Physical Review A

Systematic errors from inhomogeneous alkali-spin polarization in NMR gyroscopes and comagnetometers

Xiangdong Zhang, Jinbo Hu, Juhao Luo, Chaohong Lee, Nan Zhao

Published May 12, 2026• 1 citation
Publisher

Abstract

Abstract Isotope shift, a systematic error arising from the alkali polarization field generated by the spin-exchange collisions between the Xe and Alkali atoms, has been observed in many $\rm ^{129}Xe$-$\rm ^{131}Xe$ comagnetometer studies. This isotope shift constitutes a major source of systematic errors that ultimately limiting the measurement precision and long-term stability of comagnetometers. In this work, we present a comprehensive analysis of how a spatially inhomogeneous alkali polarization field induces the isotope shift through the diffusion motion of Xe atoms. We identify two primary physical mechanisms responsible for the isotope shift: the mismatch of the wall relaxation rates and the large difference of the gyromagnetic ratios between $\rm ^{129}Xe$ and $\rm ^{131}Xe$ spins. Focusing on the alkali polarization field produced by a Gaussian pump beam, we perform detailed analytical and numerical evaluations on the magnitude and stability of isotope shift. These results offer practical guidance for optimizing the experimental working point, thereby enhancing the absolute accuracy and long-term stability of $\rm ^{129}Xe$-$\rm ^{131}Xe$ comagnetometers and nuclear magnetic resonance (NMR) gyroscopes.

DOI
10.1103/tf57-n616

Related papers

The Isotope Shift Suppression in NMR-based Balanced Quantum Rotation Sensor

V. I. Petrov, Anton K. Vershovskii

Abstract— Designing a compact balanced quantum rotation sensor (gyroscope) based on nuclear magnetic resonance in xenon is one of the most urgent and promising tasks in modern metrology. The ultimate accuracy of the sensor is mostly constrained by the isotope shift conditioned by the difference in relaxation rates of two xenon isotopes under spatially nonuniform spin-exchange pumping of nuclear magnetic moments. The proposed method for suppressing the isotope shift and its partial derivatives is based on creating the external magnetic field with nonlinear spatial gradient. The simulation results based on experimental data demonstrate that the method can be applied to small gas cells with higher spatial nonlinearity of pumping parameters.

Gyroscopy and Navigation•Jun 1, 2022•3 citations

Continuous comagnetometry using transversely polarized Xe isotopes

Daniel Thrasher, Susan Sorensen, J. Weber +4 more

We demonstrate a transversely polarized spin-exchange pumped noble gas comagnetometer which suppresses systematic errors from longitudinal polarization. Rb atoms as well as $^{131}\mathrm{Xe}$ and $^{129}\mathrm{Xe}$ nuclei are simultaneously polarized perpendicular to a pulsed bias field. Both Xe isotopes' nuclear magnetic resonance conditions are simultaneously satisfied by frequency modulation of the pulse repetition rate. The Rb atoms detect the Xe precession. We highlight the importance of magnetometer phase shifts when performing comagnetometry. For detection of nonmagnetic spin-dependent interactions the sensing bandwidth is 1 Hz, the white-noise level is $7\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{Hz}/\sqrt{\text{Hz}}$, and the bias instability is $\ensuremath{\sim}1$ $\ensuremath{\mu}\mathrm{Hz}$.

arXiv:1910.02156•Physical Review A•Dec 9, 2019•42 citations

Impact of heavy noble gases on the magnetic resonance linewidth of alkali-metal atoms

Feng Tang, Kaiming Yan, Nan Zhao

Abstract Nuclear magnetic resonance gyroscopes (NMRGs) employ noble-gas nuclear spins as inertial sensors and alkali-metal atoms as in-situ magnetometers. Heavy noble gases, particularly xenon, are widely used due to their long nuclear spin relaxation time and strong spin-exchange coupling with alkali-metal atoms. However, their presence introduces additional collisional mechanisms that affect the alkali-metal magnetic resonance linewidth, thereby influencing magnetometer sensitivity and overall gyro performance. In this work, we employ a theoretical framework based on the density matrix formalism and master equation approach to quantitatively study how xenon-induced two-body and three-body interactions modify the linewidth of alkali-metal atoms under realistic NMRG conditions. Our analysis reveals that Xe atoms primarily broaden the linewidth via binary spin-destruction collisions and van der Waals (vdW)-mediated F-damping processes, while the effect of Xe nuclear polarization is negligible at the ∼ 1 % level. We further demonstrate that nitrogen buffer gas plays a dual role: it directly contributes to alkali-metal spin relaxation through binary collisions and indirectly modulates vdW collision rates by altering molecular lifetimes. The interplay between these processes leads to an optimal nitrogen density that minimizes the linewidth. Additionally, we identify a temperature threshold above which light-narrowing emerges, with this threshold increasing alongside Xe density. These findings provide theoretical insight for optimizing spin relaxation control in alkali-metal magnetometers and improving NMRG performance.

arXiv:2506.19249•Journal of Physics B Atomic Molecular and Optical Physics•Jun 5, 2026•0 citations

Improvement of polarization uniformity in spin-exchange relaxation-free comagnetometer based on pump beam reflection compensation

JiaLu Meng, Feng Liu, Xihui Dou +2 more

Spin exchange relaxation free (SERF) comagnetometers, which use coupled alkali metal and noble gas spins, are promising for precision measurements due to their potential for miniaturization and high sensitivity. In these systems, alkali atoms are optically pumped with circularly polarized light, and their polarization is transferred to noble gas nuclei via spin-exchange collisions. However, spatial inhomogeneities in alkali polarization induced by factors such as optical absorption, gas diffusion, and temperature gradients generate effective magnetic field gradients for the noble gas spins. These gradients accelerate spin relaxation and degrade overall sensor performance. This work introduces a pump beam reflection compensation scheme to improve alkali polarization uniformity in a SERF comagnetometer. By retro reflecting the pump beam back along its original optical path with reversed helicity, alkali atoms are repolarized from the opposite direction. This counter propagating beam compensates polarization gradients through reverse optical pumping, thereby homogenizing the effective field experienced by the noble gas spins. The modified pumping configuration enhances spatial uniformity while maintaining a simple and compact sensor architecture. A revised polarization rate model incorporating the retro reflected beam is presented. Simulations comparing single beam, 90% reflection, and total reflection configurations confirm a marked reduction in alkali polarization gradients for reflection based designs. Experimentally, the transverse relaxation time of the noble gas spins is extended by 77.66%, indicating significantly suppressed gradient induced decoherence. The proposed method supports the development of miniaturized, high performance SERF comagnetometers.

Sixth Symposium on Novel Optoelectronic Detection Technology and Applications•May 11, 2026•0 citations

Examination of Spin-Exchange Relaxation in the Alkali Metal-Noble Gas Comagnetometer With a Large Electron Magnetic Field

Liwei Jiang, Lihong Duan, Jiali Liu +3 more

Alkali metal-noble gas comagnetometers operated in the regime of spin-exchange relaxation-free (SERF) have been widely used in fundamental physics tests and rotation sensing as gyroscope. Spin-exchange relaxation is an important systematic bias of the comagnetometer, which could limit sensitivity significantly. However, the suppression effect of the spin-exchange relaxation has not been examined quantitatively so far. Herein, we systematically investigate the relaxation of the alkali metal atoms and find that the spin-exchange relaxation is not completely eliminated under the normal operating condition of the K-Rb-21Ne comagnetometer. In addition to the optical pumping rate, the spin-exchange relaxation still plays a dominant role in the broadening of electron Zeeman resonances due to the large electron magnetic field. This is the first demonstration that the alkali metal atoms are operated in the near-SERF regime in the alkali metal-noble gas comagnetometer with a large election magnetic field, which will shed light on the way to reduce the relaxation of the alkali metal atoms and enhance the sensitivity of the comagnetometer.

IEEE Transactions on Instrumentation and Measurement•Oct 26, 2020•18 citations

Optimization of Nuclear Polarization in an Alkali-Noble Gas Comagnetometer

Emmanuel Klinger, Tianhao Liu, Mikhail Padniuk +6 more

Self-compensated comagnetometers, employing overlapping samples of spin-polarized alkali and noble gases (for example K-${}^{3}\mathrm{He}$) are promising sensors for exotic beyond-the-standard-model fields and high-precision metrology such as rotation sensing. When the comagnetometer operates in the so-called self-compensated regime, the effective field, originating from contact interactions between the alkali valence electrons and the noble-gas nuclei, is compensated with an applied magnetic field. When the comagnetometer begins operation in a given magnetic field, spin-exchange optical pumping establishes an equilibrium between the alkali electron-spin polarization and the nuclear-spin polarization. Subsequently, when the magnetic field is tuned to the compensation point, the spin polarization is brought out of the equilibrium conditions. This causes a practical issue for long measurement times. We report on a method for closed-loop control of the compensation field. This method allows optimization of the operating parameters, especially magnetic field gradients, in spite of the inherently slow (hours to days) dynamics of the system. With the optimization, higher stable nuclear polarization, longer relaxation times, and stronger electron-nuclear coupling are achieved which is useful for nuclear-spin-based quantum memory, spin amplifiers, and gyroscopes. The optimized sensor demonstrates a sensitivity comparable to the best previous comagnetometer but with four times lower noble-gas density. This paves the way for applications in both fundamental and applied science.

arXiv:2210.07687•Physical Review Applied•Apr 28, 2023•37 citations
Abstract Isotope shift, a systematic error arising from the alkali polarization field generated by the spin-exchange collisions between the Xe and Alkali atoms, has been observed in many 129Xe\rm ^{129}Xe129Xe-131Xe\rm ^{131}Xe131Xe comagnetometer studies. This isotope shift constitutes a major source of systematic errors that ultimately limiting the measurement precision and long-term stability of comagnetometers. In this work, we present a comprehensive analysis of how a spatially inhomogeneous alkali polarization field induces the isotope shift through the diffusion motion of Xe atoms. We identify two primary physical mechanisms responsible for the isotope shift: the mismatch of the wall relaxation rates and the large difference of the gyromagnetic ratios between 129Xe\rm ^{129}Xe129Xe and 131Xe\rm ^{131}Xe131Xe spins. Focusing on the alkali polarization field produced by a Gaussian pump beam, we perform detailed analytical and numerical evaluations on the magnitude and stability of isotope shift. These results offer practical guidance for optimizing the experimental working point, thereby enhancing the absolute accuracy and long-term stability of 129Xe\rm ^{129}Xe129Xe-131Xe\rm ^{131}Xe131Xe comagnetometers and nuclear magnetic resonance (NMR) gyroscopes.
Abstract— Designing a compact balanced quantum rotation sensor (gyroscope) based on nuclear magnetic resonance in xenon is one of the most urgent and promising tasks in modern metrology. The ultimate accuracy of the sensor is mostly constrained by the isotope shift conditioned by the difference in relaxation rates of two xenon isotopes under spatially nonuniform spin-exchange pumping of nuclear magnetic moments. The proposed method for suppressing the isotope shift and its partial derivatives is based on creating the external magnetic field with nonlinear spatial gradient. The simulation results based on experimental data demonstrate that the method can be applied to small gas cells with higher spatial nonlinearity of pumping parameters.
We demonstrate a transversely polarized spin-exchange pumped noble gas comagnetometer which suppresses systematic errors from longitudinal polarization. Rb atoms as well as 131Xe^{131}\mathrm{Xe}131Xe and 129Xe^{129}\mathrm{Xe}129Xe nuclei are simultaneously polarized perpendicular to a pulsed bias field. Both Xe isotopes' nuclear magnetic resonance conditions are simultaneously satisfied by frequency modulation of the pulse repetition rate. The Rb atoms detect the Xe precession. We highlight the importance of magnetometer phase shifts when performing comagnetometry. For detection of nonmagnetic spin-dependent interactions the sensing bandwidth is 1 Hz, the white-noise level is $7\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{Hz}/\sqrt{\text{Hz}}$, and the bias instability is $\ensuremath{\sim}1$ $\ensuremath{\mu}\mathrm{Hz}$.
Abstract Nuclear magnetic resonance gyroscopes (NMRGs) employ noble-gas nuclear spins as inertial sensors and alkali-metal atoms as in-situ magnetometers. Heavy noble gases, particularly xenon, are widely used due to their long nuclear spin relaxation time and strong spin-exchange coupling with alkali-metal atoms. However, their presence introduces additional collisional mechanisms that affect the alkali-metal magnetic resonance linewidth, thereby influencing magnetometer sensitivity and overall gyro performance. In this work, we employ a theoretical framework based on the density matrix formalism and master equation approach to quantitatively study how xenon-induced two-body and three-body interactions modify the linewidth of alkali-metal atoms under realistic NMRG conditions. Our analysis reveals that Xe atoms primarily broaden the linewidth via binary spin-destruction collisions and van der Waals (vdW)-mediated F-damping processes, while the effect of Xe nuclear polarization is negligible at the ∼ 1 % level. We further demonstrate that nitrogen buffer gas plays a dual role: it directly contributes to alkali-metal spin relaxation through binary collisions and indirectly modulates vdW collision rates by altering molecular lifetimes. The interplay between these processes leads to an optimal nitrogen density that minimizes the linewidth. Additionally, we identify a temperature threshold above which light-narrowing emerges, with this threshold increasing alongside Xe density. These findings provide theoretical insight for optimizing spin relaxation control in alkali-metal magnetometers and improving NMRG performance.
Spin exchange relaxation free (SERF) comagnetometers, which use coupled alkali metal and noble gas spins, are promising for precision measurements due to their potential for miniaturization and high sensitivity. In these systems, alkali atoms are optically pumped with circularly polarized light, and their polarization is transferred to noble gas nuclei via spin-exchange collisions. However, spatial inhomogeneities in alkali polarization induced by factors such as optical absorption, gas diffusion, and temperature gradients generate effective magnetic field gradients for the noble gas spins. These gradients accelerate spin relaxation and degrade overall sensor performance. This work introduces a pump beam reflection compensation scheme to improve alkali polarization uniformity in a SERF comagnetometer. By retro reflecting the pump beam back along its original optical path with reversed helicity, alkali atoms are repolarized from the opposite direction. This counter propagating beam compensates polarization gradients through reverse optical pumping, thereby homogenizing the effective field experienced by the noble gas spins. The modified pumping configuration enhances spatial uniformity while maintaining a simple and compact sensor architecture. A revised polarization rate model incorporating the retro reflected beam is presented. Simulations comparing single beam, 90% reflection, and total reflection configurations confirm a marked reduction in alkali polarization gradients for reflection based designs. Experimentally, the transverse relaxation time of the noble gas spins is extended by 77.66%, indicating significantly suppressed gradient induced decoherence. The proposed method supports the development of miniaturized, high performance SERF comagnetometers.
Alkali metal-noble gas comagnetometers operated in the regime of spin-exchange relaxation-free (SERF) have been widely used in fundamental physics tests and rotation sensing as gyroscope. Spin-exchange relaxation is an important systematic bias of the comagnetometer, which could limit sensitivity significantly. However, the suppression effect of the spin-exchange relaxation has not been examined quantitatively so far. Herein, we systematically investigate the relaxation of the alkali metal atoms and find that the spin-exchange relaxation is not completely eliminated under the normal operating condition of the K-Rb-21Ne comagnetometer. In addition to the optical pumping rate, the spin-exchange relaxation still plays a dominant role in the broadening of electron Zeeman resonances due to the large electron magnetic field. This is the first demonstration that the alkali metal atoms are operated in the near-SERF regime in the alkali metal-noble gas comagnetometer with a large election magnetic field, which will shed light on the way to reduce the relaxation of the alkali metal atoms and enhance the sensitivity of the comagnetometer.
Self-compensated comagnetometers, employing overlapping samples of spin-polarized alkali and noble gases (for example K-3He{}^{3}\mathrm{He}3He) are promising sensors for exotic beyond-the-standard-model fields and high-precision metrology such as rotation sensing. When the comagnetometer operates in the so-called self-compensated regime, the effective field, originating from contact interactions between the alkali valence electrons and the noble-gas nuclei, is compensated with an applied magnetic field. When the comagnetometer begins operation in a given magnetic field, spin-exchange optical pumping establishes an equilibrium between the alkali electron-spin polarization and the nuclear-spin polarization. Subsequently, when the magnetic field is tuned to the compensation point, the spin polarization is brought out of the equilibrium conditions. This causes a practical issue for long measurement times. We report on a method for closed-loop control of the compensation field. This method allows optimization of the operating parameters, especially magnetic field gradients, in spite of the inherently slow (hours to days) dynamics of the system. With the optimization, higher stable nuclear polarization, longer relaxation times, and stronger electron-nuclear coupling are achieved which is useful for nuclear-spin-based quantum memory, spin amplifiers, and gyroscopes. The optimized sensor demonstrates a sensitivity comparable to the best previous comagnetometer but with four times lower noble-gas density. This paves the way for applications in both fundamental and applied science.