Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Polarization-gradient optical pumping in an atomic magnetometer

Xiaona Liu, Yujie Sun, Zhaoying Wang

Published Apr 28, 2026• 0 citations
Publisher

Abstract

High-precision Mz/Mx atomic magnetometers have “dead zones”, where the magnetic-field information will be lost because the light–atom interaction vanishes at specific field angles. To suppress dead zones, we propose a scheme with polarization-gradient optical pumping field by using counter-propagating lin⊥lin beams. We found through experiments that the lin⊥lin scheme eliminates dead zones in the transverse plane of the probe beam propagation (minimum ∼40% normalized signal) but leaves two noncanonical magic-angle-like directions (≈30 ∘ and 150 ∘ ) in the longitudinal plane, which is distinct from the standard tensor magic angle (≈54 ∘ and 126 ∘ ). These observations are quantitatively explained using a multipole-based model formulated in terms of an effective, spatially averaged density matrix, which is the first time that the spatial average density matrix has been used for energy state analysis in atomic magnetometers. Under the probing of a linearly polarized light, the measured signal is determined by the field-angle-dependent projection of the atomic longitudinal alignment moment ( m 2,0 ) onto the B 0 -defined quantization axis. Compared with other dead-zone elimination schemes, our scheme avoids polarization modulation and multi-cell architectures, showing potential for improving the spatial response range of compact atomic magnetometry.

DOI
10.1364/ol.599327

Related papers

Dead-zone-free orientation-based pulsed atomic magnetometer

Jinghong Xu, Liwei Jiang, Yuntian Zou +6 more

The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.

Physical Review Research•Apr 6, 2026•0 citations

Dead-zone-free atomic magnetometer based on hybrid Poincaré beams

Ke Tian, Weifeng Ding, Zhaoying Wang

In this paper, we present the experiment and the theory scheme of light-atom interaction in atomic magnetometers by using a hybrid Poincaré beam (HPB) to solve an annoying problem, named “dead zone.” This kind of magnetometer can be sensitive to arbitrary directions of external magnetic fields. The HPB has a complex polarization distribution, consisting of a vector radially polarized beam and a scalar circularly polarized beam in our experiment. These two kinds of beams have different directions of dead zones of external magnetic fields; thereby, the atomic magnetometer with an HPB can avoid the non-signal area when the direction of the external magnetic field is in the plane perpendicular to the light polarization plane. Furthermore, the optical magnetic resonance (OMR) signal using an HPB still has no dead zones even when the direction of the external magnetic field is in the plane parallel to the polarization plane in our scheme. Our work has the potential to simplify and optimize dead-zone-free atomic magnetometers.

Photonics Research•Mar 4, 2024•16 citations

Dead-Zone-Free Atomic Magnetometry with Simultaneous Excitation of Orientation and Alignment Resonances

Amit Ben-Kish, Michael V. Romalis

Atomic magnetometers have very high absolute precision and sensitivity to magnetic fields but suffer from a fundamental problem: the vectorial or tensorial interaction of light with atoms leads to "dead zones," certain orientations of the magnetic field where the magnetometer loses its sensitivity. We demonstrate a simple polarization modulation scheme that simultaneously creates coherent population trapping (CPT) in orientation and alignment, thereby eliminating dead zones. Using 87Rb in a 10 Torr buffer gas cell we measure narrow, high-contrast CPT transparency peaks for all orientations and also show the absence of systematic effects associated with nonlinear Zeeman splitting.

arXiv:1001.0345•Physical Review Letters•Nov 4, 2010•87 citations

Dead-zone-free single-beam atomic magnetometer based on free-induction-decay of Rb atoms

Shrey Mehta, G. K. Samanta, Raghwinder Singh Grewal

Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.

arXiv:2410.15663•Applied Physics Letters•Jan 27, 2025•8 citations

Light-Shift-Free and Dead-Zone-Free Atomic-Orientation-Based Scalar Magnetometry Using a Single Amplitude-Modulated Beam

Q.-Q. Yu, S.-Q. Liu, C.-Q. Yuan +1 more

The detection dead zones and heading errors induced by light shifts are two important problems in optically pumped scalar magnetometry. We introduce an atomic-orientation-based single-beam magnetometry scheme to simultaneously solve these problems, using a polarization-reversing and path-bending Herriott cavity. Here, a reflection mirror is inserted into the cavity to bend the optical paths in the middle and divide them into two separated orthogonal regions to avoid the detection dead zone. Moreover, half-wave plates are added in the center of each optical region, so that the light polarization is flipped each time it passes the wave plates and the light-shift effects are spatially averaged out. This operation is demonstrated to eliminate the unnoticed heading errors induced by ac light shifts. The methods developed in this paper are robust to use and easy to apply other atomic devices.

arXiv:2205.08136•Physical Review Applied•Jul 7, 2022•25 citations

Suppression of mechanical error in micro-rotation-angle measurement of optical pumped atomic magnetometers

Huiyu Li, Kaibin Cui, Yu Wang +1 more

The measurement of ultra-weak magnetic fields relies on the conversion of magnetic field information to atom spins using alkali metals. In this context, the detection of magnetic fields is accomplished through rotation angle measurement of linearly polarized light. This paper proposes a novel method to suppress mechanical errors between polarizers in the rotation angle measurement, taking advantage of the optical setup characteristics in atomic magnetometers. The method involves applying two separate frequency modulations to the pump beam and probe beam, effectively eliminating mechanical errors between the polarizers as a direct current component using a double-channel lock-in amplifier. Additionally, the double modulation method offers a solution to suppress shot noise caused by incident beam fluctuations or transverse spin relaxation, as well as mechanical errors among optical elements in the light path, enabling high-precision measurements.

Tenth International Conference on Information Optics and Photonics•Nov 24, 2023•0 citations
High-precision Mz/Mx atomic magnetometers have “dead zones”, where the magnetic-field information will be lost because the light–atom interaction vanishes at specific field angles. To suppress dead zones, we propose a scheme with polarization-gradient optical pumping field by using counter-propagating lin⊥lin beams. We found through experiments that the lin⊥lin scheme eliminates dead zones in the transverse plane of the probe beam propagation (minimum ∼40% normalized signal) but leaves two noncanonical magic-angle-like directions (≈30 ∘ and 150 ∘ ) in the longitudinal plane, which is distinct from the standard tensor magic angle (≈54 ∘ and 126 ∘ ). These observations are quantitatively explained using a multipole-based model formulated in terms of an effective, spatially averaged density matrix, which is the first time that the spatial average density matrix has been used for energy state analysis in atomic magnetometers. Under the probing of a linearly polarized light, the measured signal is determined by the field-angle-dependent projection of the atomic longitudinal alignment moment ( m 2,0 ) onto the B 0 -defined quantization axis. Compared with other dead-zone elimination schemes, our scheme avoids polarization modulation and multi-cell architectures, showing potential for improving the spatial response range of compact atomic magnetometry.
The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.
In this paper, we present the experiment and the theory scheme of light-atom interaction in atomic magnetometers by using a hybrid Poincaré beam (HPB) to solve an annoying problem, named “dead zone.” This kind of magnetometer can be sensitive to arbitrary directions of external magnetic fields. The HPB has a complex polarization distribution, consisting of a vector radially polarized beam and a scalar circularly polarized beam in our experiment. These two kinds of beams have different directions of dead zones of external magnetic fields; thereby, the atomic magnetometer with an HPB can avoid the non-signal area when the direction of the external magnetic field is in the plane perpendicular to the light polarization plane. Furthermore, the optical magnetic resonance (OMR) signal using an HPB still has no dead zones even when the direction of the external magnetic field is in the plane parallel to the polarization plane in our scheme. Our work has the potential to simplify and optimize dead-zone-free atomic magnetometers.
Atomic magnetometers have very high absolute precision and sensitivity to magnetic fields but suffer from a fundamental problem: the vectorial or tensorial interaction of light with atoms leads to "dead zones," certain orientations of the magnetic field where the magnetometer loses its sensitivity. We demonstrate a simple polarization modulation scheme that simultaneously creates coherent population trapping (CPT) in orientation and alignment, thereby eliminating dead zones. Using 87Rb in a 10 Torr buffer gas cell we measure narrow, high-contrast CPT transparency peaks for all orientations and also show the absence of systematic effects associated with nonlinear Zeeman splitting.
Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.
The detection dead zones and heading errors induced by light shifts are two important problems in optically pumped scalar magnetometry. We introduce an atomic-orientation-based single-beam magnetometry scheme to simultaneously solve these problems, using a polarization-reversing and path-bending Herriott cavity. Here, a reflection mirror is inserted into the cavity to bend the optical paths in the middle and divide them into two separated orthogonal regions to avoid the detection dead zone. Moreover, half-wave plates are added in the center of each optical region, so that the light polarization is flipped each time it passes the wave plates and the light-shift effects are spatially averaged out. This operation is demonstrated to eliminate the unnoticed heading errors induced by ac light shifts. The methods developed in this paper are robust to use and easy to apply other atomic devices.
The measurement of ultra-weak magnetic fields relies on the conversion of magnetic field information to atom spins using alkali metals. In this context, the detection of magnetic fields is accomplished through rotation angle measurement of linearly polarized light. This paper proposes a novel method to suppress mechanical errors between polarizers in the rotation angle measurement, taking advantage of the optical setup characteristics in atomic magnetometers. The method involves applying two separate frequency modulations to the pump beam and probe beam, effectively eliminating mechanical errors between the polarizers as a direct current component using a double-channel lock-in amplifier. Additionally, the double modulation method offers a solution to suppress shot noise caused by incident beam fluctuations or transverse spin relaxation, as well as mechanical errors among optical elements in the light path, enabling high-precision measurements.