuclear spin relaxation method is 0.09±0.02, suggesting that our method is suitable for measuring gradients. Due to the poor sensitivity of our magnetometer under a large Bz bias field, we could not measure the Bz magnetic field gradient. Our method also helps to improve the gradients of the miniature bi-planar coil design, which is critical for chip-scale atomic devices.