Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Probing coherence properties of shallow implanted NV ensembles under different oxygen terminations

Jens Fuhrmann, Johannes Lang, Jochen Scharpf, Nico Striegler, Thomas Unden, Philipp Neumann, Joachim Bansmann, Fedor Jelezko

Published Dec 10, 2024• 0 citations
Publisher

Abstract

Nitrogen vacancy (NV) color centers in diamond have shown great potential for various applications in quantum technology due to their long coherence times, high sensitivity to magnetic fields and atomic scale resolution. However, one major challenge in utilizing near surface NV centers is the decoherence caused by spins and charges fluctuating on the surface, which affects the spin properties of the sensors. To reduce the induced noise, various oxygen surface treatments such as low power oxygen plasma treatment and annealing under oxygen atmosphere have been explored to terminate the diamond surface and reduce its impact on NV coherence. We showed that the NV center’s coherence time can be enhanced up to a factor of 3 over a large spectral range of noise. Double electron–electron resonance measurements revealed an extra source of decoherence, scaling similarly as the P1 spin bath. The improvement in coherence times is accompanied with an increase in measured ketone/ether content and reduction of sp2 signal in x-ray photoelectron spectroscopy measurements. Finally we compared the performance of different NV ensembles and surface treatments for sensing external proton spins. The oxygen annealing is an effective procedure of enhancing the spin coherence times and reducing broad band spin noise experienced by shallow implanted ensemble NV centers in diamond.

DOI
10.18725/oparu-60185

Related papers

Probing coherence properties of shallow implanted NV ensembles under different oxygen terminations

Jens Fuhrmann, Johannes Lang, Jochen Scharpf +5 more

Abstract Nitrogen vacancy (NV) color centers in diamond have shown great potential for various applications in quantum technology due to their long coherence times, high sensitivity to magnetic fields and atomic scale resolution. However, one major challenge in utilizing near surface NV centers is the decoherence caused by spins and charges fluctuating on the surface, which affects the spin properties of the sensors. To reduce the induced noise, various oxygen surface treatments such as low power oxygen plasma treatment and annealing under oxygen atmosphere have been explored to terminate the diamond surface and reduce its impact on NV coherence. We showed that the NV center’s coherence time can be enhanced up to a factor of 3 over a large spectral range of noise. Double electron–electron resonance measurements revealed an extra source of decoherence, scaling similarly as the P1 spin bath. The improvement in coherence times is accompanied with an increase in measured ketone/ether content and reduction of sp 2 signal in x-ray photoelectron spectroscopy measurements. Finally we compared the performance of different NV ensembles and surface treatments for sensing external proton spins. The oxygen annealing is an effective procedure of enhancing the spin coherence times and reducing broad band spin noise experienced by shallow implanted ensemble NV centers in diamond.

Materials for Quantum Technology•Nov 15, 2024•11 citations

Enhancement of Coherence Times of Individual Shallow NV Center due to Ozone Treatment

Jessica fernanda Da Silva Barbosa, Angelika Kaiser, Alma Beatrice Sergi +6 more

ABSTRACT Shallow nitrogen vacancy (NV) centers with long coherence times are promising candidates for applications in areas such as quantum computing and quantum sensing. However, as the NVs are only a few nanometers below the diamond's surface, it is a challenge to remove the different decoherence sources related to the surface, e.g., charge fluctuations and magnetic impurities. Here, the effect of ozone treatment on the chemical composition of diamond surfaces was correlated with its impact on the spin properties of the same individual shallow NV (depth < 20 nm) by comparing its coherence times, Ramsey and Hahn Echo (T 2 ), before and after the treatment. X‐ray photoelectron spectroscopy (XPS) shows a reduction in sp 2 bonds, and it was reported that an enhancement of the coherence times up to a factor of 3. Additionally, we investigate the effects of Ozone treatment on random single NVs engineered to have a depth of ∼30 nm, where an enhancement up to a factor of 10 on and up to a factor of 3 on T 2 have been observed.

Advanced Quantum Technologies•Apr 1, 2026•1 citation

A coherence-protection scheme for quantum sensors based on ultra-shallow single nitrogen-vacancy centers in diamond

Anton Pershin, András Tárkányi, Vladimir Verkhovlyuk +2 more

High spatial resolution quantum sensing of near-surface nitrogen vacancy (NV) centers in diamond has enabled detection of magnetic, electrical, and thermal signals at the nanoscale. At depths of just a few nanometers, NV centers serve as localized quantum probes for external spins or low-dimensional materials, but their proximity to the surface also enhances decoherence caused by fluctuating nuclear spins. While advances in surface engineering have stabilized the charge state of NV centers at depths of tens of nanometers, achieving both ultra-shallow implantation (0.5-2 nm) and long-term spin coherence remains a central challenge. In this work, we show using first-principles modeling that, by exploiting the interaction of surface-induced strain and weak dc magnetic fields, the spin coherence times of 1-nm-deep NV centers can be greatly improved near the spin-phonon-confined regime at room temperature in 12C-rich diamonds. We also demonstrate that this protocol benefits ~ 10-nm-deep NV centers in natural diamond, enabling vector magnetometry at the nanoscale. Shallow NV centers in diamond are advantageous for quantum sensing but suffer from surface magnetic noise. Using first-principles simulations supported by experiments, the authors show that a combination of small magnetic fields and surface strain can significantly enhance spin coherence of 1 nm-deep NV centers.

arXiv:2501.00180•Nature Communications•Nov 6, 2025•9 citations

Charge state stabilization of shallow nitrogen vacancy centers in diamond by oxygen surface modification

Hayate Yamano, Sora Kawai, Kanami Kato +13 more

Abstract We investigated the charge state stability and coherence properties of near-surface single nitrogen vacancy (NV) centers in 12 C-enriched diamond for potential use in nanoscale magnetic field sensing applications. The stability of charge states in negatively charged NV centers (NV − ) was evaluated using one of the pulsed optically detected magnetic resonance measurements, Rabi oscillation measurements. During the accumulation of Rabi oscillations, an unstable shallow NV − was converted to a neutral state. As a result, the contrast of Rabi oscillations degraded, depending on charge state stability. We stabilized the NV − state of very shallow NV centers (∼2.6 ± 1.1 nm from the surface) created by 1.2 keV nitrogen ion implantation by diamond surface modification, UV/ozone exposure, and oxygen annealing. This improvement indicates that we can suppress the upward surface band bending and surface potential fluctuations through Fermi level pinning originating from oxygen-terminated diamond surfaces.

Japanese Journal of Applied Physics•Mar 23, 2017•69 citations

Doping optimization of charge state stability for shallow nitrogen-vacancy center ensembles in HPHT diamonds

Qin Wu, Die Fang, Yu Ma +9 more

Since nitrogen-vacancy (NV) centers in diamond have emerged as crucial quantum sensors in physics and biology, the massive preparation of high-quality and high-concentration shallow NV center samples has become urgent and demanding. As NV centers approach the surface and their concentration increases, charge state instability can degrade coherence and introduce additional noise. This problem is further complicated in high-pressure and high-temperature (HPHT) diamonds due to the presence of unclear impurities and inhomogeneous strain. Through optically detected magnetic resonance testing on various implanted samples, we analyzed the spin and charge state properties of shallow NV center ensembles. Our results reveal that the doping dose significantly influences the quantity of NV−, charge, and charge stability. Our findings indicate that over-implanting nitrogen as electron donors before starting graphitization helps stabilize the charge environment of the shallow NV center ensembles. By controlling the nitrogen ion implantation dose, we optimized charge state stability under photoionization and prepared high-quality NV center ensemble samples in HPHT diamonds at the optimal implantation dose range of 2×1013–8×1013 ions/cm2. This method, which relies solely on nitrogen ion implantation and annealing on HPHT diamond, significantly reduces the cost of sensor samples, greatly benefiting the promotion of quantum sensing.

Applied Physics Letters•Jun 16, 2025•1 citation

Origins of Diamond Surface Noise Probed by Correlating Single-Spin Measurements with Surface Spectroscopy

Sorawis Sangtawesin, Bo Dwyer, Srikanth J. Srinivasan +15 more

The nitrogen-vacancy (NV) center in diamond exhibits spin-dependent fluorescence and long spin coherence times under ambient conditions, enabling applications in quantum information processing and sensing. NV centers near the surface can have strong interactions with external materials and spins, enabling new forms of nanoscale spectroscopy. However, NV spin coherence degrades within 100 nm of the surface, suggesting that diamond surfaces are plagued with ubiquitous defects. Prior work on characterizing near-surface noise has primarily relied on using NV centers themselves as probes; while this has the advantage of exquisite sensitivity, it provides only indirect information about the origin of the noise. Here we demonstrate that surface spectroscopy methods and single-spin measurements can be used as complementary diagnostics to understand sources of noise. We find that surface morphology is crucial for realizing reproducible chemical termination, and use this insight to achieve a highly ordered, oxygen-terminated surface with suppressed noise. We observe NV centers within 10 nm of the surface with coherence times extended by an order of magnitude.

•Nov 2, 2024•210 citations
Nitrogen vacancy (NV) color centers in diamond have shown great potential for various applications in quantum technology due to their long coherence times, high sensitivity to magnetic fields and atomic scale resolution. However, one major challenge in utilizing near surface NV centers is the decoherence caused by spins and charges fluctuating on the surface, which affects the spin properties of the sensors. To reduce the induced noise, various oxygen surface treatments such as low power oxygen plasma treatment and annealing under oxygen atmosphere have been explored to terminate the diamond surface and reduce its impact on NV coherence. We showed that the NV center’s coherence time can be enhanced up to a factor of 3 over a large spectral range of noise. Double electron–electron resonance measurements revealed an extra source of decoherence, scaling similarly as the P1 spin bath. The improvement in coherence times is accompanied with an increase in measured ketone/ether content and reduction of sp2 signal in x-ray photoelectron spectroscopy measurements. Finally we compared the performance of different NV ensembles and surface treatments for sensing external proton spins. The oxygen annealing is an effective procedure of enhancing the spin coherence times and reducing broad band spin noise experienced by shallow implanted ensemble NV centers in diamond.
Abstract Nitrogen vacancy (NV) color centers in diamond have shown great potential for various applications in quantum technology due to their long coherence times, high sensitivity to magnetic fields and atomic scale resolution. However, one major challenge in utilizing near surface NV centers is the decoherence caused by spins and charges fluctuating on the surface, which affects the spin properties of the sensors. To reduce the induced noise, various oxygen surface treatments such as low power oxygen plasma treatment and annealing under oxygen atmosphere have been explored to terminate the diamond surface and reduce its impact on NV coherence. We showed that the NV center’s coherence time can be enhanced up to a factor of 3 over a large spectral range of noise. Double electron–electron resonance measurements revealed an extra source of decoherence, scaling similarly as the P1 spin bath. The improvement in coherence times is accompanied with an increase in measured ketone/ether content and reduction of sp 2 signal in x-ray photoelectron spectroscopy measurements. Finally we compared the performance of different NV ensembles and surface treatments for sensing external proton spins. The oxygen annealing is an effective procedure of enhancing the spin coherence times and reducing broad band spin noise experienced by shallow implanted ensemble NV centers in diamond.
ABSTRACT Shallow nitrogen vacancy (NV) centers with long coherence times are promising candidates for applications in areas such as quantum computing and quantum sensing. However, as the NVs are only a few nanometers below the diamond's surface, it is a challenge to remove the different decoherence sources related to the surface, e.g., charge fluctuations and magnetic impurities. Here, the effect of ozone treatment on the chemical composition of diamond surfaces was correlated with its impact on the spin properties of the same individual shallow NV (depth < 20 nm) by comparing its coherence times, Ramsey and Hahn Echo (T 2 ), before and after the treatment. X‐ray photoelectron spectroscopy (XPS) shows a reduction in sp 2 bonds, and it was reported that an enhancement of the coherence times up to a factor of 3. Additionally, we investigate the effects of Ozone treatment on random single NVs engineered to have a depth of ∼30 nm, where an enhancement up to a factor of 10 on and up to a factor of 3 on T 2 have been observed.
High spatial resolution quantum sensing of near-surface nitrogen vacancy (NV) centers in diamond has enabled detection of magnetic, electrical, and thermal signals at the nanoscale. At depths of just a few nanometers, NV centers serve as localized quantum probes for external spins or low-dimensional materials, but their proximity to the surface also enhances decoherence caused by fluctuating nuclear spins. While advances in surface engineering have stabilized the charge state of NV centers at depths of tens of nanometers, achieving both ultra-shallow implantation (0.5-2 nm) and long-term spin coherence remains a central challenge. In this work, we show using first-principles modeling that, by exploiting the interaction of surface-induced strain and weak dc magnetic fields, the spin coherence times of 1-nm-deep NV centers can be greatly improved near the spin-phonon-confined regime at room temperature in 12C-rich diamonds. We also demonstrate that this protocol benefits ~ 10-nm-deep NV centers in natural diamond, enabling vector magnetometry at the nanoscale. Shallow NV centers in diamond are advantageous for quantum sensing but suffer from surface magnetic noise. Using first-principles simulations supported by experiments, the authors show that a combination of small magnetic fields and surface strain can significantly enhance spin coherence of 1 nm-deep NV centers.
Abstract We investigated the charge state stability and coherence properties of near-surface single nitrogen vacancy (NV) centers in 12 C-enriched diamond for potential use in nanoscale magnetic field sensing applications. The stability of charge states in negatively charged NV centers (NV − ) was evaluated using one of the pulsed optically detected magnetic resonance measurements, Rabi oscillation measurements. During the accumulation of Rabi oscillations, an unstable shallow NV − was converted to a neutral state. As a result, the contrast of Rabi oscillations degraded, depending on charge state stability. We stabilized the NV − state of very shallow NV centers (∼2.6 ± 1.1 nm from the surface) created by 1.2 keV nitrogen ion implantation by diamond surface modification, UV/ozone exposure, and oxygen annealing. This improvement indicates that we can suppress the upward surface band bending and surface potential fluctuations through Fermi level pinning originating from oxygen-terminated diamond surfaces.
Since nitrogen-vacancy (NV) centers in diamond have emerged as crucial quantum sensors in physics and biology, the massive preparation of high-quality and high-concentration shallow NV center samples has become urgent and demanding. As NV centers approach the surface and their concentration increases, charge state instability can degrade coherence and introduce additional noise. This problem is further complicated in high-pressure and high-temperature (HPHT) diamonds due to the presence of unclear impurities and inhomogeneous strain. Through optically detected magnetic resonance testing on various implanted samples, we analyzed the spin and charge state properties of shallow NV center ensembles. Our results reveal that the doping dose significantly influences the quantity of NV−, charge, and charge stability. Our findings indicate that over-implanting nitrogen as electron donors before starting graphitization helps stabilize the charge environment of the shallow NV center ensembles. By controlling the nitrogen ion implantation dose, we optimized charge state stability under photoionization and prepared high-quality NV center ensemble samples in HPHT diamonds at the optimal implantation dose range of 2×1013–8×1013 ions/cm2. This method, which relies solely on nitrogen ion implantation and annealing on HPHT diamond, significantly reduces the cost of sensor samples, greatly benefiting the promotion of quantum sensing.
The nitrogen-vacancy (NV) center in diamond exhibits spin-dependent fluorescence and long spin coherence times under ambient conditions, enabling applications in quantum information processing and sensing. NV centers near the surface can have strong interactions with external materials and spins, enabling new forms of nanoscale spectroscopy. However, NV spin coherence degrades within 100 nm of the surface, suggesting that diamond surfaces are plagued with ubiquitous defects. Prior work on characterizing near-surface noise has primarily relied on using NV centers themselves as probes; while this has the advantage of exquisite sensitivity, it provides only indirect information about the origin of the noise. Here we demonstrate that surface spectroscopy methods and single-spin measurements can be used as complementary diagnostics to understand sources of noise. We find that surface morphology is crucial for realizing reproducible chemical termination, and use this insight to achieve a highly ordered, oxygen-terminated surface with suppressed noise. We observe NV centers within 10 nm of the surface with coherence times extended by an order of magnitude.