Positron emission tomography (PET) with long axial field-of-view (LAFOV) scanners generates unprecedentedly large datasets, posing major challenges for conventional reconstruction algorithms. Recent advances in deep learning have improved PET image quality, yet scaling to high-dimensional data remains computationally demanding. Quantum computing (QC) offers new opportunities to address such challenges. This work presents a pilot study on image denoising using a hybrid quantum-classical autoencoder. The model employs a classical encoder, a quantum bottleneck implemented via a parameterized quantum circuit, and a classical decoder. Using simulated experiments on the medical modified national institute of standards and technology (MedMNIST) dataset with 28 × 28 grayscale images and on PET scan images with 64 × 64, results demonstrated that the quantum bottleneck can effectively recover structural details from noisy inputs. While scaling to large-volume PET data will require advances in quantum hardware, circuit design, and error mitigation, these results highlight the potential of hybrid quantum–classical approaches to complement deep learning in PET reconstruction.
Positron emission tomography (PET) with long axial field-of-view (LAFOV) scanners generates unprecedentedly large datasets, posing major challenges for conventional reconstruction algorithms. Recent advances in deep learning have improved PET image quality, yet scaling to high-dimensional data remains computationally demanding. Quantum computing (QC) offers new opportunities to address such challenges. This work presents a pilot study on image denoising using a hybrid quantum-classical autoencoder. The model employs a classical encoder, a quantum bottleneck implemented via a parameterized quantum circuit, and a classical decoder. Using simulated experiments on the medical modified national institute of standards and technology (MedMNIST) dataset with 28 × 28 grayscale images and on PET scan images with 64 × 64, results demonstrated that the quantum bottleneck can effectively recover structural details from noisy inputs. While scaling to large-volume PET data will require advances in quantum hardware, circuit design, and error mitigation, these results highlight the potential of hybrid quantum–classical approaches to complement deep learning in PET reconstruction.
Deep learning has transformed radiology, but the computational cost of training and deploying modern models is outpacing what classical hardware can support. Quantum computing has been proposed as one response to this bottleneck: an n-qubit system can represent 2n states simultaneously, although practical speedups require efficient algorithms, data encoding, and measurement strategies rather than superposition alone. This review introduces radiologists to five core quantum concepts, qubits, superposition, entanglement, quantum gates, and quantum circuits, and to the superconducting, trapped-ion, and photonic hardware platforms that define the current noisy intermediate-scale quantum (NISQ) era. We then summarize the quantum machine learning architectures most often applied to medical imaging (quantum support vector machines, quantum neural networks, variational quantum circuits, and quantum convolutional neural networks) and quantum image representations such as the flexible representation of quantum images (FRQI) and the novel enhanced quantum representation (NEQR). Reported applications include brain tumor classification and segmentation on MRI, pneumonia detection on chest radiographs, skin and breast lesion classification, CT and PET reconstruction, and ultrasound denoising. Nearly all published systems are hybrid quantum-classical pipelines evaluated on small, downsampled benchmark datasets or simulators, and clinical deployment is not yet feasible. We conclude with current limitations and translational priorities for radiology.
Multi-modal biomedical imaging has become central to modern diagnostics, offering complementary anatomical, functional, and molecular information through modalities such as MRI, CT, PET, ultrasound, and optical imaging. Yet integrating these heterogeneous datasets remains computationally demanding due to differences in spatial resolution, noise profiles, acquisition dynamics, and high-dimensional feature distributions. This paper investigates AI–quantum hybrid diagnostic systems as an emerging paradigm for multimodal image fusion, reconstruction, and disease classification. By combining deep learning architectures with quantum-enhanced algorithms—including variational quantum circuits, quantum feature encoders, and quantum kernel methods—the hybrid framework aims to accelerate image processing, improve cross-modal consistency, and enhance diagnostic precision. The analysis highlights advancements in quantum-accelerated denoising, multi-modal registration, probabilistic inference, and high-dimensional pattern recognition. It also evaluates workflow integration challenges, such as NISQ-era noise, hardware scalability, and clinical interpretability. Overall, AI–quantum hybrid systems represent a promising frontier in medical imaging, offering potential improvements in speed, sensitivity, and personalized diagnostic accuracy.
Building a 3D scene from a limited number of images remains a challenging problem in computer vision, particularly for applications such as augmented reality, robotics, medical imaging, and autonomous navigation. Existing deep learning models like LRM and vFusion3D achieve high-quality reconstructions but require significant computational resources and long inference times, making them difficult to deploy on edge devices. This research introduces QuantumVision, a hybrid quantum-classical framework that integrates quantum image-processing techniques into a traditional 3D reconstruction pipeline. The framework consists of three modular components: quantum-assisted preprocessing, amplitude-based feature encoding, and a variational quantum optimization stage. These modules are designed to integrate with classical workflows while leveraging the potential advantages of Noisy Intermediate-Scale Quantum (NISQ) devices. Experimental simulations using Qiskit demonstrate improved feature extraction, edge detection, and reconstruction fidelity compared to classical baselines. The proposed approach highlights the potential of hybrid quantum computing to enhance computational efficiency and accuracy in partial-view 3D reconstruction tasks while remaining compatible with current quantum hardware limitations.
This thesis investigates inverse problems in emission tomography from three complementary perspectives: the application of quantum computing to emission tomography reconstruction, the system-level analysis of Single Photon Emission Computed Tomography (SPECT) imaging operators through null space characterization, and the use of Quantum Annealing (QA) for feature selection in medical imaging. Emission tomography enables the visualization of biological processes by detecting radiation emitted from a radiopharmaceutical administered to a patient. Reconstructing the spatial distribution of radiotracer activity from the acquired projection data constitutes a high-dimensional, ill-posed inverse problem that is further complicated by photon noise, attenuation, and incomplete angular sampling. Traditional iterative reconstruction methods, while effective, face challenges related to convergence, noise amplification, and sensitivity to system modeling assumptions. The first contribution of this thesis explores the feasibility of QA for emission tomography image reconstruction. The least-squares reconstruction problem is formulated as a Quadratic Unconstrained Binary Optimization (QUBO) model and solved using a hybrid quantum-classical solver. The method is evaluated on synthetic binary and integer-valued images of varying size, bit depth, and noise. Experiments on the D-Wave quantum annealer demonstrate that binary reconstructions are feasible for small image sizes directly on the quantum processing unit, while a hybrid solver extends the tractable image size to 32 × 32 pixels. However, scaling to higher bit depths introduces heterogeneous high-frequency noise and reveals classical bottlenecks in QUBO construction. To address the artifacts observed at increased bit depth, the second contribution introduces regularization techniques compatible with the QA formulation. Specifically, L2 and Total Variation (TV) regularization terms are incorporated into the optimization objective. These regularization strategies enforce smoothness and edge preservation in the reconstructed images and are shown to substantially improve reconstruction fidelity under the constrained discrete optimization framework, although the results remain below the quality achievable by conventional filtered backprojection. The third contribution shifts the focus from quantum-based reconstruction to a system-level analysis of SPECT imaging operators. The null space of the projection operator, which comprises all image components that are invisible to the measurement process, is computed for realistic three-dimensional (3-D) SPECT systems using an iterative Landweber-type algorithm. The analysis encompasses both conventional parallel-hole and multi-focal collimator geometries, including SMARTZOOM™ configurations used in cardiac and neurological imaging. The influence of acquisition parameters such as the number of projection views, angular sampling density, and depth-dependent point spread function modeling is systematically evaluated. Experiments on quality-control and anthropomorphic phantoms reveal that the null space is minimized by increasing angular coverage and finer sampling, and that point spread function modeling introduces characteristic ring-like structures in the null space corresponding to known reconstruction artifacts. The fourth contribution extends the use of QA to a related inverse problem: feature selection for image reconstruction. Rather than reconstructing the image directly, the objective is to identify a subset of the most informative pixels from medical images using a mutual information-based QUBO formulation. To make the problem compatible with current quantum hardware, the QUBO is spatially subsampled and sparsified to respect the limited qubit connectivity of the D-Wave Pegasus topology, and a soft linear constraint enforces the selection of a fixed number of features. The selected pixels serve as a compressed representation that is used to train a convolutional decoder for image reconstruction. Experiments on the MedMNIST benchmark demonstrate that the QA-based feature selection achieves performance comparable to classical QUBO simulations and outperforms several conventional pixel-level feature selection methods, while deep learning-based feature extractors yield higher reconstruction quality at the expense of interpretability. Overall, this thesis contributes to the understanding of how emerging quantum technologies can be applied to medical image reconstruction and related inverse problems, and provides a framework for evaluating the fundamental limitations of emission tomography systems through null space analysis.
Background Cancer is a leading cause of death worldwide. While routine diagnosis of cancer is performed mainly with biopsy sampling, it is suboptimal to accurately characterize tumor heterogeneity. Positron emission tomography (PET)-driven radiomic research has demonstrated promising results when predicting clinical endpoints. This study aimed to investigate the added value of quantum machine learning both in simulator and in real quantum computers utilizing error mitigation techniques to predict clinical endpoints in various PET cancer patients. Methods Previously published PET radiomics datasets including 11C-MET PET glioma, 68GA-PSMA-11 PET prostate and lung 18F-FDG PET with 3-year survival, low-vs-high Gleason risk and 2-year survival as clinical endpoints respectively were utilized in this study. Redundancy reduction with 0.7, 0.8, and 0.9 Spearman rank thresholds (SRT), followed by selecting 8 and 16 features from all cohorts, was performed, resulting in 18 dataset variants. Quantum advantage was estimated by Geometric Difference (GD Q ) score in each dataset variant. Five classic machine learning (CML) and their quantum versions (QML) were trained and tested in simulator environments across the dataset variants. Quantum circuit optimization and error mitigation were performed, followed by training and testing selected QML methods on the 21-qubit IonQ Aria quantum computer. Predictive performances were estimated by test balanced accuracy (BACC) values. Results On average, QML outperformed CML in simulator environments with 16-features (BACC 70% and 69%, respectively), while with 8-features, CML outperformed QML with + 1%. The highest average QML advantage was + 4%. The GD Q scores were ≤ 1.0 in all the 8-feature cases, while they were > 1.0 when QML outperformed CML in 9 out of 11 cases. The test BACC of selected QML methods and datasets in the IonQ device without error mitigation (EM) were 69.94% BACC, while EM increased test BACC to 75.66% (76.77% in noiseless simulators). Conclusions We demonstrated that with error mitigation, quantum advantage can be achieved in real existing quantum computers when predicting clinical endpoints in clinically relevant PET cancer cohorts. Quantum advantage can already be achieved in simulator environments in these cohorts when relying on QML.