Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Photonics

Metasurface-Assisted Rydberg-Atom Sensor with Wavefront Shaping and Enhanced Sensitivity

Hao Zhang, Zhen Chen, Jun Huang, Jianjun Chen, Wenguang Yang, Mingyong Jing, Zongkai Liu, Junyao Xie, Liantuan Xiao, Suotang Jia, Linjie Zhang

Published Apr 1, 2026• 1 citation
Publisher

Abstract

Rydberg-atom electric-field sensors have emerged as an important research direction in quantum precision measurement, owing to their intrinsic SI traceability, noninvasive measurement capability, and wide frequency tunability. However, under free-space conditions, the geometric divergence of microwaves (MWs) limits the practical detection performance of the system. In this work, we propose and experimentally demonstrate a metasurface-assisted Rydberg-atom hybrid sensor. Through introducing wavefront shaping of the incident microwave field with a metasurface (MS), electric-field enhancement in the atomic sensing region is achieved. Without altering the intrinsic sensitivity of the Rydberg-atom sensor, the equivalent sensitivity of the hybrid sensor is improved to 57.3nVcm−1Hz−1/2. This scheme provides a new route toward high-sensitivity, integrated quantum sensing of the microwave electric field.

DOI
10.3390/photonics13040343

Related papers

Sensitivity Enhancement of S-Band Rydberg Atom Microwave Receiver Using Resonant Cavity

Yipeng Xie, Xinbing Chen, Mingwei Lei +1 more

Rydberg atom-based microwave electric field sensing has attracted growing interest owing to its inherent advantages, such as absolute calibration, wideband operability, and compatibility with room-temperature devices. A critical bottleneck that limits sensitivity is the inefficient coupling between the Rydberg atoms and the incident microwave field, particularly when detecting weak signals propagating in free space. Here we propose and experimentally validate a scheme that integrates a horn antenna with a resonant microwave cavity to significantly improve this coupling for free-space signal reception in the S-band. Using a two-photon excitation scheme in a cesium vapor cell, we systematically characterize the sensing performance under three configurations: a bare cell, direct cavity injection, and a cavity coupled to a horn antenna that captures free-space microwave signals over a 1 m distance. In the antenna-coupled cavity configuration, we achieve an optimal sensitivity of 2.33 nV/cm/$\sqrt{\text{Hz}}$ at the receiving antenna, which corresponds to an enhancement of approximately 17.9 dB compared to the optimized bare vapor cell configuration. Our findings offer a practical and effective route to boost the sensitivity of Rydberg atomic sensors, facilitating their adoption in real-world microwave metrology and wireless communication applications where weak free-space electric fields must be reliably measured.

physics.atom-phCross-listedarXiv:2606.02669•Optics Express•Jun 2, 2026•0 citations

Quantum sensing of microwave electric fields based on Rydberg atoms

Jinpeng Yuan, Wenguang Yang, Mingyong Jing +6 more

Microwave electric field (MW E-field) sensing is important for a wide range of applications in the areas of remote sensing, radar astronomy and communications. Over the past decade, Rydberg atoms have been used in ultrasensitive, wide broadband, traceable, stealthy MW E-field sensing because of their exaggerated response to MW E-fields, plentiful optional energy levels and integratable preparation methods. This review first introduces the basic concepts of quantum sensing, the properties of Rydberg atoms and the principles of quantum sensing of MW E-fields with Rydberg atoms. An overview of this very active research direction is gradually expanding, covering the progress of sensitivity and bandwidth in Rydberg atom-based microwave sensing, superheterodyne quantum sensing with microwave-dressed Rydberg atoms, quantum-enhanced sensing of MW E-field and recent advanced quantum measurement systems and approaches to further improve the performance of MW E-field sensing. Finally, a brief outlook on future development directions is provided.

arXiv:2401.01655•Reports on Progress in Physics•Aug 21, 2023•95 citations

Cavity-Enhanced Rydberg Atom Microwave Receiver

Bang Liu, Lihua Zhang, Qifeng Wang +11 more

Abstract Developing microwave electric field sensing based on Rydberg atoms has received significant attention due to its unique advantages. However, achieving effective coupling between Rydberg atoms and the microwave electric field in the sensing process is a challenging problem that greatly impacts the sensitivity. To address this, we propose using a microwave resonant cavity to enhance the effective coupling between the Rydberg atoms and the microwave electric field. In our experiment, Rydberg atoms are prepared via a three-photon excitation scheme, and the electric fields are measured without and with a microwave cavity in which the vapor cell is placed inside, respectively. As a result, we achieved an 18 dB enhancement of power sensitivity by adding the cavity, which is an effective enhancement in electric field pulse signal detection. This experimental testing provides a promising direction for enhancing the sensitivity of Rydberg atomic electric field sensors and paves the way for their application in precision electric field measurements.

arXiv:2404.06915•Chinese Physics Letters•Apr 7, 2025•26 citations

Atom-based sensing of microwave electric fields using highly excited atoms: mechanisms affecting sensitivity

James P. Shaffer, Harald Kübler, James Keaveney +5 more

We have shown that Rydberg states can be used for high-sensitivity, absolute sensing of microwave (MW) electric fields. We achieved a sensitivity of 3 μVcm-1Hz-1/2 for two read-out strategies. Depending on the spectral resolution of the read-out, either the MW induced transmission line frequency splitting, the Autler-Townes regime, or a change in the on-resonant absorption, the amplitude regime, can be used to determine the MW electric field. Results using a Mach-Zehnder interferometer and frequency modulated spectroscopy both achieve similar photon shot noise limited sensitivity. In addition, we have also explored amplitude modulation and the displacement of a probe laser beam due to index of refraction changes in a prism shaped vapor cell. These latter methods were not able to achieve photon shot noise limited performance. Fundamental limits to the sensitivity of the Rydberg atom-based MW electric field sensing have been addressed, but it is important to clarify the differences between noise in different parts or subsystems of the sensor. Shot noise in the probe laser usually dominates the projection noise of the atoms participating in the measurement of the MW electric field because of the desire to operate at low effective Rydberg atom densities in order to avoid collisional dephasing and ionization.

Optical and Quantum Sensing and Precision Metrology II•Mar 1, 2019•9 citations

High-Sensitivity Rydberg Atom-Based Field Sensing Enhancement Using Miniaturized Resonator

Aojie Zhou, Yi Lin, Ruiqi Mao +4 more

High-sensitivity amplitude and frequency detection of microwave electric fields is of significant importance in various fields, including communications, microwave quantum technology, aerospace, medicine, and meteorology. Rydberg atom-based sensors promise traceable standards and high sensitivity for detecting weak electric fields and enhancing sensing sensitivity, mainly by using superheterodyne technology and resonant structures. Detecting high-frequency (HF) band fields with high sensitivity using Rydberg atom sensors is a significant challenge due to the requirement of exciting atoms to extremely high energy states for resonant detection. We demonstrate the off-resonant Rydberg atomic superheterodyne architecture with additional resonators for greatly enhancing the sensing sensitivity to HF band fields. In this approach, we propose a miniaturized square spiral resonator with an electrical size of$0.011~\lambda $at 15.54 MHz. To reduce the electric-field-screening effect of the adsorption of alkali metal atoms, we use a monocrystalline sapphire cesium (Cs) vapor cell. By utilizing the off-resonant alternating current (ac) Stark effect, the initial sensitivity of the Rydberg atom sensor without the resonator is measured to be$10.39~\mu \text {V/cm}\sqrt {\text {Hz}}$at room temperature. With the addition of the miniaturized square spiral resonator, the sensitivity significantly improved to$2.60~\text {nV/cm}\sqrt {\text {Hz}}$, which has been inaccessible so far with atomic sensors. Here, we provide an enhancement of 72 dB, which is three orders of magnitude improvement in sensitivity than when the resonator is not used. This enhancement resonator extends Rydberg atomic high-sensitivity sensing to the HF band and shows great potential, especially in shortwave radio reception.

IEEE Transactions on Antennas and Propagation•Aug 13, 2025•9 citations

Enhanced sensing of 3.4 GHz microwave in multi-level Rydberg atomic system

Jingjing, Xue, Ruonan, Li, Hu Xuesong +3 more

The Rydberg-based microwave detection is an all-optical technology that uses the strong coherent interaction between Rydberg atoms and microwave field. Different from the traditional microwave meter, the Rydberg atomic sensing is a new-type microwave detector that transforms the microwave spectrum into a coherent optical spectrum, and arouses increasingly the interests due to its high sensibility. For this kind of sensor, the coherence effect induced by coupling atoms with microwave plays a key role, and the decoherence may reduce the sensitivity. A multi-level Rydberg atomic scheme with optimized quantum coherence, which enhances both the bandwidth and the sensitivity for 4 GHz microwave sensing, is demonstrated experimentally in this work. The enhanced quantum coherence of Rydberg electromagnetically induced transparency (EIT) and microwave induced Autler-Townes (AT) splitting in EIT windows are shown using optical pumping at D1 line. The enhanced sensitivity at 3.4 GHz with 0.3 GHz bandwidth can be realized, based on the enhanced EIT-AT spectrum. The experimental results show that in the stepped Rydberg EIT system, the spectral width of EIT and microwave field EIT-AT can be narrowed by optical pumping (OP), so the sensitivity of microwave electric field measurement can be improved. After optimizing the EIT amplitude and adding single-frequency microwaves, the sensitivity of the microwave electric field measurement observed by the AT splitting interval is improved by 1.3 times. This work provides a reference for utilizing atomic microwave detection.

arXiv:2508.01260•Aug 2, 2025•0 citations
Rydberg-atom electric-field sensors have emerged as an important research direction in quantum precision measurement, owing to their intrinsic SI traceability, noninvasive measurement capability, and wide frequency tunability. However, under free-space conditions, the geometric divergence of microwaves (MWs) limits the practical detection performance of the system. In this work, we propose and experimentally demonstrate a metasurface-assisted Rydberg-atom hybrid sensor. Through introducing wavefront shaping of the incident microwave field with a metasurface (MS), electric-field enhancement in the atomic sensing region is achieved. Without altering the intrinsic sensitivity of the Rydberg-atom sensor, the equivalent sensitivity of the hybrid sensor is improved to 57.3nVcm−1Hz−1/2. This scheme provides a new route toward high-sensitivity, integrated quantum sensing of the microwave electric field.
Rydberg atom-based microwave electric field sensing has attracted growing interest owing to its inherent advantages, such as absolute calibration, wideband operability, and compatibility with room-temperature devices. A critical bottleneck that limits sensitivity is the inefficient coupling between the Rydberg atoms and the incident microwave field, particularly when detecting weak signals propagating in free space. Here we propose and experimentally validate a scheme that integrates a horn antenna with a resonant microwave cavity to significantly improve this coupling for free-space signal reception in the S-band. Using a two-photon excitation scheme in a cesium vapor cell, we systematically characterize the sensing performance under three configurations: a bare cell, direct cavity injection, and a cavity coupled to a horn antenna that captures free-space microwave signals over a 1 m distance. In the antenna-coupled cavity configuration, we achieve an optimal sensitivity of 2.33 nV/cm/Hz\sqrt{\text{Hz}}Hz​ at the receiving antenna, which corresponds to an enhancement of approximately 17.9 dB compared to the optimized bare vapor cell configuration. Our findings offer a practical and effective route to boost the sensitivity of Rydberg atomic sensors, facilitating their adoption in real-world microwave metrology and wireless communication applications where weak free-space electric fields must be reliably measured.
Microwave electric field (MW E-field) sensing is important for a wide range of applications in the areas of remote sensing, radar astronomy and communications. Over the past decade, Rydberg atoms have been used in ultrasensitive, wide broadband, traceable, stealthy MW E-field sensing because of their exaggerated response to MW E-fields, plentiful optional energy levels and integratable preparation methods. This review first introduces the basic concepts of quantum sensing, the properties of Rydberg atoms and the principles of quantum sensing of MW E-fields with Rydberg atoms. An overview of this very active research direction is gradually expanding, covering the progress of sensitivity and bandwidth in Rydberg atom-based microwave sensing, superheterodyne quantum sensing with microwave-dressed Rydberg atoms, quantum-enhanced sensing of MW E-field and recent advanced quantum measurement systems and approaches to further improve the performance of MW E-field sensing. Finally, a brief outlook on future development directions is provided.
Abstract Developing microwave electric field sensing based on Rydberg atoms has received significant attention due to its unique advantages. However, achieving effective coupling between Rydberg atoms and the microwave electric field in the sensing process is a challenging problem that greatly impacts the sensitivity. To address this, we propose using a microwave resonant cavity to enhance the effective coupling between the Rydberg atoms and the microwave electric field. In our experiment, Rydberg atoms are prepared via a three-photon excitation scheme, and the electric fields are measured without and with a microwave cavity in which the vapor cell is placed inside, respectively. As a result, we achieved an 18 dB enhancement of power sensitivity by adding the cavity, which is an effective enhancement in electric field pulse signal detection. This experimental testing provides a promising direction for enhancing the sensitivity of Rydberg atomic electric field sensors and paves the way for their application in precision electric field measurements.
We have shown that Rydberg states can be used for high-sensitivity, absolute sensing of microwave (MW) electric fields. We achieved a sensitivity of 3 μVcm-1Hz-1/2 for two read-out strategies. Depending on the spectral resolution of the read-out, either the MW induced transmission line frequency splitting, the Autler-Townes regime, or a change in the on-resonant absorption, the amplitude regime, can be used to determine the MW electric field. Results using a Mach-Zehnder interferometer and frequency modulated spectroscopy both achieve similar photon shot noise limited sensitivity. In addition, we have also explored amplitude modulation and the displacement of a probe laser beam due to index of refraction changes in a prism shaped vapor cell. These latter methods were not able to achieve photon shot noise limited performance. Fundamental limits to the sensitivity of the Rydberg atom-based MW electric field sensing have been addressed, but it is important to clarify the differences between noise in different parts or subsystems of the sensor. Shot noise in the probe laser usually dominates the projection noise of the atoms participating in the measurement of the MW electric field because of the desire to operate at low effective Rydberg atom densities in order to avoid collisional dephasing and ionization.
High-sensitivity amplitude and frequency detection of microwave electric fields is of significant importance in various fields, including communications, microwave quantum technology, aerospace, medicine, and meteorology. Rydberg atom-based sensors promise traceable standards and high sensitivity for detecting weak electric fields and enhancing sensing sensitivity, mainly by using superheterodyne technology and resonant structures. Detecting high-frequency (HF) band fields with high sensitivity using Rydberg atom sensors is a significant challenge due to the requirement of exciting atoms to extremely high energy states for resonant detection. We demonstrate the off-resonant Rydberg atomic superheterodyne architecture with additional resonators for greatly enhancing the sensing sensitivity to HF band fields. In this approach, we propose a miniaturized square spiral resonator with an electrical size of$0.011~\lambda $at 15.54 MHz. To reduce the electric-field-screening effect of the adsorption of alkali metal atoms, we use a monocrystalline sapphire cesium (Cs) vapor cell. By utilizing the off-resonant alternating current (ac) Stark effect, the initial sensitivity of the Rydberg atom sensor without the resonator is measured to be10.39 μV/cmHz10.39~\mu \text {V/cm}\sqrt {\text {Hz}}10.39 μV/cmHz​at room temperature. With the addition of the miniaturized square spiral resonator, the sensitivity significantly improved to2.60 nV/cmHz2.60~\text {nV/cm}\sqrt {\text {Hz}}2.60 nV/cmHz​, which has been inaccessible so far with atomic sensors. Here, we provide an enhancement of 72 dB, which is three orders of magnitude improvement in sensitivity than when the resonator is not used. This enhancement resonator extends Rydberg atomic high-sensitivity sensing to the HF band and shows great potential, especially in shortwave radio reception.
The Rydberg-based microwave detection is an all-optical technology that uses the strong coherent interaction between Rydberg atoms and microwave field. Different from the traditional microwave meter, the Rydberg atomic sensing is a new-type microwave detector that transforms the microwave spectrum into a coherent optical spectrum, and arouses increasingly the interests due to its high sensibility. For this kind of sensor, the coherence effect induced by coupling atoms with microwave plays a key role, and the decoherence may reduce the sensitivity. A multi-level Rydberg atomic scheme with optimized quantum coherence, which enhances both the bandwidth and the sensitivity for 4 GHz microwave sensing, is demonstrated experimentally in this work. The enhanced quantum coherence of Rydberg electromagnetically induced transparency (EIT) and microwave induced Autler-Townes (AT) splitting in EIT windows are shown using optical pumping at D1 line. The enhanced sensitivity at 3.4 GHz with 0.3 GHz bandwidth can be realized, based on the enhanced EIT-AT spectrum. The experimental results show that in the stepped Rydberg EIT system, the spectral width of EIT and microwave field EIT-AT can be narrowed by optical pumping (OP), so the sensitivity of microwave electric field measurement can be improved. After optimizing the EIT amplitude and adding single-frequency microwaves, the sensitivity of the microwave electric field measurement observed by the AT splitting interval is improved by 1.3 times. This work provides a reference for utilizing atomic microwave detection.