Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Extending coherence time of macro-scale diamond magnetometer by dynamical decoupling with coplanar waveguide resonator

雄太 増山, Y. MASUYAMA, 皓介 水野, Kosuke Mizuno, 勇斗 小澤, Hayato Ozawa, 整 石綿, Hitoshi Ishiwata, 孝之 岩崎, T. Ohshima, 睦子 波多野, T. Iwasaki, Mutsuko Hatano, M. Hatano

Published Dec 1, 2018• 0 citations
OpenAlex

Related papers

Highly sensitive macro-scale diamond magnetometer operated by dynamical decoupling sequence with coplanar waveguide resonator

雄太 増山, Y. MASUYAMA, 皓介 水野 +11 more

•May 1, 2018•0 citations

Development of diamond quantum magnetometer module using coplanar waveguide

雄太 増山, Y. MASUYAMA, 孝之 岩崎 +4 more

•Feb 1, 2019•0 citations

Cross-type two-layer coplanar waveguide circuit toward spin-noise decoupling of ensemble NV centers in large-volume diamond

Yuki Kamitsubo, Y. MASUYAMA, T. Sekiguchi +5 more

The Japan Society of Applied Physics•Jan 28, 2020•0 citations

Extending coherence time of macro-scale diamond magnetometer by dynamical decoupling with coplanar waveguide resonator

Y. MASUYAMA, Kosuke Mizuno, Hayato Ozawa +5 more

Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in a diamond is limited by a number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve a highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4 × 10−3 mm3. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers. This system combined with a decoupling pulse sequence, XY16, extends the spin coherence time (T2) up to 27 times longer than that with a spin echo method. Consequently, we obtained an AC magnetic field sensitivity of 10.8 pt/Hz using the dynamical decoupling pulse sequence.

arXiv:1805.10725•Review of Scientific Instruments•Dec 1, 2018•34 citations

Dynamic analysis of atomic magnetometer and co-magnetometer

Shihu Wang, Linke Yu, Wei Wang

Physica B Condensed Matter•Dec 24, 2015•4 citations

Crossed two-layer coplanar-waveguide circuit for extending spin dephasing time T2* of ensemble NV centers in a bulk diamond

Y. Kamitsubo, T. Sekiguchi, Masuyama Yuta +10 more

The nitrogen-vacancy (NV) center in diamond is extensively studied for a next-generation high-sensitivity magnetometer. The DC magnetic sensitivity can be improved by extending the inhomogeneous spin dephasing time through suppressing the effects of inhomogeneous fluctuations or by increasing the number of effective NV centers through expanding the sensor volume. It has been demonstrated that strain-induced dephasing can be suppressed by double quantum (DQ) technique with two-tone microwaves (MW), and spin bath-induced dephasing can be suppressed by spin bath drive (SBD) technique with multi-tone radio-frequency (RF) to drive the P1 centers. To combine these T2* -extension techniques with a bulk diamond, it is necessary to apply MW and RF uniformly to the sample. A coplanar waveguide (CPW) circuit has been reported to be useful for uniform microwave irradiation to a bulk sample. In this study, we reports the newly designed and fabricated a cross-aligned two-layer CPW circuit.

•Dec 17, 2020•0 citations
Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in a diamond is limited by a number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve a highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4 × 10−3 mm3. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers. This system combined with a decoupling pulse sequence, XY16, extends the spin coherence time (T2) up to 27 times longer than that with a spin echo method. Consequently, we obtained an AC magnetic field sensitivity of 10.8 pt/Hz using the dynamical decoupling pulse sequence.
The nitrogen-vacancy (NV) center in diamond is extensively studied for a next-generation high-sensitivity magnetometer. The DC magnetic sensitivity can be improved by extending the inhomogeneous spin dephasing time through suppressing the effects of inhomogeneous fluctuations or by increasing the number of effective NV centers through expanding the sensor volume. It has been demonstrated that strain-induced dephasing can be suppressed by double quantum (DQ) technique with two-tone microwaves (MW), and spin bath-induced dephasing can be suppressed by spin bath drive (SBD) technique with multi-tone radio-frequency (RF) to drive the P1 centers. To combine these T2* -extension techniques with a bulk diamond, it is necessary to apply MW and RF uniformly to the sample. A coplanar waveguide (CPW) circuit has been reported to be useful for uniform microwave irradiation to a bulk sample. In this study, we reports the newly designed and fabricated a cross-aligned two-layer CPW circuit.