Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

First optical frequency ratio measurement with the forbidden 1S0-3P0 clock transition in bosonic 198Hg

T. Lauprêtre, Clara Zyskind, Ashley Beguin, Benjamin Pointard, Rodolphe Le Targat, Jérôme Lodewyck, S. Bize

Published Apr 20, 2026• 0 citations
OpenAlex

Related papers

First observation of the bosonic 198Hg clock transition in an optical lattice clock

Clara Zyskind, S. Bize, Jérôme Lodewyck +3 more

•Jun 25, 2024•0 citations

Experimental set-up for study of collisions of cold mercury atoms for optical frequency clocks

Marcin Witkowski, Sławomir Bilicki, Bartłomiej Nagórny +5 more

We present an experimental set-up of two species mercury-rubidium magneto-optical trap (MOT). The preliminary studies of interactions in mercury MOT and mercury-rubidium MOT are presented. In bosons with the s2 configuration the clock transition 1S0-3P0 is strictly forbidden. The commonly used method to overcome this problem is to induce a coupling with 3P0 state with a state which is optically accessible. In the mercury-rubidium MOT, the presence of cold Rb atoms might be used to tune the probability of the 1S0-3P0 clock transition in mercury.

European Frequency and Time Forum•Jun 1, 2014•0 citations

Observation of the 1S0–3P0 optical clock transition in cold 199Hg atoms

Xiaohu Fu, Su Fang, Ru-Chen Zhao +5 more

We report on the observation of the highly forbidden 1S0–3P0 optical clock transition in laser-cooled 199Hg atoms. More than 95% depletion of cold 199Hg atoms is detected in the magneto-optical trap. Using the free-of-field detection method, the AC Stark shift from the cooling laser is removed from the in-field spectroscopy. At low-power clock laser pumping, the linewidth of the clock spectroscopy is approximately 450 kHz (full width at half-maximum), which corresponds to a Doppler broadening at the atom temperature of 60 μK. We determine the 1S0–3P0 transition frequency to be 1,128,575,290.819(14) MHz by referencing with a hydrogen maser and measuring with a fiber optical frequency comb. Moreover, a weak Doppler-free signal is observed.

Chinese Optics Letters•Jan 1, 2018•5 citations

Optical frequency standards based on trapped neutral atoms

S. Bize

•Feb 7, 2013•0 citations

Evaluation of an In+ Coulomb crystal clock with relative uncertainties in the low 10−18 range

H. N. Hausser

Clocks have been among the most accurate man-made devices for centuries. Atomic clocks, which have been defining time by means of a microwave transition in the 133Cs atom since 1967, represent a major step in this development. A redefinition of the SI unit of time based on optical atomic clocks is currently under discussion. This forthcoming redefinition requires, among other criteria, the repeated demonstration of the consistency of different optical frequency standards in the low 10−18 range. In this work, the first evaluation of the systematic shifts and their uncertainties in a 115In+–172Yb+ Coulomb crystal clock is presented. This clock utilizes the 1S0 ↔ 3P0 transition in 115In+. 172Yb+ ions are co-trapped with the 115In+ ions in a segmented Paul trap and used for sympathetic cooling. With a systematic uncertainty of 2.5×10−18 when operating with a 1In+–3Yb+ crystal and 2.6×10−18 when operating with a 2In+–4Yb+ crystal, this clock is one of the most accurate clocks in the world. In addition, the operation of the clock with multiple clock ions is the first of its kind at this level of uncertainty. Measurements with up to four clock ions show a reduction in instability from 1.6×10−15/√ τ for a single indium ion to 9.2(4)×10−16/√τ when operating with four indium ions. By using an additional quench laser, the instability in another series of measurements was reduced from a single-ion instability of 1.5×10−15/√ τ to a four-ion instability of 7.1(15)×10−16/√τ , which is consistent with the expected scaling of 1/√N with the number of clock ions N. In this work, the hyperfine structure of the 3P0 ↔ 1P1 transition used for quenching was also resolved for the first time and the hyperfine constants were determined to be AHFS = 265.42(75)MHz and BHFS = 291.4(135) MHz. In frequency comparisons with other clocks, the optical frequency ratios 115In+/171Yb+(E3) and 115In+/87Sr were determined. With a relative total uncertainty of 4.2 × 10−18, the former ratio is the most accurate frequency ratio of different species published to date. It is also the first to meet one of the requirements defined on the roadmap for redefining the SI unit of the second: Measurements of frequency ratios with relative total measurement uncertainties below 5 × 10−18. The determination of the absolute frequency results in an uncertainty of 1.3 × 10−16 for the 1S0 ↔ 3P0 transition in 115In+, which is limited by that of the cesium fountains. The results obtained summarized: ν115In+ ν171Yb+(E3) =1.973 773 591 557 215 788(8) ν115In+ ν87Sr =2.952 748 749 874 860 781(27) ν115In+ =1 267 402 452 901 038.87(16) Hz

•Jan 1, 2025•0 citations

Spectroscopy of a solid-state optical clock transition

Mohit Verma, Hiromitsu Sawaoka, Amar C. Vutha

Bulletin of the American Physical Society•May 29, 2018•0 citations
We present an experimental set-up of two species mercury-rubidium magneto-optical trap (MOT). The preliminary studies of interactions in mercury MOT and mercury-rubidium MOT are presented. In bosons with the s2 configuration the clock transition 1S0-3P0 is strictly forbidden. The commonly used method to overcome this problem is to induce a coupling with 3P0 state with a state which is optically accessible. In the mercury-rubidium MOT, the presence of cold Rb atoms might be used to tune the probability of the 1S0-3P0 clock transition in mercury.
We report on the observation of the highly forbidden 1S0–3P0 optical clock transition in laser-cooled 199Hg atoms. More than 95% depletion of cold 199Hg atoms is detected in the magneto-optical trap. Using the free-of-field detection method, the AC Stark shift from the cooling laser is removed from the in-field spectroscopy. At low-power clock laser pumping, the linewidth of the clock spectroscopy is approximately 450 kHz (full width at half-maximum), which corresponds to a Doppler broadening at the atom temperature of 60 μK. We determine the 1S0–3P0 transition frequency to be 1,128,575,290.819(14) MHz by referencing with a hydrogen maser and measuring with a fiber optical frequency comb. Moreover, a weak Doppler-free signal is observed.
Clocks have been among the most accurate man-made devices for centuries. Atomic clocks, which have been defining time by means of a microwave transition in the 133Cs atom since 1967, represent a major step in this development. A redefinition of the SI unit of time based on optical atomic clocks is currently under discussion. This forthcoming redefinition requires, among other criteria, the repeated demonstration of the consistency of different optical frequency standards in the low 10−18 range. In this work, the first evaluation of the systematic shifts and their uncertainties in a 115In+–172Yb+ Coulomb crystal clock is presented. This clock utilizes the 1S0 ↔ 3P0 transition in 115In+. 172Yb+ ions are co-trapped with the 115In+ ions in a segmented Paul trap and used for sympathetic cooling. With a systematic uncertainty of 2.5×10−18 when operating with a 1In+–3Yb+ crystal and 2.6×10−18 when operating with a 2In+–4Yb+ crystal, this clock is one of the most accurate clocks in the world. In addition, the operation of the clock with multiple clock ions is the first of its kind at this level of uncertainty. Measurements with up to four clock ions show a reduction in instability from 1.6×10−15/√ τ for a single indium ion to 9.2(4)×10−16/√τ when operating with four indium ions. By using an additional quench laser, the instability in another series of measurements was reduced from a single-ion instability of 1.5×10−15/√ τ to a four-ion instability of 7.1(15)×10−16/√τ , which is consistent with the expected scaling of 1/√N with the number of clock ions N. In this work, the hyperfine structure of the 3P0 ↔ 1P1 transition used for quenching was also resolved for the first time and the hyperfine constants were determined to be AHFS = 265.42(75)MHz and BHFS = 291.4(135) MHz. In frequency comparisons with other clocks, the optical frequency ratios 115In+/171Yb+(E3) and 115In+/87Sr were determined. With a relative total uncertainty of 4.2 × 10−18, the former ratio is the most accurate frequency ratio of different species published to date. It is also the first to meet one of the requirements defined on the roadmap for redefining the SI unit of the second: Measurements of frequency ratios with relative total measurement uncertainties below 5 × 10−18. The determination of the absolute frequency results in an uncertainty of 1.3 × 10−16 for the 1S0 ↔ 3P0 transition in 115In+, which is limited by that of the cesium fountains. The results obtained summarized: ν115In+ ν171Yb+(E3) =1.973 773 591 557 215 788(8) ν115In+ ν87Sr =2.952 748 749 874 860 781(27) ν115In+ =1 267 402 452 901 038.87(16) Hz