Towards Ultra-High Vacuum Operation in a TEM for Quantum-Computer-Enhanced Electron Microscopy

Martino Zanetti, Dominik Hornof, Michael Stanislaus Seifner, Philipp Haslinger, Thomas Juffmann

Published Apr 20, 2026• 0 citations
Publisher

Abstract

Quantum electron microscopy is an emerging research field at the intersection of electron microscopy, quantum optics, and nanophotonics. Free electrons can serve as powerful quantum probes, on par with photons in their ability to carry and transfer quantum information, generate entanglement within and with a specimen, and reveal previously inaccessible details on nanoscale quantum phenomena [1]. However, quantum experiments are generally highly sensitive to decoherence arising from interactions with residual gas particles, making ultra-high vacuum (UHV) conditions sometimes essential. UHV environments are also required in transmission electron microscopes (TEMs) for the investigation of contamination-sensitive materials [2, 3]. In our project, we aim to combine a trapped-ion quantum computer with a TEM to realise Quantum-Computer-Enhanced Electron Microscopy (QCEM) (www.qcem.info). In this scheme, coherent interactions between free electrons and a trapped ion require vacuum conditions beyond the standard TEM operation [4]. Although UHV-TEM systems have previously been realised [2,3, 5-7], achieving base pressures in the 10⁻⁹ mbar range or better typically involves significant financial investment, long implementation times, and close collaboration with manufacturers. We present a cost-effective, minimally invasive modification to the vacuum system of a JEOL JEM-2100F to reduce the base pressure at the sample position to below 5 × 10⁻⁹ mbar. Our approach is to integrate two additional 50 L/s NEG-ion pumps mounted on flanges near the sample region, with no structural modifications to the microscope. The NEG pumps are integrated into the microscope workflow through controlled activation and regeneration cycles compatible with standard TEM operation. This work represents a practical step toward enabling the realisation of QCEM, and the concept enables a relatively rapid implementation at a moderate cost, which can, in principle, be adapted to any TEM that provides suitable flange access to the sample chamber.

DOI
10.34726/12107

Related papers

Vacuum assembly, atomic source development, and micromotion studies for a trapped Ba+ based quantum processor

Ali Khatai

Trapped-ions are one of the leading platforms for quantum information processing, due to their long coherence times and high-fidelity State Preparation and Measurement (SPAM) and gate operations. However, implementing a trapped-ion system with many desirable features such as Ultra-High-Vacuum (UHV), High-Optical-Access (HOA), and a high trapping probability presents significant technical challenges. These features are critical for enabling complex quantum simulation experiments, including simulations of spin-1/2 systems and beyond, by leveraging the multiple internal states of barium and tunable spin–spin interactions. High optical access is required to deliver tightly focused beams for site-resolved control and inter-ion coupling, while UHV conditions are essential for achieving long ion lifetimes necessary for stable, large-scale simulations. Achieving such optical access, which is vital for both coherent gate operations and high numerical aperture fluorescence collection, whilst maintaining vacuum integrity presents substantial engineering challenges. This thesis presents the construction of a vacuum chamber system intended for an individually addressable 16-qubit quantum processor based on barium-133 ions confined in a microfabricated surface-electrode ion trap. Although the complete processor has not yet been realized, the chamber has been assembled to support its future implementation. The microfabricated surface-electrode ion trap features ∼ 100 electrodes that require independent control of static voltages for precise tailoring of the confining electric potential. The experimental setup was designed to provide high optical access and to reach base pressures in the low 10^(−11) mbar range, thereby minimizing ion–background gas collisions. This is achieved by centrally mounting the trap within the vacuum chamber, a departure from conventional flange-mounted designs. To bring in-vacuum electrical connections to ∼ 100 trap electrodes, a custom implementation of an in-vacuum wire harness is described that enables reliable electrical connectivity to the centrally mounted surface electrode ion trap. The development of this wire harness enabled us to reach UHV with a pressure of ≈ 3 × 10^(−11) mbar. The successful development of this wire harness demonstrates that it is possible to create a UHV compatible wiring solution using commercially available components for a surface-electrode ion trap suspended at the center of the vacuum chamber. This centrally mounted design provides both high optical access and high conductance to vacuum pumps, enabling individual ion addressing and long ion lifetimes, which in turn facilitate more complex quantum simulation experiments. In addition, a multispecies ablation target was developed that incorporates both radioactive barium-133 and metallic barium to enable ion loading at lower trap depths, addressing a common challenge in surface-electrode ion traps. The velocity of the atomic plume generated from barium metal ablation targets was measured and compared to that of BaCl_2 targets. Although we were unable to definitively measure the effective temperature and peak velocity of the atomic plume generated from barium metal, the neutral fluorescence measurements from the barium metal targets indicate a larger number of slower moving atoms compared to BaCl_2 targets. The lower speeds of the atoms generated from metal targets is also plausible due to the low bond energy of metallic bonds compared to covalent bonds in salts. Barium has recently become a popular choice for high-fidelity trapped-ion experiments due to its favorable atomic structure. The larger number of slower moving atoms from barium metal demonstrates that metallic barium could be a much more promising atomic source for barium-based trapped-ion experiments, as the slower plume enables higher loading rates in surface-electrode ion trap systems. Finally, excess micromotion, caused by stray electric fields in RF traps, can lead to undesirable effects such as heating and frequency modulation of atomic transitions. This work evaluates the micromotion compensation capabilities of the Phoenix ion trap used in our system through numerical simulations of single ion trajectories. Through these simulations, it was determined that stray fields of Ex ≈ 3000 V/m, Ey ≈ 3800 V/m, and Ez ≈ 600 V/m can be effectively compensated for with the Phoenix ion trap. With typical stray electric fields in trapped-ion systems ranging from tens to a few hundred V/m, this demonstrates that the Phoenix trap should be well capable of compensating any stray fields expected in our system.

•Sep 22, 2025•0 citations

Towards Integrating a Trapped-Ion Quantum-Bit in a Transmission Electron Microscope

Dominik Hornof, M. Zanetti, Nicolas Jungwirth +4 more

In electron microscopy, the pursuit of atomic-scale resolution for imaging biological [1] samples and soft-matter systems [2] is perpetually constrained by beam-induced sample degredation. While classical approaches attempt to optimize the trade-off between dose efficiency and image quality, they remain fundamentally limited by the physical interactions between electrons and the sample. Quantum technologies, however, present a transformative opportunity by enhancing information extraction per electron without increasing exposure [3], thereby breaking through classical constraints. In this work, we integrate for the first time a trapped-ion qubit into a transmission electron microscope, leveraging the strong Coulomb interaction between swift electrons and Ca⁺ ions [4], along with the precise control and readout capabilities of trapped Ca⁺ ions [5]. By harnessing quantum coherence and controlled interactions, this hybrid approach seeks to advance the capabilities of low-dose imaging, improving the analysis of radiation-sensitive samples while minimizing damage. For this purpose, we customize a transmission electron microscope to provide the required ultra-high-vacuum integrity and adapt the Ca⁺ trap design, including laser cooling and state readout/manipulation, to the geometric constraints of the microscope’s pole-piece gap.

•Apr 20, 2026•0 citations

A low-temperature ultra-high-vacuum scanning probe microscope with in situ electronic transport capabilities: from macro to nano in 10 minutes

Diego Exposito, Oscar Custance, Ivan Brihuega

We have developed a low temperature (LT), ultra-high-vacuum (UHV) system that combines two complementary techniques, scanning probe microscopy (SPM) and electrical transport measurements, within a single platform. By providing simultaneous access to the atomic-scale surface landscape and the macroscopic device response of the same sample, the setup enables direct correlations between local structural/spectroscopic signatures and global electronic transport behavior in two-dimensional (2D) devices. The system allows experiments where atomic-scale modifications or controlled manipulations are performed while continuously monitoring their impact on device-scale performance. The setup consists of two interconnected UHV chambers: a dedicated preparation chamber and a separate measurement chamber that houses a liquid-helium cryostat and the SPM/transport stage. Base pressure is 1x10^-11 Torr. A key feature is direct optical access to the sample, enabling rapid and reliable tip positioning with an accuracy of 5 microns x 5 microns within 10 minutes. The SPM, operated using custom-built electronics, can track the exact same sample region across a temperature range from 2.9 K to 400 K, with mechanical stability below 1 pm. System performance is demonstrated on graphene devices, and bulk Pb is used to determine energy resolution. Using superconducting tips, scanning tunneling spectroscopy measures the superconducting gap with an energy resolution of 30 microV. Transport measurements track the temperature dependence of both resistivity and critical current across the superconducting transition of an in-situ prepared Pb nanowire.

cond-mat.mes-hallCross-listedarXiv:2607.29099•Aug 3, 2026

Free Electron - Trapped Ion Interaction for Quantum Computing Enhanced Electron Microscopy

Elias Pescoller, Santiago Beltrán-Romero, Iva Březinová +2 more

Quantum Computing enhanced Electron Microscopy (QCEM) aims to supplement the classical detector in electron microscopy (EM) with a quantum computer consisting of a trapped-ion lattice. This approach opens the door to a world of novel sensing and imaging techniques. The key ingredient to their development is a thorough understanding of the coupling of free electrons to the vibrational modes of a trapped-ion quantum computer. Here we present initial results, evaluating the scattering matrix elements in different coupling strength regimes, demonstrating the applicability of approximations, and exploring possible use cases of the coupling of a free-electron beam to a quantum computer.

•Nov 5, 2025•0 citations

Coupling free electrons to a trapped-ion quantum computer

Elias Pescoller, Santiago Beltrán-Romero, Sebastian Egginger +10 more

Freely propagating electrons may serve as quantum probes that can become coherently correlated with other quantum systems, offering access to advanced metrological resources. We propose a setup that coherently couples free electrons in an electron microscope to a trapped-ion quantum processor, enabling non-destructive, quantum-coherent detection and the accumulation of information across multiple electrons. Our analysis shows that single electrons can induce resolvable qubit excitations, establishing a platform for practical applications such as quantum-enhanced, dose-efficient electron microscopy.

quant-pharXiv:2601.11446•Physical Review Letters•Jan 19, 2026•4 citations

State-agnostic approach to certifying electron–photon entanglement in electron microscopy

Phila Rembold, Santiago Beltrán-Romero, Alexander Preimesberger +6 more

Transmission electron microscopes (TEMs) enable atomic-scale imaging and characterisation, driving advances across fields from materials science to biology. Quantum correlations, specifically entanglement, may provide a basis for novel hybrid sensing techniques to make TEMs compatible with sensitive samples prone to radiation damage. We present a protocol to certify entanglement between electrons and photons naturally arising from certain coherent cathodoluminescence processes. Using mutually unbiased bases in position and momentum, our method allows robust, state-agnostic entanglement verification and provides a lower bound on the entanglement of formation, enabling quantitative comparisons across platforms. Simulations under experiment-inspired conditions and preliminary experimental data highlight the feasibility of implementing this approach in modern TEM systems with optical specimen access. Our work integrates photonic quantum information techniques with electron microscopy. It establishes a foundation for entanglement-based imaging at the atomic scale, offering a potential pathway to reduce radiation exposure.

arXiv:2502.19536•Quantum Science and Technology•Jul 31, 2025•16 citations
Quantum electron microscopy is an emerging research field at the intersection of electron microscopy, quantum optics, and nanophotonics. Free electrons can serve as powerful quantum probes, on par with photons in their ability to carry and transfer quantum information, generate entanglement within and with a specimen, and reveal previously inaccessible details on nanoscale quantum phenomena [1]. However, quantum experiments are generally highly sensitive to decoherence arising from interactions with residual gas particles, making ultra-high vacuum (UHV) conditions sometimes essential. UHV environments are also required in transmission electron microscopes (TEMs) for the investigation of contamination-sensitive materials [2, 3]. In our project, we aim to combine a trapped-ion quantum computer with a TEM to realise Quantum-Computer-Enhanced Electron Microscopy (QCEM) (www.qcem.info). In this scheme, coherent interactions between free electrons and a trapped ion require vacuum conditions beyond the standard TEM operation [4]. Although UHV-TEM systems have previously been realised [2,3, 5-7], achieving base pressures in the 10⁻⁹ mbar range or better typically involves significant financial investment, long implementation times, and close collaboration with manufacturers. We present a cost-effective, minimally invasive modification to the vacuum system of a JEOL JEM-2100F to reduce the base pressure at the sample position to below 5 × 10⁻⁹ mbar. Our approach is to integrate two additional 50 L/s NEG-ion pumps mounted on flanges near the sample region, with no structural modifications to the microscope. The NEG pumps are integrated into the microscope workflow through controlled activation and regeneration cycles compatible with standard TEM operation. This work represents a practical step toward enabling the realisation of QCEM, and the concept enables a relatively rapid implementation at a moderate cost, which can, in principle, be adapted to any TEM that provides suitable flange access to the sample chamber.
Trapped-ions are one of the leading platforms for quantum information processing, due to their long coherence times and high-fidelity State Preparation and Measurement (SPAM) and gate operations. However, implementing a trapped-ion system with many desirable features such as Ultra-High-Vacuum (UHV), High-Optical-Access (HOA), and a high trapping probability presents significant technical challenges. These features are critical for enabling complex quantum simulation experiments, including simulations of spin-1/2 systems and beyond, by leveraging the multiple internal states of barium and tunable spin–spin interactions. High optical access is required to deliver tightly focused beams for site-resolved control and inter-ion coupling, while UHV conditions are essential for achieving long ion lifetimes necessary for stable, large-scale simulations. Achieving such optical access, which is vital for both coherent gate operations and high numerical aperture fluorescence collection, whilst maintaining vacuum integrity presents substantial engineering challenges. This thesis presents the construction of a vacuum chamber system intended for an individually addressable 16-qubit quantum processor based on barium-133 ions confined in a microfabricated surface-electrode ion trap. Although the complete processor has not yet been realized, the chamber has been assembled to support its future implementation. The microfabricated surface-electrode ion trap features ∼ 100 electrodes that require independent control of static voltages for precise tailoring of the confining electric potential. The experimental setup was designed to provide high optical access and to reach base pressures in the low 10^(−11) mbar range, thereby minimizing ion–background gas collisions. This is achieved by centrally mounting the trap within the vacuum chamber, a departure from conventional flange-mounted designs. To bring in-vacuum electrical connections to ∼ 100 trap electrodes, a custom implementation of an in-vacuum wire harness is described that enables reliable electrical connectivity to the centrally mounted surface electrode ion trap. The development of this wire harness enabled us to reach UHV with a pressure of ≈ 3 × 10^(−11) mbar. The successful development of this wire harness demonstrates that it is possible to create a UHV compatible wiring solution using commercially available components for a surface-electrode ion trap suspended at the center of the vacuum chamber. This centrally mounted design provides both high optical access and high conductance to vacuum pumps, enabling individual ion addressing and long ion lifetimes, which in turn facilitate more complex quantum simulation experiments. In addition, a multispecies ablation target was developed that incorporates both radioactive barium-133 and metallic barium to enable ion loading at lower trap depths, addressing a common challenge in surface-electrode ion traps. The velocity of the atomic plume generated from barium metal ablation targets was measured and compared to that of BaCl_2 targets. Although we were unable to definitively measure the effective temperature and peak velocity of the atomic plume generated from barium metal, the neutral fluorescence measurements from the barium metal targets indicate a larger number of slower moving atoms compared to BaCl_2 targets. The lower speeds of the atoms generated from metal targets is also plausible due to the low bond energy of metallic bonds compared to covalent bonds in salts. Barium has recently become a popular choice for high-fidelity trapped-ion experiments due to its favorable atomic structure. The larger number of slower moving atoms from barium metal demonstrates that metallic barium could be a much more promising atomic source for barium-based trapped-ion experiments, as the slower plume enables higher loading rates in surface-electrode ion trap systems. Finally, excess micromotion, caused by stray electric fields in RF traps, can lead to undesirable effects such as heating and frequency modulation of atomic transitions. This work evaluates the micromotion compensation capabilities of the Phoenix ion trap used in our system through numerical simulations of single ion trajectories. Through these simulations, it was determined that stray fields of Ex ≈ 3000 V/m, Ey ≈ 3800 V/m, and Ez ≈ 600 V/m can be effectively compensated for with the Phoenix ion trap. With typical stray electric fields in trapped-ion systems ranging from tens to a few hundred V/m, this demonstrates that the Phoenix trap should be well capable of compensating any stray fields expected in our system.
In electron microscopy, the pursuit of atomic-scale resolution for imaging biological [1] samples and soft-matter systems [2] is perpetually constrained by beam-induced sample degredation. While classical approaches attempt to optimize the trade-off between dose efficiency and image quality, they remain fundamentally limited by the physical interactions between electrons and the sample. Quantum technologies, however, present a transformative opportunity by enhancing information extraction per electron without increasing exposure [3], thereby breaking through classical constraints. In this work, we integrate for the first time a trapped-ion qubit into a transmission electron microscope, leveraging the strong Coulomb interaction between swift electrons and Ca⁺ ions [4], along with the precise control and readout capabilities of trapped Ca⁺ ions [5]. By harnessing quantum coherence and controlled interactions, this hybrid approach seeks to advance the capabilities of low-dose imaging, improving the analysis of radiation-sensitive samples while minimizing damage. For this purpose, we customize a transmission electron microscope to provide the required ultra-high-vacuum integrity and adapt the Ca⁺ trap design, including laser cooling and state readout/manipulation, to the geometric constraints of the microscope’s pole-piece gap.
We have developed a low temperature (LT), ultra-high-vacuum (UHV) system that combines two complementary techniques, scanning probe microscopy (SPM) and electrical transport measurements, within a single platform. By providing simultaneous access to the atomic-scale surface landscape and the macroscopic device response of the same sample, the setup enables direct correlations between local structural/spectroscopic signatures and global electronic transport behavior in two-dimensional (2D) devices. The system allows experiments where atomic-scale modifications or controlled manipulations are performed while continuously monitoring their impact on device-scale performance. The setup consists of two interconnected UHV chambers: a dedicated preparation chamber and a separate measurement chamber that houses a liquid-helium cryostat and the SPM/transport stage. Base pressure is 1x10^-11 Torr. A key feature is direct optical access to the sample, enabling rapid and reliable tip positioning with an accuracy of 5 microns x 5 microns within 10 minutes. The SPM, operated using custom-built electronics, can track the exact same sample region across a temperature range from 2.9 K to 400 K, with mechanical stability below 1 pm. System performance is demonstrated on graphene devices, and bulk Pb is used to determine energy resolution. Using superconducting tips, scanning tunneling spectroscopy measures the superconducting gap with an energy resolution of 30 microV. Transport measurements track the temperature dependence of both resistivity and critical current across the superconducting transition of an in-situ prepared Pb nanowire.
Quantum Computing enhanced Electron Microscopy (QCEM) aims to supplement the classical detector in electron microscopy (EM) with a quantum computer consisting of a trapped-ion lattice. This approach opens the door to a world of novel sensing and imaging techniques. The key ingredient to their development is a thorough understanding of the coupling of free electrons to the vibrational modes of a trapped-ion quantum computer. Here we present initial results, evaluating the scattering matrix elements in different coupling strength regimes, demonstrating the applicability of approximations, and exploring possible use cases of the coupling of a free-electron beam to a quantum computer.
Freely propagating electrons may serve as quantum probes that can become coherently correlated with other quantum systems, offering access to advanced metrological resources. We propose a setup that coherently couples free electrons in an electron microscope to a trapped-ion quantum processor, enabling non-destructive, quantum-coherent detection and the accumulation of information across multiple electrons. Our analysis shows that single electrons can induce resolvable qubit excitations, establishing a platform for practical applications such as quantum-enhanced, dose-efficient electron microscopy.
Transmission electron microscopes (TEMs) enable atomic-scale imaging and characterisation, driving advances across fields from materials science to biology. Quantum correlations, specifically entanglement, may provide a basis for novel hybrid sensing techniques to make TEMs compatible with sensitive samples prone to radiation damage. We present a protocol to certify entanglement between electrons and photons naturally arising from certain coherent cathodoluminescence processes. Using mutually unbiased bases in position and momentum, our method allows robust, state-agnostic entanglement verification and provides a lower bound on the entanglement of formation, enabling quantitative comparisons across platforms. Simulations under experiment-inspired conditions and preliminary experimental data highlight the feasibility of implementing this approach in modern TEM systems with optical specimen access. Our work integrates photonic quantum information techniques with electron microscopy. It establishes a foundation for entanglement-based imaging at the atomic scale, offering a potential pathway to reduce radiation exposure.