Phase sensitive protocol "iQdyne" for wid-field diamond magnetometry

皓介 水野, Kosuke Mizuno, 誠人 中島, M. Nakajima, 整 石綿, Hitoshi Ishiwata, 雄太 増山, Y. MASUYAMA, 孝之 岩崎, Takayuki Iwasaki, 睦子 波多野, Mutsuko Hatano

Published Feb 1, 2019• 0 citations
OpenAlex

Related papers

Characteristics of phase sensitive protocol “iQdyne” for diamond quantum magnetometry in wide field optics

皓介 水野, Kosuke Mizuno, 誠人 中島 +9 more

•Mar 1, 2019•0 citations

Phase sensitive quantum magnetometry imaging using emsemble NV center in diamond on wide field optics

皓介 水野, Kosuke Mizuno, 整 石綿 +7 more

•Jun 1, 2019•0 citations

Simultaneous amplitude and phase wide-field imaging of AC magnetic signal using diamond quantum magnetometry

皓介 水野, Kosuke Mizuno, 整 石綿 +7 more

•Dec 1, 2019•0 citations

Wide-field diamond magnetometry with millihertz frequency resolution and nanotesla sensitivity

Kosuke Mizuno, Makoto Nakajima, Hitoshi Ishiwata +3 more

Wide-field quantum magnetometry using nitrogen-vacancy (NV) center in diamond can be a breakthrough for a nuclear magnetic resonance (NMR) in a small volume, which is important for biological applications. Although the coherence time of the electron spin of the NV center results in a limited frequency resolution for diamond magnetometry in the range 10–100 kHz, recent studies have shown that a phase-sensitive protocol can circumvent this limit using a confocal setup. We proposed a new measurement protocol, “iQdyne,” which facilitates an improved frequency resolution of wide-field imaging, unencumbered by the coherence limit imposed by the NV center. We demonstrated wide-field magnetometry with a frequency resolution of 238 mHz and a magnetic sensitivity of 65 nT/Hz1/2, which are superior to those obtained using a conventional XY8-based technique, and showed the potential of the iQdyne protocol for the wide-field NMR imaging.

arXiv:1807.04444•AIP Advances•Dec 1, 2018•19 citations

Robust diamond-defect magnetometry

Johanna L. Miller

Physics Today•Jun 20, 2018•0 citations

Simultaneous wide-field imaging of phase and magnitude of AC magnetic signal using diamond quantum magnetometry

Kosuke Mizuno, Hitoshi Ishiwata, Y. MASUYAMA +2 more

Spectroscopic analysis of AC magnetic signal using diamond quantum magnetometry is a promising technique for inductive imaging. Conventional dynamic decoupling like XY8 provides a high sensitivity of an oscillating magnetic signal with intricate dependence on magnitude and phase, complicating high throughput detection of each parameter. In this study, a simple measurement scheme for independent and simultaneous detection of magnitude and phase is demonstrated by a sequential measurement protocol. Wide-field imaging experiment was performed for an oscillating magnetic field with approximately [Formula: see text]-squared observation area. Single pixel phase precision was [Formula: see text] for [Formula: see text] AC magnetic signal. Our method enables potential applications including inductive inspection and impedance imaging.

arXiv:2001.02374•Scientific Reports•Jul 14, 2020•31 citations
Wide-field quantum magnetometry using nitrogen-vacancy (NV) center in diamond can be a breakthrough for a nuclear magnetic resonance (NMR) in a small volume, which is important for biological applications. Although the coherence time of the electron spin of the NV center results in a limited frequency resolution for diamond magnetometry in the range 10–100 kHz, recent studies have shown that a phase-sensitive protocol can circumvent this limit using a confocal setup. We proposed a new measurement protocol, “iQdyne,” which facilitates an improved frequency resolution of wide-field imaging, unencumbered by the coherence limit imposed by the NV center. We demonstrated wide-field magnetometry with a frequency resolution of 238 mHz and a magnetic sensitivity of 65 nT/Hz1/2, which are superior to those obtained using a conventional XY8-based technique, and showed the potential of the iQdyne protocol for the wide-field NMR imaging.
Spectroscopic analysis of AC magnetic signal using diamond quantum magnetometry is a promising technique for inductive imaging. Conventional dynamic decoupling like XY8 provides a high sensitivity of an oscillating magnetic signal with intricate dependence on magnitude and phase, complicating high throughput detection of each parameter. In this study, a simple measurement scheme for independent and simultaneous detection of magnitude and phase is demonstrated by a sequential measurement protocol. Wide-field imaging experiment was performed for an oscillating magnetic field with approximately [Formula: see text]-squared observation area. Single pixel phase precision was [Formula: see text] for [Formula: see text] AC magnetic signal. Our method enables potential applications including inductive inspection and impedance imaging.