Interferometric studies in the transportable Quantum Gravimeter QG-1
Nina Heine
Abstract
Pioneering work on cold atom based quantum sensors introduced new measurement concepts to geosciences, promising independent tests of established methods as well as showing unprecedented stability, in the case of gravimetry. This naturally raises the question, whether unprecedented stability could be paired with unprecedented accuracy. Unfortunately, systematic effects originating from the thermal expansion and horizontal motion of the cold atom source prohibit this intrinsically. However, employing delta-kick collimated Bose-Einstein Condensates (BECs) instead, these leading order uncertainty contributions, i.e. wavefront aberrations and the Coriolis contribution, can be overcome. One of the major challenges here is to minimise the sensor size and power consumption to allow for mobile operation. This thesis elaborates on the development of a transportable BEC gravimeter referred to as the Quantum Gravimeter QG-1. A compact sensor size is realized by using an atom-chip based BEC source. The source performance is optimised at two operation locations producing samples of > 10^5 87Rb atoms after less than 1 s of evaporation time. The evaporation procedure is optimised for minimal residual centre-of-mass oscillation. Subsequently the atoms are released from the magnet trap, delta-kick collimated by a magnetic potential and prepared for interferometry by state transfer and purification. After this procedure up to 10^5 atoms remain in the desired, to first order, magnetically insensitive mF = 0 state, exhibiting an effective temperature of 19.8 nK in the z and 400 pK in the y direction. With this source atom interferometers of high fringe contrast of > 90 % could be operated for pulse separation times of up to 60 ms. The main focus of this work lies on the analysis of the first test of long-term operation. For this purpose the instrument was operated for eight consecutive days. This comprises a new milestone for the interruption-free operability of BEC gravimeters. The acceleration signal’s instability reveals a pressure-dependent long-term drift, which originated from the reference oscillator. Environmental and experimental data is used to correct the acceleration signal. This method reduces the long-term instability to the expected 1/√𝜏 behaviour and reveals correlation of the remaining instability with the sample’s position stability. The acceleration spectral density indicates a limitation of the short-term instability by residual vibrations of the passive isolation platform. The analysis procedure itself is evaluated by comparison of three different approaches of image evaluation. The important role of spatially resolving detection in the analysis of sources of instability, as well as in the characterisation of systematic effects is highlighted by application to setting an upper bound on the uncompensated Coriolis contribution and second order Zeeman shift. Future benefits of image-based detection for characterising systematics, such as wavefront aberrations, as well as its role in the alignment of the interferometer with respect to gravity are pointed out. Strategies for suppressing a phase shift originating from the BEC’s mean-field energy are introduced. These findings are a profound basis for entering the commissioning phase of the device, which includes the establishment of an initial uncertainty budget, the development of standardized measurement and evaluation procedures, the participation in comparisons and the preparation of measurement campaigns.