Inertial sensors based on matter-wave interferometry are currently approaching the precision and accuracy of state-of-the-art classical sensors. While these devices are often realised with ultracold but not Bose-condensed atoms as matter waves, employing Bose-Einstein Condensates (BEC) promises to overcome certain limitations, especially those related to the ensemble's expansion. The point-source like character of BECs also enables utilising spatial interference patterns to measure e.g. rotation rates in single-shot experiments. Matter wave-based inertial sensors are considered for experiments ranging from Gravitational Wave detection to tests of the Universality of Free Fall (UFF) to gain insight into the joint between Quantum Mechanics and General Relativity. In the scope of this thesis, matter-wave interferometry with BECs was demonstrated for the first time in a microgravity environment with the QUANTUS-1 apparatus. The same instrument was then employed as a quantum tiltmeter utilising a novel beam-splitting mechanism known as Bragg Double Diffraction. To this end, the QUANTUS-1 apparatus designed as a BEC instrument to be operated in the drop tower at ZARM at University of Bremen was equipped with optics and laser systems required for performing matter-wave interferometry based on Bragg Diffraction. The apparatus employs an atom chip to create BECs of around 10000 Rubidium 87 atoms within 15 s. With a Mach-Zehnder like interferometer scheme, spatial interference fringes were observed after a free evolution time in the interferometer of up to 677 ms. To achieve these long time scales, a method known as Delta-Kick Collimation (DKC) was adapted to slow the expansion of the BEC to a kinetic energy equivalent below 1 nK, and the atoms were transferred to a non-magnetic Zeeman state via an adiabatic rapid passage (ARP). A similar interferometer scheme with a newly developed beam-splitter mechanism known as Bragg Double Diffraction was used to measure the tilt of the instrument on ground with a precision of up to 4.4 AA rad. This thesis presents an overview of the apparatus including ground-based characterisations of all required experimental steps. Results from over 400 free fall experiments are evaluated for expansion studies of the BEC and matter-wave interferometry in microgravity. The time-evolution of first and second order Bragg Double Diffraction beam splitters is studied, and an interferometer sensitive to the tilt of the instrument is implemented. Based on this work, a gravimeter with a new launch mechanism comprising Bragg beam splitters and Bloch oscillations to enable atomic fountains in atom-chip based devices was developed. The microgravity experiments were adapted for the MAIUS-1 sounding-rocket instrument to create the first man-made BEC in outer space and study the feasibility of operating matter-wave interferometers on space-borne platforms. The results of this thesis lay the groundwork for future space-borne missions using matter-wave interferometry for precision measurements of inertial forces.
Inertial sensors based on matter-wave interferometry are currently approaching the precision and accuracy of state-of-the-art classical sensors. While these devices are often realised with ultracold but not Bose-condensed atoms as matter waves, employing Bose-Einstein Condensates (BEC) promises to overcome certain limitations, especially those related to the ensemble's expansion. The point-source like character of BECs also enables utilising spatial interference patterns to measure e.g. rotation rates in single-shot experiments. Matter wave-based inertial sensors are considered for experiments ranging from Gravitational Wave detection to tests of the Universality of Free Fall (UFF) to gain insight into the joint between Quantum Mechanics and General Relativity. In the scope of this thesis, matter-wave interferometry with BECs was demonstrated for the first time in a microgravity environment with the QUANTUS-1 apparatus. The same instrument was then employed as a quantum tiltmeter utilising a novel beam-splitting mechanism known as Bragg Double Diffraction. To this end, the QUANTUS-1 apparatus designed as a BEC instrument to be operated in the drop tower at ZARM at University of Bremen was equipped with optics and laser systems required for performing matter-wave interferometry based on Bragg Diffraction. The apparatus employs an atom chip to create BECs of around 10000 Rubidium 87 atoms within 15 s. With a Mach-Zehnder like interferometer scheme, spatial interference fringes were observed after a free evolution time in the interferometer of up to 677 ms. To achieve these long time scales, a method known as Delta-Kick Collimation (DKC) was adapted to slow the expansion of the BEC to a kinetic energy equivalent below 1 nK, and the atoms were transferred to a non-magnetic Zeeman state via an adiabatic rapid passage (ARP). A similar interferometer scheme with a newly developed beam-splitter mechanism known as Bragg Double Diffraction was used to measure the tilt of the instrument on ground with a precision of up to 4.4 AA rad. This thesis presents an overview of the apparatus including ground-based characterisations of all required experimental steps. Results from over 400 free fall experiments are evaluated for expansion studies of the BEC and matter-wave interferometry in microgravity. The time-evolution of first and second order Bragg Double Diffraction beam splitters is studied, and an interferometer sensitive to the tilt of the instrument is implemented. Based on this work, a gravimeter with a new launch mechanism comprising Bragg beam splitters and Bloch oscillations to enable atomic fountains in atom-chip based devices was developed. The microgravity experiments were adapted for the MAIUS-1 sounding-rocket instrument to create the first man-made BEC in outer space and study the feasibility of operating matter-wave interferometers on space-borne platforms. The results of this thesis lay the groundwork for future space-borne missions using matter-wave interferometry for precision measurements of inertial forces.
Matter-wave sensors are considered to be one of the most promising fields for progress in metrology and fundamental tests. We report on the development of a miniaturized and robust experiment within the QUANTUS collaboration using ultra cold atoms in a free fall environment as a test-bed for matter-wave interferometry on long timescales. Over 200 experiments in microgravity have been performed so far at the ZARM drop tower in Bremen and a BEC was observed after expansion times of up to 1s. The combination of long expansion times and low density samples is beneficial for the application in interferometry. We present the recently implemented interferometer in our chip-based87Rb BEC experiment including on-chip state preparation. Bragg diffraction is used for coherent manipulation, realizing different interferometer schemes. First results on ground and in microgravity are shown.
Quantum sensors based on the interference of cold atoms have advanced to the forefront of precision measurements in geodesy, metrology and tests of fundamental physics. The ultimate potential of these devices is realized using quantum degenerate atoms in extended free fall. This can be achieved on microgravity platforms such as drop towers, parabolic flights, ballistic rockets, satellites and space stations. The transition to mobile and robust devices that can withstand the demands of these environments comes with many challenges. Quantum sensors need to be scaled down and integrated without compromising their performance. In fact, they need to significantly outpace conventional instruments, since microgravity time is an expensive resource and limited to a few seconds at a time on the most accessible platforms. This thesis describes the construction, qualification and operation of a miniaturized ultracold atom experiment that meets these challenges. The QUANTUS-2 apparatus features a payload weight of 147 kg and a payload volume of 0.3 m^3. It generates Bose-Einstein condensates of 4×10^5 ^87Rb atoms every 1.6 seconds, a flux of ultra-cold atoms that is on par with the best lab-sized devices. Ensembles of 1×10^5 atoms can be created at a 1 Hz rate. It is currently the fastest machine of its kind and achieves the highest atom number of any atom chip setup. The apparatus continuously withstands peak accelerations of up to 45 g during microgravity campaigns at the drop tower facility in Bremen, Germany. Here, the payload has accrued 208 drops and 9 catapult launches over 24 month. The setup is the first atom optics experiment to stand up to the technical demands of catapult operation. Four condensates can be created and observed consecutively during nine seconds of free fall in a single catapult launch. In total, the experiment has been suspended in microgravity for over 17 minutes. With the record source performance, the repetition rate for microgravity experiments with ultra-cold atoms was increased by a factor of four compared to previous devices. The total atom number was increased by a factor of 40, vastly improving the signal to noise ratio for absorption images of spatially extended clouds. The ensembles can be prepared consistently over many weeks of drop tower operation. The variance of the mean center of mass velocity in two observable directions is 7.3 μm/s and 6.9 μm/s. Magnetic lensing techniques were employed to manipulate the expansion of the ensembles. First results yield a residual expansion rate in three dimensions of σ_v = 116.9 ± 13.9 μm/s, which implies a three-dimensional effective temperature of T = 47.6 ± 11.3 pK at an average condensate atom number of N = 93000. These values constitute the best collimation of any atomic ensemble and the most promising source for atom interferometry reported to date. Optimizing the current lensing sequence will reduce the expansion rate further to effective temperatures in the femtokelvin regime. The level of control demonstrated over the condensates is highly relevant for the advancement of matter-wave optics and quantum sensors. Controlling the motion and size of atomic clouds is intrinsically tied to many systematic effects in high precision measurements. QUANTUS-2 will provide a platform to explore and mitigate these limitations on unprecedented time scales of up to seven seconds of free evolution.
A precision inertial sensor based on the interference of matter waves has been designed and implemented. The apparatus is capable of producing both cold thermal and ultracold Bose-Einstein condensate (BEC) atomic ensembles as the inertial test mass. BECs of up to 5x10^6 Rubidium 87 atoms with an effective temperature of 50nK are produced every 13 seconds using a combination of two and three dimensional magneto-optical traps (2D and 3D MOT) and evaporative cooling in a hybrid magnetic-quadrupole and crossed optical dipole trap. The atomic cloud is then propagated through a vertically oriented Mach-Zehnder interferometer utilizing Bragg diffraction beam splitters. An 2.6m drop tube allows for up to 750ms of free fall and interferometer times of up to 250ms. The drop has four regions of imaging corresponding to 0, 25, 220, 530, and 750ms of expansion. Standard absorption imaging is used for the upper two imaging regions and frequency modulation imaging (FMI) is used for the lower regions. FMI exhibits near atom-shot noise limited signal-to-noise of 948 on a 1x10^6 atom cloud. The inertial reference is provided by the Bragg beam retro-reflector which is suspended via a geometric anti-spring passive vibration isolation system providing 65 dB of isolation at 70 Hz. Prior to the first interferometer pulse the ensemble is placed into a spin superposition of the |F=1> ground state manifold using horizontal co-propagating Raman beams. The three internal spin states remain orthogonal throughout the interferometer sequence resulting in three simultaneous interferometer with separable magnetic gradient and gravitational acceleration signals. The effects of meanfield energy on the interferometric phase uncertainty is explored under current trap conditions. It is found that 30 ms of free expansion prior to the first beam splitter decreases the internal energy such that the expected meanfield phase noise is below 1mrad. No significant decrease in the interferometer contrast is observed for all available T, whereas a thermal test mass interferometer of equivalent longitudinal temperature produces no interference at interferometer times > 100ms. A direct comparison of test mass spatial coherence length in an optically transversely confined interferometer is investigated. The visibility and contrast of a BEC and three thermal sources with varying spatial coherence are compared as a function of interferometer time. At short times, the fringe visibility of a BEC source approaches 100%, nearly independent of p pulse efficiency, while thermal sources have fringe visibilities limited to the p pulse efficiency. More importantly for precision measurement systems, the BEC source maintains interference at interferometer times significantly beyond that of the thermal source. A BEC test mass is used for the simultaneous precision measurement of gravity and magnetic field gradients. An 8 hour data run of a 130ms interferometer shows good agreement between the interferometer output and a theoretical model of the solid earth tides. The residual of the theoretical model and the experimental data show a 1000 run precision of dg/g = 1.45x10^9 corresponding to a phase noise of 3.8mrad. The integrated phase noise of the apparatus shows a sensitivity to magnetic field gradients of 120pT/m. By varying the central spatial position of a 40ms interferometer the magnetic field gradient along a portion of the drop tube is measured.
Matter-wave interferometers show great a potential for improving inertial sensing. The absence of drifts recommends them for a variety of applications in geodesy, navigation, or fundamental physics. Here, ultracold atomic ensembles, featuring a velocity distribution well below the photon recoil velocity, open up new perspectives. In contrast to standard laser cooling methods, they allow to reach better beam-splitting efficiencies and, hence, a higher contrast as well as to reduce systematic uncertainties and biases. Presently, Bose-Einstein condensates (BECs) provide the means to achieve the lowest expansion energies of few picokelvin. Indeed, the momentum distribution of a BEC can be further narrowed after reaching the regime of ballistic expansion, where all mean field energy is converted to kinetic energy, by the application of the delta-kick collimation technique. With such ensembles, Bragg processes can be driven with an efficiency of above 95% as well as Bloch oscillations performed without large atomic losses or dephasing. Both enable efficient large momentum transfer in interferometers to enhance their sensitivity for inertial effects. In a so-called twin-lattice atom interferometers more than thousand photon recoils are used to form compact but sensitive atom interferometers. These methods not only bring in reach extremely accurate gravimeters and accelerometers but also gyroscopes. Like the Sagnac effect in ring laser or fiber gyroscopes, the sensitivity of atom interferometers to rotations increases with the space-time area enclosed by the interferometer. In the case of light interferometers, the latter can be enlarged by forming multiple fiber loops. However, the equivalent for matter-wave interferometers remains an experimental challenge. An atom interferometer with scalable area may be formed in a twin lattice combined with a relaunch mechanism to obtain multi loops as well. Due to this scalability, it offers the perspective of reaching unprecedented sensitivities for rotations in comparably compact sensor head setups. Moreover, atom-chip technologies offer the possibility to generate a BEC and perform delta-kick collimation in a fast and reliable away, paving the way for field-deployable miniaturized atomic devices. Last but not least, the extremely low expansion energies of BECs open up to extend the time atoms spend in the interferometer to tens of seconds. This brings in reach unprecedented sensitivities in space-borne applications such as satellite geodesy.
Bose-Einstein condensates (BECs) in free fall constitute a promising source for space-borne interferometry. Indeed, BECs enjoy a slowly expanding wave function, display a large spatial coherence and can be engineered and probed by optical techniques. Here we explore matter-wave fringes of multiple spinor components of a BEC released in free fall employing light-pulses to drive Bragg processes and induce phase imprinting on a sounding rocket. The prevailing microgravity played a crucial role in the observation of these interferences which not only reveal the spatial coherence of the condensates but also allow us to measure differential forces. Our work marks the beginning of matter-wave interferometry in space with future applications in fundamental physics, navigation and earth observation.
Bose-Einstein condensates (BECs) in free fall constitute a promising source for space-borne interferometry. Indeed, BECs enjoy a slowly expanding wave function, display a large spatial coherence and can be engineered and probed by optical techniques. Here we explore matter-wave fringes of multiple spinor components of a BEC released in free fall employing light-pulses to drive Bragg processes and induce phase imprinting on a sounding rocket. The prevailing microgravity played a crucial role in the observation of these interferences which not only reveal the spatial coherence of the condensates but also allow us to measure differential forces. Our work marks the beginning of matter-wave interferometry in space with future applications in fundamental physics, navigation and earth observation.