单粒子的制备、操控与探测是实验物理技术发展的重点方向之一。其中确定性单离子的制备和纳米级定位作为新一代离子束技术的核心目标,可为量子科技与原子级制造等前沿科技领域的发展提供关键技术支撑。本文报道了一种基于时间关联测量的确定性单离子源技术。利用磁光阱中冷原子光电离产生的电子-离子对的时间关联性,通过符合测量技术,将电子作为触发信号调控离子运动轨迹,实现高保真度单离子源的确定性制备。我们分别在连续流模式和单离子模式下对离子源性能进行了表征:在连续流模式下,电子和离子计数率分别为4.9×103 s-1和4.9×104 s-1;在单离子模式下,电子-离子符合率最大值为53.5%,单离子保真度为80.1%。单离子的聚焦成像结果和基于实验参数的数值模拟结果表明,确定性单离子源的发射度为(1.01 ± 0.06)×10-10 m rad eV1/2,亮度为(7.2 ± 0.8)×102 A m-2 Sr-1 eV-1,满足确定性单离子纳米束技术开发的需求。本方案在离子种类与单离子操控等方面具备良好的可扩展性,在离子显微成像和高精度单离子注入等前沿领域方面展现出广阔的应用前景。
单粒子的制备、操控与探测是实验物理技术发展的重点方向之一。其中确定性单离子的制备和纳米级定位作为新一代离子束技术的核心目标,可为量子科技与原子级制造等前沿科技领域的发展提供关键技术支撑。本文报道了一种基于时间关联测量的确定性单离子源技术。利用磁光阱中冷原子光电离产生的电子-离子对的时间关联性,通过符合测量技术,将电子作为触发信号调控离子运动轨迹,实现高保真度单离子源的确定性制备。我们分别在连续流模式和单离子模式下对离子源性能进行了表征:在连续流模式下,电子和离子计数率分别为4.9×103 s-1和4.9×104 s-1;在单离子模式下,电子-离子符合率最大值为53.5%,单离子保真度为80.1%。单离子的聚焦成像结果和基于实验参数的数值模拟结果表明,确定性单离子源的发射度为(1.01 ± 0.06)×10-10 m rad eV1/2,亮度为(7.2 ± 0.8)×102 A m-2 Sr-1 eV-1,满足确定性单离子纳米束技术开发的需求。本方案在离子种类与单离子操控等方面具备良好的可扩展性,在离子显微成像和高精度单离子注入等前沿领域方面展现出广阔的应用前景。
We report on a measurement of the characteristic temperature of an ultracold rubidium ion source, in which a cloud of laser-cooled atoms is converted to ions by photo-ionization. Extracted ion pulses are focused on a detector with a pulsed-field technique. The resulting experimental spot sizes are compared to particle-tracking simulations, from which an effective source temperature T = (3 ± 2) mK and the corresponding transversal reduced emittance εr = 1.4 × 10−8 m rad eV are determined. Space charge effects that may affect the measurement are also discussed.
At present, the smallest spot size which can be achieved with state-of-the-art focused ion beam (FIB) technology is mainly limited by the chromatic aberrations associated with the 4.5 eV energy spread of the liquid-metal ion source. Here we numerically investigate the performance of an ultracold ion source which has the potential for generating ion beams which combine high brightness with small energy spread. The source is based on creating very cold ion beams by near-threshold photoionization of a laser-cooled and trapped atomic gas. We present ab initio numerical calculations of the generation of ultracold beams in a realistic acceleration field and including all Coulomb interactions, i.e., both space charge effects and statistical Coulomb effects. These simulations demonstrate that with existing technology reduced brightness values exceeding 105 A m−2 sr−1 V−1 are feasible at an energy spread as low as 0.1 eV. The estimated spot size of the ultracold ion source in a FIB instrument ranges from 10 nm at a current of 100 pA to 0.8 nm at 1 pA.
UltraCold Ion Beam Source. Focused ion beam (FIB) machines are largely used in the semiconductor industry mainly for imaging, milling and deposition of material, at the nanometer scale. To keep up with the trend of making smaller and smaller components, FIBs need to be continuously improved. A FIB is mainly made of an ion source and a focusing column. In this thesis, two concepts of ion sources are presented, modeled and discussed. The ultra-cold ion source (UCIS) is based on creating very cold ion beams (T <1 mK) by near-threshold photo-ionization of a laser-cooled and trapped atomic gas. In our experiment, 85Rb atoms are confined in a magneto optical trap built directly inside an accelerator structure. A spherical portion of the atom cloud is ionized with a 2-step ionization process and the bunched ions are accelerated by either a DC or a pulsed electric field. The liquid-metal ion source (LMIS) is the current state-of-art for focused ion beam technology, having a reduced brightness of 106 A/m2 sr eV. The reduced brightness characterizes the source and is proportional to the ion current and inversely proportional to the beam emittance (closely related with the source temperature). A high brightness is of importance as much as a low energy spread of the ion beam, since the latter is related with the focus ability of the beam. We have already shown that the UCIS can provide much lower energy spread (20 meV) than LMIS (˜ 4.5 eV), see Reijnders et al. (PRL, 2009), but not yet in combination with a high brightness as well. The energy spread is the limiting factor for the final achievable spot size in a FIB based on a LMIS. Chapter 3 and 4 present measurements of the source temperature and of the extracted current to complete the characterization of the UCIS. The ultra low temperature of the source permits collimated bunches to be created at low kinetic energy (down to few eV), which allows using time-dependent fields for accelerating and focusing. With this lens, a transversal ion temperature of (3±2) mK has been measured, as shown in chapter 3. This temperature is an upper limit since it is ten times higher than the expected value. The novel technique of focusing with time-dependent electric field is successfully applied to an ultra cold ion beam. In chapter 4, a dynamic model of the source describing its properties under pulsed operation has been developed and experiments validated it. A maximum average ion current of (13 ± 1) pA has been extracted from the UCIS and this is enough for imaging (1-100 pA are used). Those results correspond to a source reduced brightness of (8 ± 1) × 104 A/m2 sr eV with 0.9 eV energy spread. This result is 12.5 times lower than the brightness of a LMIS. An interesting "pushing effect", due to the laser used to excite the atoms in the cloud, is described as well. Particle tracking simulations show that disorder induced heating has an important effect on the brightness, lowering its value by 1-2 orders of magnitude depending on the extracted current. Calculations and simulations of a different ion source, the atomic beam laser-cooled ion source (ABLIS), are presented in chapter 6. The follow-up project is based on a similar idea as an UCIS but aims for production of ion beams from a much higher initial atomic flux. The atoms originate from a Knudsen cell and, after being cooled and compressed transversally with laser cooling and trapping techniques, are photo-ionized and accelerated. The source size is reduced as well with respect to the UCIS. Realistic particle tracking simulations with 87Rb show that disorder induced heating is still very important, but in certain conditions, the so-called "pencil-beam" regime is reached and the disorder-induced heating does not deteriorate the brightness anymore. Depending on the extracted current, it is possible to reach a reduced brightness of 2 × 107 A/m2 sr eV with an ion current of 22 pA (corresponding to a final aperture diameter df = 1.6 µm) and an energy spread of 0.7 eV can be achieved. This source is likely capable of provide a high brightness and a low energy spread at the same time. The calculations are done assuming a purified 87Rb source. Eventually, it is possible to reach very high current (1 nA), making the ABLIS ideal also for milling applications with FIBs.