Optical and Photonic Microsystems: Technology and Applications

Integrated micro-optical detection system for ion-trap quantum computing

Lukas Uhlig, Gregor Büttel, Jennifer Ruskowski, Aniket Patra, Kenan Berisa, Jörg Martin, Steffen Kurth, Micha Haase, Christian Helke, S. Dreiner, Linda Cousin, Andreas Jansen, Nicolas Schierbaum, Matthias Prinz, Nathanael Jöhrmann, Danny Reuter, Bernhard Wunderle

Published May 28, 2026• 0 citations
Publisher

Abstract

We develop a micro-optical detection system for collecting the ultraviolet (UV) fluorescence of trapped ions using a microfabricated binary Fresnel lens, a pinhole, and a backside-illuminated (BSI) silicon photomultiplier (SiPM). To model the trapped ion, another pinhole with sub-micrometer diameter is employed. High detection efficiency is enabled by developing Fresnel lenses with high numerical aperture of up to 0.5 and the BSI SiPMs designed for a photon detection probability (PDP) of over 50% in the UV-regime, realized by a specific anti-reflection coating. Furthermore, this micro-optical system concept offers wavelength-selectivity and stray light filtering as important features for detecting the weak fluorescence signal. The performance of the micro-optical components was experimentally investigated and compared to simulations.

DOI
10.1117/12.3098178

Related papers

Demonstration of integrated microscale optics in surface-electrode ion traps

J True Merrill, Curtis Volin, David Landgren +10 more

In ion trap quantum information processing, efficient fluorescence collection is critical for fast, high-fidelity qubit detection and ion–photon entanglement. The expected size of future many-ion processors requires scalable light collection systems. We report on the development and testing of a microfabricated surface-electrode ion trap with an integrated high-numerical aperture (NA) micromirror for fluorescence collection. When coupled to a low-NA lens, the optical system is inherently scalable to large arrays of mirrors in a single device. We demonstrate the stable trapping and transport of 40 Ca + ions over a 0.63 NA micromirror and observe a factor of 1.9 enhancement of photon collection compared to the planar region of the trap.

arXiv:1105.4905•New Journal of Physics•Oct 4, 2011•62 citations

Micro-optical grayscale excitation lenses for atom and ion trapping.

David A. Scrymgeour

Designing and integrating micro-optical components into atom and ion traps are enabling steps toward miniaturizing trap dimensions in quantum computation applications.The micro-optic must have a high numerical aperture for precise illumination of the ion and should not introduce scatter.Due to the extreme optical efficiency requirements in trapped ion and atom-based quantum information processing, even slight losses from integrated micro-optics are detrimental.We have designed and fabricated aspheric micro-lenses through grayscale transfer into a fused silica in an effort to realize increased transmissive efficiency and decreased scatter compared to an equivalent diffractive optical element.The fabricated grayscale lens profile matched the desired lens profile well, and the measured and predicted optical performances were in good agreement.The pattern was transferred via coupled plasma reactive-ion etching smoothly into the fused silica with a RMS roughness ~35 nm.The micro-lens had a diameter of 88 um and 14.2 um sag, with an as-designed focal length of 149 um and spot diameter of 2.6 um.The maximum measured efficiency was ~80% (86% of theoretical, possibly due to rms roughness).This realized efficiency is superior to the equivalent diffractive lens efficiency, designed to the same use parameters.The grayscale approach demonstrated an increase in collection efficiency, at the desired optical focal length, providing the potential for further refinement.

•Aug 22, 2016•0 citations

Imaging of Trapped Ions with a Microfabricated Optic for Quantum Information Processing

Erik W. Streed, B. G. Norton, Andreas Jechow +2 more

Trapped ions are a leading system for realizing quantum information processing (QIP). Most of the technologies required for implementing large-scale trapped-ion QIP have been demonstrated, with one key exception: a massively parallel ion-photon interconnect. Arrays of microfabricated phase Fresnel lenses (PFL) are a promising interconnect solution that is readily integrated with ion trap arrays for large-scale QIP. Here we show the first imaging of trapped ions with a microfabricated in-vacuum PFL, demonstrating performance suitable for scalable QIP. A single ion fluorescence collection efficiency of 4.2±1.5% was observed. The depth of focus for the imaging system was 19.4±2.4 μm and the field of view was 140±20 μm. Our approach also provides an integrated solution for high-efficiency optical coupling in neutral atom and solid-state QIP architectures.

arXiv:1006.4192•Physical Review Letters•Jan 5, 2011•89 citations

Imaging trapped ions with an integrated microfabricated optic

Erik W. Streed, B. G. Norton, Till J. Weinhold +3 more

We have integrated a microfabricated phase Fresnel lens (PFL) with an ion trap and used it to image a 174Yb+ ion. The observed collection efficiency was 4.1± 1.3%, in agreement with a predicted performance of 4.6% based on optical characterization and suitable for use in quantum computing. A maximum signal to background scatter noise of 23±4 was measured near saturation intensity (s = 0.7). The depth of focus was 11 μm and the field of view in excess of 100 μm across.

AIP conference proceedings•Jan 1, 2011•0 citations

Integrated System Technologies for Modular Trapped Ion Quantum Information Processing

Stephen Crain

Although trapped ion technology is well-suited for quantum information science, scalability of the system remains one of the main challenges. One of the challenges associated with scaling the ion trap quantum computer is the ability to individually manipulate the increasing number of qubits. Using micro-mirrors fabricated with micro-electromechanical systems (MEMS) technology, laser beams are focused on individual ions in a linear chain and steer the focal point in two dimensions. Multiple single qubit gates are demonstrated on trapped 171Yb+ qubits and the gate performance is characterized using quantum state tomography. The system features negligible crosstalk to neighboring ions (< 3e-4), and switching speeds comparable to typical single qubit gate times (< 2 us). In a separate experiment, photons scattered from the 171Yb+ ion are coupled into an optical fiber with 63% efficiency using a high numerical aperture lens (0.6 NA). The coupled photons are directed to superconducting nanowire single photon detectors (SNSPD), which provide a higher detector efficiency (69%) compared to traditional photomultiplier tubes (35%). The total system photon collection efficiency is increased from 2.2% to 3.4%, which allows for fast state detection of the qubit. For a detection beam intensity of 11 mW/cm2, the average detection time is 23.7 us with 99.885(7)% detection fidelity. The technologies demonstrated in this thesis can be integrated to form a single quantum register with all of the necessary resources to perform local gates as well as high fidelity readout and provide a photon link to other systems.

•Jan 1, 2016•2 citations

Efficient fluorescence collection from trapped ions with an integrated spherical mirror

Gang Shu, Nathan Kurz, Matthew Dietrich +1 more

Efficient collection of fluorescence from trapped ions is crucial for quantum optics and quantum computing applications, specifically for qubit state detection and in generating single photons for ion-photon and remote ion entanglement. In a typical setup, only a few percent of the ion fluorescence is intercepted by the aperture of the imaging optics. We employ a simple metallic spherical mirror integrated with a linear Paul ion trap to achieve a photon collection efficiency of at least $10%$ from a single Ba${}^{+}$ ion. An aspheric corrector is used to reduce the aberrations caused by the mirror and achieve high image quality.

arXiv:0911.4958•Physical Review A•Apr 26, 2010•36 citations
We develop a micro-optical detection system for collecting the ultraviolet (UV) fluorescence of trapped ions using a microfabricated binary Fresnel lens, a pinhole, and a backside-illuminated (BSI) silicon photomultiplier (SiPM). To model the trapped ion, another pinhole with sub-micrometer diameter is employed. High detection efficiency is enabled by developing Fresnel lenses with high numerical aperture of up to 0.5 and the BSI SiPMs designed for a photon detection probability (PDP) of over 50% in the UV-regime, realized by a specific anti-reflection coating. Furthermore, this micro-optical system concept offers wavelength-selectivity and stray light filtering as important features for detecting the weak fluorescence signal. The performance of the micro-optical components was experimentally investigated and compared to simulations.
In ion trap quantum information processing, efficient fluorescence collection is critical for fast, high-fidelity qubit detection and ion–photon entanglement. The expected size of future many-ion processors requires scalable light collection systems. We report on the development and testing of a microfabricated surface-electrode ion trap with an integrated high-numerical aperture (NA) micromirror for fluorescence collection. When coupled to a low-NA lens, the optical system is inherently scalable to large arrays of mirrors in a single device. We demonstrate the stable trapping and transport of 40 Ca + ions over a 0.63 NA micromirror and observe a factor of 1.9 enhancement of photon collection compared to the planar region of the trap.
Designing and integrating micro-optical components into atom and ion traps are enabling steps toward miniaturizing trap dimensions in quantum computation applications.The micro-optic must have a high numerical aperture for precise illumination of the ion and should not introduce scatter.Due to the extreme optical efficiency requirements in trapped ion and atom-based quantum information processing, even slight losses from integrated micro-optics are detrimental.We have designed and fabricated aspheric micro-lenses through grayscale transfer into a fused silica in an effort to realize increased transmissive efficiency and decreased scatter compared to an equivalent diffractive optical element.The fabricated grayscale lens profile matched the desired lens profile well, and the measured and predicted optical performances were in good agreement.The pattern was transferred via coupled plasma reactive-ion etching smoothly into the fused silica with a RMS roughness ~35 nm.The micro-lens had a diameter of 88 um and 14.2 um sag, with an as-designed focal length of 149 um and spot diameter of 2.6 um.The maximum measured efficiency was ~80% (86% of theoretical, possibly due to rms roughness).This realized efficiency is superior to the equivalent diffractive lens efficiency, designed to the same use parameters.The grayscale approach demonstrated an increase in collection efficiency, at the desired optical focal length, providing the potential for further refinement.
Trapped ions are a leading system for realizing quantum information processing (QIP). Most of the technologies required for implementing large-scale trapped-ion QIP have been demonstrated, with one key exception: a massively parallel ion-photon interconnect. Arrays of microfabricated phase Fresnel lenses (PFL) are a promising interconnect solution that is readily integrated with ion trap arrays for large-scale QIP. Here we show the first imaging of trapped ions with a microfabricated in-vacuum PFL, demonstrating performance suitable for scalable QIP. A single ion fluorescence collection efficiency of 4.2±1.5% was observed. The depth of focus for the imaging system was 19.4±2.4 μm and the field of view was 140±20 μm. Our approach also provides an integrated solution for high-efficiency optical coupling in neutral atom and solid-state QIP architectures.
Although trapped ion technology is well-suited for quantum information science, scalability of the system remains one of the main challenges. One of the challenges associated with scaling the ion trap quantum computer is the ability to individually manipulate the increasing number of qubits. Using micro-mirrors fabricated with micro-electromechanical systems (MEMS) technology, laser beams are focused on individual ions in a linear chain and steer the focal point in two dimensions. Multiple single qubit gates are demonstrated on trapped 171Yb+ qubits and the gate performance is characterized using quantum state tomography. The system features negligible crosstalk to neighboring ions (< 3e-4), and switching speeds comparable to typical single qubit gate times (< 2 us). In a separate experiment, photons scattered from the 171Yb+ ion are coupled into an optical fiber with 63% efficiency using a high numerical aperture lens (0.6 NA). The coupled photons are directed to superconducting nanowire single photon detectors (SNSPD), which provide a higher detector efficiency (69%) compared to traditional photomultiplier tubes (35%). The total system photon collection efficiency is increased from 2.2% to 3.4%, which allows for fast state detection of the qubit. For a detection beam intensity of 11 mW/cm2, the average detection time is 23.7 us with 99.885(7)% detection fidelity. The technologies demonstrated in this thesis can be integrated to form a single quantum register with all of the necessary resources to perform local gates as well as high fidelity readout and provide a photon link to other systems.
Efficient collection of fluorescence from trapped ions is crucial for quantum optics and quantum computing applications, specifically for qubit state detection and in generating single photons for ion-photon and remote ion entanglement. In a typical setup, only a few percent of the ion fluorescence is intercepted by the aperture of the imaging optics. We employ a simple metallic spherical mirror integrated with a linear Paul ion trap to achieve a photon collection efficiency of at least 1010%10 from a single Ba+{}^{+}+ ion. An aspheric corrector is used to reduce the aberrations caused by the mirror and achieve high image quality.